{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1210-1PE28-2UL0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1210-1PE28-2UL0","canonicalUrl":"https://aoctrl.com/siemens/6AG1210-1PE28-2UL0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1210-1PE28-2UL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SINAMICS G120C, FSE design, 45 kW converter, 150 A output current, 62.4 kVA, IP20, 26 kg.","salesMarkdown":"## Drive selection memo: 45 kW FSE converter with 150 A output The 6AG1210-1PE28-2UL0 is a current-production FSE design frequency inverter, rated for 45 kW motor power. It delivers 150 A continuous output current at 4 kHz pulse frequency and 62.4 kVA apparent power. Protections are comprehensive: ground-fault, short-circuit, overvoltage, undervoltage, overload, and stall — plus parameter locking to prevent unauthorized changes. The IP20 rating suits clean indoor panels; no condensation permitted. ## Environmental and mounting notes Operating ambient range -20 to 50 °C; derate above 40 °C per the thermal curve. Storage range -25 to 55 °C; transport down to -40 °C. Pollution degree 2 per EN 61800-5-1. IE2 efficiency class for the complete drive module (CDM). Brake chopper integrated for DC, compound, or resistance braking; optional for FSGX size.","metaTitle":"Siemens 6AG1210-1PE28-2UL0 SINAMICS G120C 45kW FSE Drive","metaDescription":"Current-production Siemens SINAMICS G120C converter, FSE design, 45 kW, 150 A output, IP20, 0.98 efficiency. Sourced to order; RFQ for availability.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Max.":"50 °C; = Tmax","Min.":"-20 °C; = Tmin","Depth":"237 mm","Width":"275 mm","title":"6AG1210-1PE28-2UL0","Height":"551 mm","Present":"No","Efficiency":"0.98","description":"SIPLUS G120 PM240-2 IP20-FSE-U-400V 45 kW based on 6SL3210-1PE28-8UL0 with conformal coating, -20…+50 °C, unfiltered with integrated braking chopper 380-480 V 3 AC +10/-20% 47-63 Hz power high overload: 37 kW at 200% 3 s,150% 57 s,100% 240 s power low overload: 45 kW at 150% 3 s,110% 57 s,100% 240 s 551x 275x 237 (HxWxD), design FSE degree of protection IP20 without CU and operating unit released as of CU FW version V4.7 HF8","Brake design":"DC braking, compound braking, resistance braking with integrated brake chopper (for size FSGX optional)","Storage, max.":"55 °C","Storage, min.":"-25 °C","Cooling method":"Internal air cooling","Operation, max.":"98 %","Product version":"FSE 45 kW","Pulse frequency":"4 kHz","lifecycle_stage":"current","Cooling air flow":"0.083 m³/s","Power loss, max.":"1.194 kW","Stall protection":"Yes","Parameter locking":"Yes","With blocked rotor":"Yes","Degree of pollution":"2 according to EN 61800-5-1","IE class of the CDM":"IE2","Overload protection":"Yes","Storage, max. [°F]":"131 °F; Class 1K3 acc. to EN 60721-3-1","Storage, min. [°F]":"-13 °F","Output current, max.":"150 A","Transportation, max.":"70 °C","Transportation, min.":"-40 °C","Apparent Power Output":"62.4 kVA","Transport, max. [°F]":"158 °F; Class 2K3 according to EN 60721-3-2","Transport, min. [°F]":"-40 °F","Type of input voltage":"AC","Overvoltage protection":"Yes","Design of the converter":"FSE","Ground-fault protection":"Yes","IP degree of protection":"IP20","Undervoltage protection":"Yes","Condensation permissible":"No","Short-circuit protection":"Yes","Weight (without packaging)":"26 kg","Shock load during operation":"(15x g)/11 ms","Temperature monitor for motor":"Yes","Input current with low overload":"86 A","Output current without overload":"90 A","Input current with high overload":"78 A","Output current with low overload":"90 A","Sound pressure level (1 m), max.":"70.6 dB","Output current with high overload":"75 A","Temperature monitor for converter":"Yes","Power loss of the CDM in standby mode":"32 W","Cable length for motor, shielded, max.":"200 m","Emitted Active Power With Low Overload":"45 kW","Cable length for braking resistor, max.":"10 m","Emitted Active Power With High Overload":"37 kW","Design of electrical connection of motor":"Screw terminals","Standard for EMC according to EN 61800-3":"the EMC product standard EN 61800-3 does not apply directly to a frequency inverter but to a PDS (Power Drive System), which comprises the complete circuitry, motor and cables in addition to the inverter","Active Power Output With Low Overload [Hp]":"60 hp","Touch protection according to EN 61800-5-1":"Assuming use as prescribed","Active Power Output With High Overload [Hp]":"50 hp","Type of duty cycle duration with low overload":"1.1x rated output current (i.e. 110 % overload) for 57 s with a cycle time of 300 s; 1.5x rated output current (i.e. 150 % overload) for 3 s with a cycle time of 300 s","Type of duty cycle duration with high overload":"1.5x output current rating (i.e. 150 % overload) for 57 s with a cycle time of 300 s; 2x output current rating (i.e. 200 % overload) for 3 s with a cycle time of 300 s","Output voltage in relation to input voltage, max.":"95 %","Output voltage in relation to input voltage, min.":"0 %","Power loss of the CDM at the operating point (0/25)":"406 W","Power loss of the CDM at the operating point (0/50)":"543 W","Type of electrical connection for mains supply line":"Screw terminals","Design of electrical connection for the PE conductor":"Screw terminals","Power loss of the CDM at the operating point (0/100)":"955 W","Power loss of the CDM at the operating point (50/25)":"424 W","Power loss of the CDM at the operating point (50/50)":"599 W","Power loss of the CDM at the operating point (90/50)":"674 W","Connectable conductor cross-section for AWG cables, max.":"2","Connectable conductor cross-section for AWG cables, min.":"8","Connectable Cable Cross-Section For Mains Supply Line, Max.":"70 mm²","Connectable Cable Cross-Section For Mains Supply Line, Min.":"25 mm²","Connectable Cable Cross-Section For Motor Supply Line, Max.":"70 mm²","Connectable Cable Cross-Section For Motor Supply Line, Min.":"25 mm²","Installation altitude above sea level without derating, max.":"1 000 m","Relative power loss of the CDM at the operating point (0/25)":"0.65 %","Relative power loss of the CDM at the operating point (0/50)":"0.87 %","Relative power loss of the CDM at the operating point (0/100)":"1.53 %","Relative power loss of the CDM at the operating point (50/25)":"0.68 %","Relative power loss of the CDM at the operating point (50/50)":"0.96 %","Relative power loss of the CDM at the operating point (90/50)":"1.08 %","Type of electrical connection for supply cable to braking resistor":"Screw terminals","Connectable cable cross-section for supply cable to braking resistor, max.":"35 mm²","Connectable cable cross-section for supply cable to braking resistor, min.":"10 mm²","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Short-time withstand current (SCCR) of the entire control cabinet in accordance with UL 508A":"65 kA","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/122ac295d479e4a3e3dc3fe94638a391.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1092025&mlfb=6AG1210-1PE28-2UL0"},"ai":{"faq":[{"question":"What is the maximum operating temperature?","answer":"50 °C."},{"question":"What is the minimum operating temperature?","answer":"-20 °C."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1210-1PE28-2UL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1210-1PE28-2UL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}