{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1212-1AD30-5XB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1212-1AD30-5XB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1212-1AD30-5XB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1212-1AD30-5XB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 6AG1212-1AD30-5XB0 PLC, PROFINET interface, 1 MB integrated work memory, 1024 byte I/O address space, FBD and LAD programming, 24 V DC supply, -40 to 70 °C.","salesMarkdown":"## PROFINET interface and memory sizing The 6AG1212-1AD30-5XB0 carries a PROFINET interface with autonegotiation and autocrossing, supporting shielded twisted-pair cable runs up to 100 m. This is the primary fieldbus link for this CPU — no PROFIBUS, MODBUS, or AS-Interface on board. Integrated work memory is 1 Mbyte, with the entire project held maintenance-free in the integral EEPROM. The bit memory address area is 4 kbyte, and the I/O address space is 1024 bytes each for inputs and outputs. ## Supply range and environmental limits Rated for 24 V DC supply with a permissible range of 20.4 V to 28.8 V. The operating temperature spans -40 °C to 70 °C, covering most industrial enclosures and cold storage lines. Approvals include cULus, CE mark, and FM approval — documentation for UL, CE, and FM compliance is provided with the unit. ## Programming and forcing capability Supports both FBD (Function Block Diagram) and LAD (Ladder Logic) programming languages. Forcing of variables is supported, covering inputs/outputs, memory bits, DBs, distributed I/Os, timers, and counters. PID controller function is built in, and the CPU supports 2-wire sensors with defined signal thresholds: 5 V DC at 1 mA for signal '0', 15 V DC at 2.5 mA for signal '1'.","metaTitle":"Siemens 6AG1212-1AD30-5XB0 PLC, PROFINET, 1 MB Work Memory","metaDescription":"Siemens 6AG1212-1AD30-5XB0 PLC with PROFINET interface, 1 MB integrated work memory, 1024 byte I/O address space. Supports FBD and LAD. cULus, CE, FM approved.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"FBD":"Yes","LAD":"Yes","24 V":"Permissible range: 20.4V to 28.8V","Max.":"70 °C","Min.":"-40 °C","Depth":"75 mm","Width":"90 mm","cULus":"Yes","Height":"100 mm","Inputs":"1 024 byte","MODBUS":"No","TCP/IP":"Yes","24 V DC":"Yes","CE mark":"Yes","Forcing":"Yes","Outputs":"1 024 byte","Overall":"15; dynamically","Present":"Yes; Entire project maintenance-free in the integral EEPROM","Voltage":"Yes","Isolated":"Yes","PROFIBUS":"No","As Server":"Yes","Supported":"Yes","Variables":"Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters","0 to +10 V":"Yes","Adjustable":"Yes","Expandable":"No","Integrated":"1 Mbyte","Backup time":"240 h; Typical","FM approval":"Yes","AS-Interface":"No","Autocrossing":"Yes","Number, max.":"4 kbyte; Size of bit memory address area","2-Wire Sensor":"Yes","For Signal \"0\"":"5 V DC at 1 mA","For Signal \"1\"":"15 V DC at 2.5 mA","Interface type":"PROFINET","PID controller":"Yes","Shielded, Max.":"100 m; shielded, twisted pair","Autonegotiation":"Yes","Parameterizable":"Single phase: 3 @ 100 kHz & 1 @ 30 kHz, differential: 3 @ 80 kHz & 1 @ 30 kHz","Weight, approx.":"370 g","Without Battery":"Yes","lifecycle_stage":"current","\"0\" To \"1\", Max.":"1 µs","\"1\" To \"0\", Max.":"5 µs","Power loss, typ.":"9 W","RJ 45 (Ethernet)":"Yes","Rated value (DC)":"24 V","Unshielded, Max.":"150 m","Fall height, max.":"0.3 m; five times, in product package","Source/sink input":"Yes","Inputs, adjustable":"1 kbyte","Number of counters":"4","On Lamp Load, Max.":"5 W","At \"0\" To \"1\", Max.":"12.8 ms","At \"0\" To \"1\", Min.":"0.2 ms","Outputs, adjustable":"1 kbyte","Programming package":"STEP 7 Basic V10.5","Between The Channels":"No","For Signal \"0\", Max.":"0.1 V; with 10 kOhm load","For Signal \"1\", Min.":"20 V","For Signal \"1\", Typ.":"1 mA","ISO-on-TCP (RFC1006)":"Yes","Inrush current, max.":"12 A; at 28.8 V DC","Frequency measurement":"Yes","RCM (formerly C-TICK)":"Yes","User-defined websites":"Yes","Controlled Positioning":"Yes","Number of alarm inputs":"4","PROFINET IO Controller":"Yes","Deviation per day, max.":"±60 s/month at 25 °C","IP degree of protection":"IP20","Limit frequency (pulse)":"100 kHz","Number of analog inputs":"2","Number of pulse outputs":"2","Number of relay outputs":"0","Status/control variable":"Yes","For Bit Operations, Typ.":"0.1 µs; / Operation","Number of analog outputs":"0","Number of blocks (total)":"DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used","Number of digital inputs":"8; Integrated","Short-circuit protection":"No; to be provided externally","Current consumption, max.":"1.2 A; 24 V DC","For Word Operations, Typ.":"12 µs; / Operation","Number of digital outputs":"6","With Resistive Load, Max.":"0.5 A","Between Different Circuits":"500 V DC between 24 V DC and 5 V DC","For Signal \"1\" Rated Value":"0.5 A","Hardware clock (real-time)":"Yes","Of Which High-Speed Outputs":"2; 100 kHz Pulse Train Output","Vertical Installation, Max.":"45 °C; = Tmax","Vertical Installation, Min.":"0 °C; = Tmin","Input resistance (0 to 10 V)":"≥100k ohms","Conversion time (per channel)":"625 µs","Horizontal Installation, Max.":"55 °C; = Tmax","Horizontal Installation, Min.":"0 °C; = Tmin","Test voltage at air discharge":"8 kV","Permissible Temperature Change":"5°C to 55°C, 3°C / minute","for backplane bus (5 V DC), max.":"1 000 mA; Max. 5 V DC for SM and CM","Counting frequency (counter) max.":"100 kHz","Integration time, parameterizable":"Yes","Supports protocol for PROFINET IO":"Yes","Test voltage at contact discharge":"6 kV","Between The Channels, In Groups Of":"2","Number of modules per system, max.":"3 comm. modules, 1 signal board, 2 signal modules","tested according to IEC 60068-2-27":"Yes; 15 g (m/s²), 11 ms pulse, 6 shocks in each of 3 axes","For Floating Point Arithmetic, Typ.":"18 µs; / Operation","Plug-in (SIMATIC Memory Card), max.":"24 Mbyte; with SIEMENS Memory Card","Potential separation digital inputs":"No; 500V AC for 1 minute","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","Potential separation digital outputs":"Yes","For Signal \"0\" Residual Current, Max.":"0.1 mA","Automatic Detection Of Transmission Rate":"Yes","Limit class A, for use in industrial areas":"Yes; Group 1","Limit class B, for use in residential areas":"Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011","Limitation of inductive shutdown voltage to":"L+ (-48 V)","Operation, tested according to IEC 60068-2-6":"Yes","Of The Pulse Outputs, With Resistive Load, Max.":"100 kHz","Of Which Inputs Usable For Technological Functions":"4; HSC (High Speed Counting)","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Resolution with overrange (bit including sign), max.":"10 bit","Retentive data area (incl. timers, counters, flags), max.":"2 048 byte"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/122ac295d479e4a3e3dc3fe94638a391.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=53224&mlfb=6AG1212-1AD30-5XB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AG1212-1AD30-5XB0/alternatives.json"},"ai":{"faq":[{"question":"Will 6AG1212-1AD30-5XB0 drop into a panel specified for 6ES7212-1AD30-0XB0?","answer":"The 6AG1212-1AD30-5XB0 shares the same form factor (90 mm width, 100 mm height, 75 mm depth) and PROFINET interface as the standard 6ES7212-1AD30-0XB0, but the 6AG variant includes the extended temperature range and additional approvals. Mechanical fit is identical; no rewiring is needed for the panel cutout or DIN rail."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1212-1AD30-5XB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1212-1AD30-5XB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}