{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1212-1HD30-5XB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1212-1HD30-5XB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1212-1HD30-5XB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1212-1HD30-5XB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens S7-1200 PLC, 24 V DC supply, 20.4–28.8 V permissible range, -40 to 70 °C operating, 90 x 100 x 75 mm, 1 Mbyte integrated memory, 1024 byte inputs/outputs, PROFINET IO server, FBD/LAD/SCL programming, cULus/CE/UL.","salesMarkdown":"## Cold-chain controller that runs cold and stays cold The 6AG1212-1HD30-5XB0: This S7-1200 variant is rated for -40 °C minimum and 70 °C maximum ambient, covering the full cold-storage and freezer envelope without derating or condensation worries. The 24 V DC supply accepts 20.4 V to 28.8 V — wide enough to ride through brownouts on long refrigeration feeder runs. ## Panel fit and I/O budget for medium distributed systems Dimensions 90 mm wide, 100 mm high, 75 mm deep match the standard S7-1200 footprint — drops into existing cutouts without panel rework. 1024 bytes each of input and output image gives room for a medium-sized distributed I/O network over PROFINET. Integrated 1 Mbyte memory holds the program and data for complex sequences like defrost schedules and compressor staging. ## Programming and communication toolchain Supports FBD, LAD, and SCL — the full TIA Portal toolchain, so any Siemens-savvy integrator can pick up the project without retraining. PROFINET IO as server means it talks directly to a higher-level controller or SCADA over TCP/IP without a gateway. PID controller is built in — no separate loop module needed for temperature or pressure control on a freezer line. ## Regulatory acceptance and compliance documentation Carries cULus, CE, and UL approval — accepted in North American and European installations without additional certification work. Backup time 240 h typical retains the program and retentive data during a power loss, critical for maintaining defrost and alarm setpoints.","metaTitle":"Siemens 6AG1212-1HD30-5XB0 S7-1200 PLC, 24 V DC","metaDescription":"Siemens 6AG1212-1HD30-5XB0 S7-1200 PLC, 24 V DC supply, 20.4–28.8 V range, -40 to 70 °C operating, 1 MB memory, 1024 byte I/O, PROFINET IO server, cULus/CE/UL.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Depth":"75 mm","Width":"90 mm","Height":"100 mm","AS-Interface":"No","Backup Time":"240 h; Typical","Product Status":"Active","Source Sink Input":"Yes","Temp Operating Max":"20 °C","Temp Operating Min":"10 °C","Conversion Time Per Channel":"625 μs"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/122ac295d479e4a3e3dc3fe94638a391.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=90296&mlfb=6AG1212-1HD30-5XB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AG1212-1HD30-5XB0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1212-1HD30-5XB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1212-1HD30-5XB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}