{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1210-1PE31-2UL0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1210-1PE31-2UL0","canonicalUrl":"https://aoctrl.com/siemens/6AG1210-1PE31-2UL0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1210-1PE31-2UL0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SINAMICS G120C, FSF frame, 6AG1210-1PE31-2UL0, 220 A output, 75 kW, IP20, integrated brake chopper.","salesMarkdown":"The 6AG1210-1PE31-2UL0 is an FSF version drive rated for 75 kW and 220 A output current. It delivers 100.46 kVA apparent power at 0.98 efficiency, IE2 class. The integrated brake chopper handles DC braking, compound braking, or resistance braking. For size FSGX it's optional, but on this FSF frame you get it as standard—one less external component to source for vertical-axis or high-inertia loads. ## Mounting and cooling No condensation allowed (the spec says that explicitly). Keep the panel dry; a small heater or breather drain is cheap insurance. Storage range is -25 °C to 55 °C—handling, not running, is what that governs. ## Protection features Ground-fault protection, overvoltage, undervoltage, short-circuit, and stall protection are all built in. Parameter locking stops unauthorized tweaks. Pulse frequency is 4 kHz; you can adjust it lower for less switching loss or higher for quieter motor operation, but that will increase derating above 50 °C.","metaTitle":"Siemens 6AG1210-1PE31-2UL0 Drive, 220 A, 75 kW","metaDescription":"Siemens SINAMICS G120C drive in active production. Output current 220 A max, 100.46 kVA, 75 kW, IP20. IE2 efficiency. Order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Max.":"50 °C; = Tmax","Min.":"-20 °C; = Tmin","Depth":"357 mm","Width":"305 mm","title":"6AG1210-1PE31-2UL0","Height":"708 mm","Present":"No","Efficiency":"0.98","description":"SIPLUS G120 PM240-2 IP20-FSF-U-400V 75 kW based on 6SL3210-1PE31-5UL0 with conformal coating, -20…+50 °C, unfiltered with integrated braking chopper 380-480 V 3 AC +10/-20% 47-63 Hz power high overload: 55 kW at 200% 3 s,150% 57 s,100% 240 s power low overload: 75 kW at 150% 3 s,110% 57 s,100% 240 s 708x 305x 357 (HxWxD), FSF design, degree of protection IP20 without CU and operating unit released as of CU FW version V4.7 HF8","Brake design":"DC braking, compound braking, resistance braking with integrated brake chopper (for size FSGX optional)","Storage, max.":"55 °C","Storage, min.":"-25 °C","Cooling method":"Internal air cooling","Operation, max.":"98 %","Product version":"FSF 75 kW","Pulse frequency":"4 kHz","lifecycle_stage":"current","Cooling air flow":"0.153 m³/s","Power loss, max.":"1.776 kW","Stall protection":"Yes","Parameter locking":"Yes","With blocked rotor":"Yes","Degree of pollution":"2 according to EN 61800-5-1","IE class of the CDM":"IE2","Overload protection":"Yes","Storage, max. [°F]":"131 °F; Class 1K3 acc. to EN 60721-3-1","Storage, min. [°F]":"-13 °F","Output current, max.":"220 A","Transportation, max.":"70 °C","Transportation, min.":"-40 °C","Apparent Power Output":"100.46 kVA","Transport, max. [°F]":"158 °F; Class 2K3 according to EN 60721-3-2","Transport, min. [°F]":"-40 °F","Type of input voltage":"AC","Overvoltage protection":"Yes","Design of the converter":"FSF","Ground-fault protection":"Yes","IP degree of protection":"IP20","Undervoltage protection":"Yes","Condensation permissible":"No","Short-circuit protection":"Yes","Weight (without packaging)":"57 kg","Shock load during operation":"(15x g)/11 ms","Temperature monitor for motor":"Yes","Input current with low overload":"140 A","Output current without overload":"145 A","Input current with high overload":"117 A","Output current with low overload":"145 A","Sound pressure level (1 m), max.":"67.7 dB","Output current with high overload":"110 A","Temperature monitor for converter":"Yes","Power loss of the CDM in standby mode":"48.1 W","Cable length for motor, shielded, max.":"300 m","Emitted Active Power With Low Overload":"75 kW","Cable length for braking resistor, max.":"10 m","Emitted Active Power With High Overload":"55 kW","Design of electrical connection of motor":"M10 screw stud","Standard for EMC according to EN 61800-3":"the EMC product standard EN 61800-3 does not apply directly to a frequency inverter but to a PDS (Power Drive System), which comprises the complete circuitry, motor and cables in addition to the inverter","Active Power Output With Low Overload [Hp]":"100 hp","Touch protection according to EN 61800-5-1":"Assuming use as prescribed","Active Power Output With High Overload [Hp]":"75 hp","Type of duty cycle duration with low overload":"1.1x rated output current (i.e. 110 % overload) for 57 s with a cycle time of 300 s; 1.5x rated output current (i.e. 150 % overload) for 3 s with a cycle time of 300 s","Type of duty cycle duration with high overload":"1.5x output current rating (i.e. 150 % overload) for 57 s with a cycle time of 300 s; 2x output current rating (i.e. 200 % overload) for 3 s with a cycle time of 300 s","Output voltage in relation to input voltage, max.":"95 %","Output voltage in relation to input voltage, min.":"0 %","Power loss of the CDM at the operating point (0/25)":"586.4 W","Power loss of the CDM at the operating point (0/50)":"791.2 W","Type of electrical connection for mains supply line":"M10 screw stud","Design of electrical connection for the PE conductor":"M10 screw stud","Power loss of the CDM at the operating point (0/100)":"1 395.3 W","Power loss of the CDM at the operating point (50/25)":"620.9 W","Power loss of the CDM at the operating point (50/50)":"870.5 W","Power loss of the CDM at the operating point (90/50)":"984.7 W","Connectable conductor cross-section for AWG cables, min.":"4","Connectable Cable Cross-Section For Mains Supply Line, Max.":"120 mm²","Connectable Cable Cross-Section For Mains Supply Line, Min.":"35 mm²","Connectable Cable Cross-Section For Motor Supply Line, Max.":"120 mm²","Connectable Cable Cross-Section For Motor Supply Line, Min.":"35 mm²","Installation altitude above sea level without derating, max.":"1 000 m","Relative power loss of the CDM at the operating point (0/25)":"0.58 %","Relative power loss of the CDM at the operating point (0/50)":"0.79 %","Relative power loss of the CDM at the operating point (0/100)":"1.39 %","Relative power loss of the CDM at the operating point (50/25)":"0.62 %","Relative power loss of the CDM at the operating point (50/50)":"0.87 %","Relative power loss of the CDM at the operating point (90/50)":"0.98 %","Type of electrical connection for supply cable to braking resistor":"Screw terminals","Connectable cable cross-section for supply cable to braking resistor, max.":"70 mm²","Connectable cable cross-section for supply cable to braking resistor, min.":"25 mm²","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Short-time withstand current (SCCR) of the entire control cabinet in accordance with UL 508A":"65 kA","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/122ac295d479e4a3e3dc3fe94638a391.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1092027&mlfb=6AG1210-1PE31-2UL0"},"ai":{"faq":[{"question":"What are the key electrical ratings of this drive?","answer":"Output current 220 A max, apparent power 100.46 kVA, efficiency 0.98, designed for 75 kW motor. IE2 efficiency class on the complete drive module. Pulse frequency 4 kHz, input voltage AC."},{"question":"What cooling does this drive require?","answer":"Internal air cooling with 0.153 m³/s airflow. Panel must be kept free of condensation and ambient below 50 °C. Maximum 98 % humidity non-condensing."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1210-1PE31-2UL0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1210-1PE31-2UL0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}