{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1210-1PE21-2UL0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1210-1PE21-2UL0","canonicalUrl":"https://aoctrl.com/siemens/6AG1210-1PE21-2UL0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1210-1PE21-2UL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SINAMICS G120 Power Module, FSB frame, 7.5 kW, 400 V AC input, 27 A output, efficiency 0.97, IP20, internal air cooling.","salesMarkdown":"The Siemens 6AG1210-1PE21-2UL0 is a SINAMICS G120 Power Module in the FSB frame size, rated for 7.5 kW output. It delivers up to 27 A from a three-phase AC supply, with a full-load efficiency of 0.97. Designed to drive standard induction motors in variable-speed applications, this module requires an associated Control Unit (CU) to operate. ## Physical and environmental fit Mounts in a 292 × 100 × 165 mm envelope (H × W × D) with IP20 protection, so it belongs in a closed panel. Internal air cooling pushes 0.0092 m³/s through the heatsink; keep clearance around the module for airflow. Ambient operating range is -20 to 55 °C, and it will tolerate storage from -25 to 55 °C. For transport, the part can handle -40 to 70 °C. ## Protection and braking built in The module includes overload, short-circuit, ground-fault, overvoltage, and undervoltage protection as standard. For stopping heavy or vertical loads, it supports DC braking, compound braking, and resistance braking with an integrated brake chopper (optional on the larger FSGX frame, but the FSB chopper is internal). Stall and blocked-rotor protection are also present, and parameter locking prevents unauthorized changes. ## Sourcing reality — same part, different passport The 6AG1210-1PE21-2UL0 is a current-production Siemens SINAMICS G120 module.","metaTitle":"6AG1210-1PE21-2UL0 Siemens SINAMICS G120 Power Module FSB 7.","metaDescription":"Siemens SINAMICS G120 power module 6AG1210-1PE21-2UL0, FSB frame, 7.5 kW, 27 A output, efficiency 0.97, temp -20 to 55 °C. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Max.":"55 °C; = Tmax","Min.":"-20 °C; = Tmin","Depth":"165 mm","Width":"100 mm","title":"6AG1210-1PE21-2UL0","Height":"292 mm","Present":"No","Efficiency":"0.97","description":"SIPLUS G120 PM240-2 IP20-FSA-U-400V 7.5 kW based on 6SL3210-1PE21-8UL0 with conformal coating, -20…+50 °C, unfiltered with integrated braking chopper 380-480 V 3 AC +10/-10% 47-63 Hz power high overload: 5.5 kW at 200% 3 s,150% 57 s,100% 240 s power rating low overload: 7.5 kW at 150% 3 s,110% 57 s,100% 240 s 291x 100x 165 (HxWxD), design FSB, degree of protection IP20 without CU and operating unit released as of CU FW version V4.7 HF8","Brake design":"DC braking, compound braking, resistance braking with integrated brake chopper (for size FSGX optional)","Storage, max.":"55 °C","Storage, min.":"-25 °C","Cooling method":"Internal air cooling","Product version":"FSB 7.5 kW","Pulse frequency":"4 kHz","lifecycle_stage":"current","Cooling air flow":"0.0092 m³/s","Power loss, max.":"0.2 kW","Stall protection":"Yes","Parameter locking":"Yes","With blocked rotor":"Yes","Degree of pollution":"2 according to EN 61800-5-1","Overload protection":"Yes","Storage, max. [°F]":"131 °F; Class 1K3 acc. to EN 60721-3-1","Storage, min. [°F]":"-13 °F","Output current, max.":"27 A","Transportation, max.":"70 °C","Transportation, min.":"-40 °C","Transport, max. [°F]":"158 °F; Class 2K3 according to EN 60721-3-2","Transport, min. [°F]":"-40 °F","Type of input voltage":"AC","Overvoltage protection":"Yes","Design of the converter":"FSB","Ground-fault protection":"Yes","IP degree of protection":"IP20","Undervoltage protection":"Yes","Short-circuit protection":"Yes","Weight (without packaging)":"3 kg","Shock load during operation":"(15x g)/11 ms","Temperature monitor for motor":"Yes","Input current with low overload":"22.2 A","Output current without overload":"18 A","Input current with high overload":"19.8 A","Output current with low overload":"18 A","Sound pressure level (1 m), max.":"62 dB","Output current with high overload":"13.2 A","Temperature monitor for converter":"Yes","Cable length for motor, shielded, max.":"50 m","Emitted Active Power With Low Overload":"7.5 kW","Emitted Active Power With High Overload":"5.5 kW","Design of electrical connection of motor":"Plug-in screw terminals","Standard for EMC according to EN 61800-3":"the EMC product standard EN 61800-3 does not apply directly to a frequency inverter but to a PDS (Power Drive System), which comprises the complete circuitry, motor and cables in addition to the inverter","Touch protection according to EN 61800-5-1":"Assuming use as prescribed","Type of duty cycle duration with low overload":"1.1x rated output current (i.e. 110 % overload) for 57 s with a cycle time of 300 s; 1.5x rated output current (i.e. 150 % overload) for 3 s with a cycle time of 300 s","Type of duty cycle duration with high overload":"1.5x output current rating (i.e. 150 % overload) for 57 s with a cycle time of 300 s; 2x output current rating (i.e. 200 % overload) for 3 s with a cycle time of 300 s","Output voltage in relation to input voltage, max.":"95 %","Output voltage in relation to input voltage, min.":"0 %","Type of electrical connection for mains supply line":"Plug-in screw terminals","Design of electrical connection for the PE conductor":"Plug-in screw terminals","Connectable Cable Cross-Section For Mains Supply Line, Max.":"6 mm²","Connectable Cable Cross-Section For Mains Supply Line, Min.":"1.5 mm²","Connectable Cable Cross-Section For Motor Supply Line, Max.":"6 mm²","Connectable Cable Cross-Section For Motor Supply Line, Min.":"1.5 mm²","Installation altitude above sea level without derating, max.":"1 000 m","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Short-time withstand current (SCCR) of the entire control cabinet in accordance with UL 508A":"65 kA","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,413.51","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/122ac295d479e4a3e3dc3fe94638a391.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=505106&mlfb=6AG1210-1PE21-2UL0"},"ai":{"faq":[{"question":"What are the key temperature limits for the 6AG1210-1PE21-2UL0?","answer":"Operating range is -20 to 55 °C ambient. Storage range is -25 to 55 °C, and transport range is -40 to 70 °C."},{"question":"Does this power module include braking capability?","answer":"Yes. It supports DC braking, compound braking, and resistance braking with an integrated brake chopper (the chopper is standard on the FSB frame; the optional FSGX brake chopper is for larger drives)."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1210-1PE21-2UL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1210-1PE21-2UL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}