{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1193-6AM00-7AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1193-6AM00-7AA0","canonicalUrl":"https://aoctrl.com/siemens/6AG1193-6AM00-7AA0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1193-6AM00-7AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS ET 200SP BusAdapter BA 2xM12, based on 6ES7193-6AM00-0AA0, conformal coating, -40…+70 °C, 2x M12 push-pull sockets for PROFINET, D-coding.","salesMarkdown":"## Extended temperature BusAdapter for harsh environments The 6AG1193-6AM00-7AA0 is a SIPLUS ET 200SP BusAdapter BA 2xM12, the ruggedized sibling of the standard 6ES7193-6AM00-0AA0. This BusAdapter provides two M12 push-pull sockets with D-coding for PROFINET connectivity, fitting into the ET 200SP distributed I/O system. It is also compatible with standard M12 connectors, giving field wiring flexibility. ## Environmental resilience and coating The conformal coating per IPC-CC-830A Class A protects the PCB assembly against moisture, dust, and chemical attack. The unit is resistant to commercially available coolants and lubricants, including diesel and oil droplets in the air, and meets ANSI/ISA-71.04 level GX group A/B for corrosive gas environments. Protection against fouling per EN 60664-3 Type 1 is included. The temperature range depends on mounting orientation: vertical installation is limited to 50 °C max, while horizontal installation allows up to 70 °C. At altitudes above 2,000 m, the maximum ambient temperature must be derated by 10 K per 1,500 m increment up to 5,000 m. ## Physical fit and mounting The two M12 push-pull ports are D-coded for PROFINET. The push-pull mechanism allows tool-less mating and unmating, which speeds up panel wiring and reduces downtime during maintenance.","metaTitle":"6AG1193-6AM00-7AA0 SIPLUS ET 200SP BusAdapter 2xM12","metaDescription":"SIPLUS ET 200SP BusAdapter 2xM12 for PROFINET, based on 6ES7193-6AM00-0AA0 with conformal coating. Extended temp -40…+70 °C, 2 M12 push-pull ports.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Depth":"59 mm","Width":"20 mm","Height":"73.5 mm","Cu conductors":"100 m","Weight, approx.":"59 g","lifecycle_stage":"current","Number of M12 ports":"2","Vertical Installation, Max.":"50 °C; = Tmax","Vertical Installation, Min.":"-40 °C; = Tmin","Horizontal Installation, Max.":"70 °C; = Tmax","Horizontal Installation, Min.":"-40 °C; = Tmin (incl. condensation/frost)","Number of PROFINET interfaces":"1","Installation altitude above sea level, max.":"5 000 m","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/341e3518f97b4bb5550fbec63f57fa84.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1505970&mlfb=6AG1193-6AM00-7AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AG1193-6AM00-7AA0/alternatives.json"},"ai":{"faq":[{"question":"What is the difference between 6AG1193-6AM00-7AA0 and the standard 6ES7193-6AM00-0AA0?","answer":"The SIPLUS variant adds conformal coating and extends the operating temperature range to -40…+70 °C, compared to the standard part's narrower range. It also includes resistance to coolants, lubricants, and corrosive gases per ANSI/ISA-71.04."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1193-6AM00-7AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1193-6AM00-7AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}