{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1210-1PE31-2AL0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1210-1PE31-2AL0","canonicalUrl":"https://aoctrl.com/siemens/6AG1210-1PE31-2AL0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1210-1PE31-2AL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SINAMICS G120, FSF frame, 75 kW, 220 A, 0.98 efficiency, IP20.","salesMarkdown":"The Siemens 6AG1210-1PE31-2AL0 is a SINAMICS G120 variable frequency drive in the FSF frame size, rated for 75 kW output power and delivering 220 A continuous current with 0.98 efficiency. The IP20 enclosure means it is panel-mount only—sized for controlling three-phase induction motors in pumps, fans, conveyors, and general duty applications. ## Panel fit and cooling At 708 mm high × 305 mm wide × 357 mm deep, the drive needs a generous backpanel opening, and internal air cooling demands 0.153 m³/s of airflow—plan for clearance around the heat sink. No condensation allowed, so locate away from washdown areas. ## Built-in protection and braking Comprehensive motor and system protection is integrated: stall, overload, ground-fault, short-circuit, overvoltage, and undervoltage. This single drive replaces the need for separate motor protection relays in most installations. The brake design includes DC and compound braking, with provision for an external resistor; the integrated brake chopper is standard for sizes up to FSGX.","metaTitle":"Siemens 6AG1210-1PE31-2AL0 SINAMICS G120, 220A, 75kW","metaDescription":"Siemens 6AG1210-1PE31-2AL0 SINAMICS G120 FSF drive, 75kW, 220A output, 0.98 efficiency, IP20. Current production. Available to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Max.":"50 °C; = Tmax","Min.":"-20 °C; = Tmin","Depth":"357 mm","Width":"305 mm","title":"6AG1210-1PE31-2AL0","Height":"708 mm","Present":"Yes","Efficiency":"0.98","description":"SIPLUS G120 PM240-2 IP20-FSF-A-400V 75 kW based on 6SL3210-1PE31-5AL0 with conformal coating, -20…+50 °C, with integrated class A filter with integrated braking chopper 380-480 V 3 AC +10/-20% 47-63 Hz power high overload: 55 kW at 200% 3 s,150% 57 s,100% 240 s power low overload: 75 kW at 150% 3 s,110% 57 s,100% 240 s 708x 305x 357 (HxWxD), FSF design, degree of protection IP20 without CU and operating unit released as of CU FW version V4.7 HF8","Brake design":"DC braking, compound braking, resistance braking with integrated brake chopper (for size FSGX optional)","Storage, max.":"55 °C","Storage, min.":"-25 °C","Cooling method":"Internal air cooling","Operation, max.":"98 %","Product version":"FSF 75 kW","Pulse frequency":"4 kHz","lifecycle_stage":"current","Cooling air flow":"0.153 m³/s","Power loss, max.":"1.787 kW","Stall protection":"Yes","Parameter locking":"Yes","With blocked rotor":"Yes","Degree of pollution":"2 according to EN 61800-5-1","IE class of the CDM":"IE2","Overload protection":"Yes","Storage, max. [°F]":"131 °F; Class 1K3 acc. to EN 60721-3-1","Storage, min. [°F]":"-13 °F","Output current, max.":"220 A","Transportation, max.":"70 °C","Transportation, min.":"-40 °C","Apparent Power Output":"100.46 kVA","Design of line filter":"Class A","Transport, max. [°F]":"158 °F; Class 2K3 according to EN 60721-3-2","Transport, min. [°F]":"-40 °F","Type of input voltage":"AC","Overvoltage protection":"Yes","Design of the converter":"FSF","Ground-fault protection":"Yes","IP degree of protection":"IP20","Undervoltage protection":"Yes","Condensation permissible":"No","Short-circuit protection":"Yes","Weight (without packaging)":"63 kg","Shock load during operation":"(15x g)/11 ms","Temperature monitor for motor":"Yes","Input current with low overload":"140 A","Output current without overload":"145 A","Input current with high overload":"117 A","Output current with low overload":"145 A","Sound pressure level (1 m), max.":"67.7 dB","Output current with high overload":"110 A","Temperature monitor for converter":"Yes","Power loss of the CDM in standby mode":"48.1 W","Cable length for motor, shielded, max.":"300 m","Emitted Active Power With Low Overload":"75 kW","Cable length for braking resistor, max.":"10 m","Emitted Active Power With High Overload":"55 kW","Design of electrical connection of motor":"M10 screw stud","Standard for EMC according to EN 61800-3":"the EMC product standard EN 61800-3 does not apply directly to a frequency inverter but to a PDS (Power Drive System), which comprises the complete circuitry, motor and cables in addition to the inverter","Active Power Output With Low Overload [Hp]":"100 hp","Touch protection according to EN 61800-5-1":"Assuming use as prescribed","Active Power Output With High Overload [Hp]":"75 hp","Type of duty cycle duration with low overload":"1.1x rated output current (i.e. 110 % overload) for 57 s with a cycle time of 300 s; 1.5x rated output current (i.e. 150 % overload) for 3 s with a cycle time of 300 s","Type of duty cycle duration with high overload":"1.5x output current rating (i.e. 150 % overload) for 57 s with a cycle time of 300 s; 2x output current rating (i.e. 200 % overload) for 3 s with a cycle time of 300 s","Output voltage in relation to input voltage, max.":"95 %","Output voltage in relation to input voltage, min.":"0 %","Power loss of the CDM at the operating point (0/25)":"586.5 W","Power loss of the CDM at the operating point (0/50)":"791.3 W","Type of electrical connection for mains supply line":"M10 screw stud","Design of electrical connection for the PE conductor":"M10 screw stud","Power loss of the CDM at the operating point (0/100)":"1 395.6 W","Power loss of the CDM at the operating point (50/25)":"621.2 W","Power loss of the CDM at the operating point (50/50)":"871.5 W","Power loss of the CDM at the operating point (90/50)":"987.7 W","Connectable conductor cross-section for AWG cables, min.":"4","Connectable Cable Cross-Section For Mains Supply Line, Max.":"120 mm²","Connectable Cable Cross-Section For Mains Supply Line, Min.":"35 mm²","Connectable Cable Cross-Section For Motor Supply Line, Max.":"120 mm²","Connectable Cable Cross-Section For Motor Supply Line, Min.":"35 mm²","Installation altitude above sea level without derating, max.":"1 000 m","Relative power loss of the CDM at the operating point (0/25)":"0.58 %","Relative power loss of the CDM at the operating point (0/50)":"0.79 %","Relative power loss of the CDM at the operating point (0/100)":"1.39 %","Relative power loss of the CDM at the operating point (50/25)":"0.62 %","Relative power loss of the CDM at the operating point (50/50)":"0.87 %","Relative power loss of the CDM at the operating point (90/50)":"0.98 %","Type of electrical connection for supply cable to braking resistor":"Screw terminals","Connectable cable cross-section for supply cable to braking resistor, max.":"70 mm²","Connectable cable cross-section for supply cable to braking resistor, min.":"25 mm²","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Short-time withstand current (SCCR) of the entire control cabinet in accordance with UL 508A":"65 kA","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/122ac295d479e4a3e3dc3fe94638a391.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1092026&mlfb=6AG1210-1PE31-2AL0"},"ai":{"faq":[{"question":"What are the key electrical ratings?","answer":"Rated output power is 75 kW, maximum output current is 220 A, and apparent output power is 100.46 kVA at 4 kHz pulse frequency."},{"question":"What is the operating temperature range?","answer":"Operating ambient range is -20°C to +50°C; storage range is -25°C to +55°C."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1210-1PE31-2AL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1210-1PE31-2AL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}