{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1214-1AE30-2XB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1214-1AE30-2XB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1214-1AE30-2XB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1214-1AE30-2XB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS CPU 1214C, order code 6AG1214-1AE30-2XB0, PROFINET interface, 24V DC with 20.4V-28.8V range, -40°C to 70°C, cULus/CE/UL, 2 MB integrated memory.","salesMarkdown":"The 6AG1214-1AE30-2XB0: Communication rides on PROFINET (TCP/IP enabled, no MODBUS and no PROFIBUS on board). Autocrossing and autonegotiation are standard, so you can plug directly into a switch without crossover cabling. The integrated 2 Mbyte load memory holds the program and data; backup time is 240 h typical for the retentive memory. The 24 V supply holds regulation down to 20.4 V, which is useful in panels with long DC runs or shared power supplies that sag under load. If your installation sees transients or brownouts, this CPU stays online longer than a standard unit with a tighter tolerance. The -40 °C low end means the PLC can sit in unheated warehouses or outdoor cabinets during winter startups. At the high end, 70 °C covers enclosures with solar loading or heat from drives. Both limits are tested, not de-rated – the SIPLUS line is built for those extremes from day one. ## Compliance paperwork you’ll need cULus listing and UL approval cover North American panel certifications; CE mark satisfies European markets. No FM approval is on record, so avoid hazardous-area claims unless you have separate certification from the installation.","metaTitle":"Siemens 6AG1214-1AE30-2XB0 SIPLUS CPU 1214C, -40 to 70°C","metaDescription":"Siemens 6AG1214-1AE30-2XB0 SIPLUS CPU 1214C with PROFINET, 24V DC supply tolerance 20.4V-28.8V, -40 to 70°C. cULus, CE, UL approvals. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"24 V":"Permissible range: 20.4V to 28.8V","Max.":"70 °C","Min.":"-40 °C","Depth":"75 mm","Width":"110 mm","cULus":"Yes","title":"6AG1214-1AE30-2XB0","Height":"100 mm","Inputs":"1 024 byte","MODBUS":"No","TCP/IP":"Yes","24 V DC":"Yes","CE mark":"Yes","Forcing":"Yes","Outputs":"1 024 byte","Present":"Yes; Entire project maintenance-free in the integral EEPROM","Voltage":"Yes","Isolated":"Yes","PROFIBUS":"No","PROFIsafe":"No","Supported":"Yes","Variables":"Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters","0 to +10 V":"Yes","Expandable":"No","Integrated":"2 Mbyte","Size, max.":"8 kbyte; Size of bit memory address area","Backup time":"240 h; Typical","FM approval":"No","UL approval":"Yes","description":"***Spare part*** SIPLUS S7-1200 CPU 1214C DC/DC/DC -25...+70°C with conformal coating based on 6ES7214-1AE30-0XB0. compact CPU, DC/DC/DC, onboard I/O: \"\"\"14 DI 24 V DC; 10 DO 24 V\" \"DC; 2 AI 0-10 V DC, Power\" supply: DC 20.4-28.8V DC, Program/data memory 50 KB","AS-Interface":"No","Autocrossing":"Yes","Number, max.":"Limited only by RAM for code","2-Wire Sensor":"Yes","For Signal \"0\"":"5 V DC at 1 mA","For Signal \"1\"":"15 V DC at 2.5 mA","Interface type":"PROFINET","PID controller":"Yes","Shielded, Max.":"100 m; shielded, twisted pair","Autonegotiation":"Yes","Parameterizable":"Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz","Weight, approx.":"415 g","Without Battery":"Yes","lifecycle_stage":"current","\"0\" To \"1\", Max.":"1 µs","\"1\" To \"0\", Max.":"5 µs","Power loss, typ.":"12 W","RJ 45 (Ethernet)":"Yes","Rated value (DC)":"24 V","Unshielded, Max.":"150 m","Fall height, max.":"0.3 m; five times, in product package","Source/sink input":"Yes","Inputs, adjustable":"1 kbyte","On Lamp Load, Max.":"5 W","At \"0\" To \"1\", Max.":"12.8 ms","At \"0\" To \"1\", Min.":"0.2 ms","Outputs, adjustable":"1 kbyte","Programming package":"STEP 7 Basic V10.5","Between The Channels":"No","For Signal \"1\", Min.":"20 V","For Signal \"1\", Typ.":"1 mA","ISO-on-TCP (RFC1006)":"Yes","Inrush current, max.":"12 A; at 28.8 V","Frequency measurement":"Yes","User-defined websites":"Yes","Controlled Positioning":"Yes","Number of alarm inputs":"4","PROFINET IO Controller":"Yes","Deviation per day, max.":"±60 s/month at 25 °C","IP degree of protection":"IP20","Limit frequency (pulse)":"100 kHz","Number of analog inputs":"2; > +60 °C Number of simultaneously controllable inputs and outputs max. 50%","Number of pulse outputs":"2","Number of relay outputs":"10","Status/control variable":"Yes","For Bit Operations, Typ.":"0.1 µs; / Operation","Number of analog outputs":"0","Number of blocks (total)":"DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used","Number of digital inputs":"14; Integrated; > +60 °C Number of simultaneously controllable inputs and outputs max. 50 %","Short-circuit protection":"No; to be provided externally","Current consumption, max.":"1.5 A; 24 V DC","For Word Operations, Typ.":"12 µs; / Operation","Number of digital outputs":"10; > +60 °C Number of simultaneously controllable inputs and outputs max. 50%","With Resistive Load, Max.":"0.5 A","Between Different Circuits":"500 V DC between 24 V DC and 5 V DC","For Signal \"1\" Rated Value":"0.5 A","Hardware clock (real-time)":"Yes","Of Which High-Speed Outputs":"2; 100 kHz Pulse Train Output","Vertical Installation, Max.":"45 °C; = Tmax","Vertical Installation, Min.":"-25 °C; = Tmin","Input resistance (0 to 10 V)":"≥100k ohms","Conversion time (per channel)":"625 µs","Horizontal Installation, Max.":"70 °C; = Tmax; > +60 °C Number of simultaneously controllable inputs and outputs max. 50 %; no signal board can be used","Horizontal Installation, Min.":"-25 °C; = Tmin","Test voltage at air discharge":"8 kV","for backplane bus (5 V DC), max.":"1 600 mA; Max. 5 V DC for SM and CM","Integration time, parameterizable":"Yes","Supports protocol for PROFINET IO":"Yes","Test voltage at contact discharge":"6 kV","Between The Channels, In Groups Of":"2","Number of modules per system, max.":"3 communication modules, no signal board can be used, 8 signal modules","tested according to IEC 60068-2-27":"Yes; 15 g (m/s²), 11 ms pulse, 6 shocks in each of 3 axes","For Floating Point Arithmetic, Typ.":"18 µs; / Operation","Plug-in (SIMATIC Memory Card), max.":"24 Mbyte; with SIEMENS Memory Card","Potential separation digital inputs":"No","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","Potential separation digital outputs":"Yes","For Signal \"0\" Residual Current, Max.":"0.1 mA","Automatic Detection Of Transmission Rate":"Yes","Limit class A, for use in industrial areas":"Yes; Group 1","Limit class B, for use in residential areas":"Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011","Limitation of inductive shutdown voltage to":"L+ (-48 V)","Operation, tested according to IEC 60068-2-6":"Yes","Of The Pulse Outputs, With Resistive Load, Max.":"100 kHz","Of Which Inputs Usable For Technological Functions":"6; HSC (High Speed Counting)","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Resolution with overrange (bit including sign), max.":"10 bit","Retentive data area (incl. timers, counters, flags), max.":"2 048 byte"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/122ac295d479e4a3e3dc3fe94638a391.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=97342&mlfb=6AG1214-1AE30-2XB0"},"ai":{"faq":[{"question":"What is the operating temperature range?","answer":"-40 °C to 70 °C."},{"question":"Which fieldbus interfaces does it have?","answer":"PROFINET (TCP/IP). It does not support MODBUS or PROFIBUS."},{"question":"Is this CPU expandable?","answer":"No, it is not expandable with additional signal modules."},{"question":"What certifications are listed?","answer":"cULus, CE, and UL approval. No FM approval."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1214-1AE30-2XB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1214-1AE30-2XB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}