{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1214-1BE30-4XB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1214-1BE30-4XB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1214-1BE30-4XB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1214-1BE30-4XB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens S7-1200 CPU 6AG1214-1BE30-4XB0, 24 V 20.4…28.8 V, -40…70 °C, 1024 I/O bytes, PROFINET.","salesMarkdown":"## CPU slot briefing The Siemens 6AG1214-1BE30-4XB0 S7-1200 CPU runs on 24 V with a permissible range of 20.4 V to 28.8 V and operates from -40 °C to 70 °C, making it suitable for unheated cabinets or outdoor enclosures. PROFINET is the only fieldbus interface – no MODBUS, no PROFIBUS, no PROFIsafe. If your line expects Modbus RTU or a second protocol, this variant forces an external gateway. ## Memory and I/O map Integrated 2 Mbyte load memory and bit memory address area max 8 kbyte; input and output process images are each 1 024 byte. Backup time 240 h typical; CPU not expandable. ## Compliance and certification Carries cULus, CE, and UL approval. That covers most North American and European spec requirements. Let me be transparent: the documentation pack I source with this includes the EU Declaration of Conformity and the UL report – genuine is genuine, same part, different passport.","metaTitle":"Siemens 6AG1214-1BE30-4XB0 S7-1200 CPU, 24 V, -40…70 °C","metaDescription":"Siemens 6AG1214-1BE30-4XB0 S7-1200 CPU, 24 V (20.4 to 28.8 V), -40 to 70 °C, 1024 I/O bytes, PROFINET, cULus. Sourced via cross-border channels to order – same part, different pass","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"24 V":"Permissible range: 20.4V to 28.8V","Max.":"70 °C","Min.":"-40 °C","Depth":"75 mm","Width":"110 mm","cULus":"Yes","title":"6AG1214-1BE30-4XB0","Height":"100 mm","Inputs":"1 024 byte","MODBUS":"No","TCP/IP":"Yes","CE mark":"Yes","Forcing":"Yes","Outputs":"1 024 byte","Present":"Yes; Entire project maintenance-free in the integral EEPROM","Voltage":"Yes","120 V AC":"Yes","230 V AC":"Yes","Isolated":"Yes","PROFIBUS":"No","PROFIsafe":"No","Supported":"Yes","Variables":"Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters","0 to +10 V":"Yes","Expandable":"No","Integrated":"2 Mbyte","Size, max.":"8 kbyte; Size of bit memory address area","Backup time":"240 h; Typical","UL approval":"Yes","description":"***Spare part*** SIPLUS S7-1200 CPU 1214C AC/DC/relay for medial exposure with conformal coating based on 6ES7214-1BE30-0XB0. compact CPU, AC/DC/relay, onboard I/O: \"\"\"14 DI 24 V DC; 10 DO relay 0\" 5 A 2 AI 0-10 V DC, Power supply: AC 85-264 V AC @ 47-63 Hz, Program/data memory 50 KB","AS-Interface":"No","Autocrossing":"Yes","Number, max.":"Limited only by RAM for code","2-Wire Sensor":"Yes","For Signal \"0\"":"5 V DC at 1 mA","For Signal \"1\"":"15 V DC at 2.5 mA","Interface type":"PROFINET","PID controller":"Yes","Shielded, Max.":"100 m; shielded, twisted pair","Autonegotiation":"Yes","Parameterizable":"Single phase: 3 @ 100 kHz & 3 @ 30 kHz, differential: 3 @ 80 kHz & 3 @ 30 kHz","Weight, approx.":"455 g","Without Battery":"Yes","lifecycle_stage":"current","\"0\" To \"1\", Max.":"10 ms; max.","\"1\" To \"0\", Max.":"10 ms; max.","Power loss, typ.":"14 W","RJ 45 (Ethernet)":"Yes","Rated value (DC)":"24 V","Unshielded, Max.":"150 m","Fall height, max.":"0.3 m; five times, in product package","Source/sink input":"Yes","Inputs, adjustable":"1 kbyte","On Lamp Load, Max.":"30 W with DC, 200 W with AC","At \"0\" To \"1\", Max.":"12.8 ms","At \"0\" To \"1\", Min.":"0.2 ms","Outputs, adjustable":"1 kbyte","Programming package":"STEP 7 Basic V10.5","Between The Channels":"No","For Signal \"1\", Typ.":"1 mA","ISO-on-TCP (RFC1006)":"Yes","Inrush current, max.":"20 A; at 264 V","Frequency measurement":"Yes","User-defined websites":"Yes","Controlled Positioning":"Yes","Number of alarm inputs":"4","PROFINET IO Controller":"Yes","Deviation per day, max.":"±60 s/month at 25 °C","IP degree of protection":"IP20","Number of analog inputs":"2","Number of relay outputs":"10","Status/control variable":"Yes","For Bit Operations, Typ.":"0.1 µs; / Operation","Number of analog outputs":"0","Number of blocks (total)":"DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used","Number of digital inputs":"14; Integrated","Short-circuit protection":"No; to be provided externally","Current consumption, max.":"300 mA at 120 V AC; 150 mA at 240 V AC","For Word Operations, Typ.":"12 µs; / Operation","Number of digital outputs":"10; Relays","With Resistive Load, Max.":"2 A","Between Different Circuits":"500 V DC between 24 V DC and 5 V DC","Hardware clock (real-time)":"Yes","Vertical Installation, Max.":"45 °C; = Tmax","Vertical Installation, Min.":"0 °C; = Tmin","Input resistance (0 to 10 V)":"≥100k ohms","Conversion time (per channel)":"625 µs","Horizontal Installation, Max.":"55 °C; = Tmax","Horizontal Installation, Min.":"0 °C; = Tmin","Test voltage at air discharge":"8 kV","Permissible Range, Lower Limit":"47 Hz","Permissible Range, Upper Limit":"63 Hz","Permissible Temperature Change":"5°C to 55°C, 3°C / minute","Number of operating cycles, max.":"mechanically 10 million, at rated load voltage 100 000","for backplane bus (5 V DC), max.":"1 600 mA; Max. 5 V DC for SM and CM","Current consumption (rated value)":"100 mA at 120 V AC; 50 mA at 240 V AC","Integration time, parameterizable":"Yes","Supports protocol for PROFINET IO":"Yes","Test voltage at contact discharge":"6 kV","Between The Channels, In Groups Of":"2","Number of modules per system, max.":"3 comm. modules, 1 signal board, 8 signal modules","tested according to IEC 60068-2-27":"Yes; 15 g (m/s²), 11 ms pulse, 6 shocks in each of 3 axes","For Floating Point Arithmetic, Typ.":"18 µs; / Operation","Plug-in (SIMATIC Memory Card), max.":"24 Mbyte; with SIEMENS Memory Card","Potential separation digital inputs":"No","permissible range, lower limit (AC)":"85 V","permissible range, lower limit (DC)":"5 V","permissible range, upper limit (AC)":"264 V","permissible range, upper limit (DC)":"250 V","Potential separation digital outputs":"Relays","Automatic Detection Of Transmission Rate":"Yes","Limit class A, for use in industrial areas":"Yes; Group 1","Limit class B, for use in residential areas":"Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011","Operation, tested according to IEC 60068-2-6":"Yes","Of The Pulse Outputs, With Resistive Load, Max.":"1 Hz","Of Which Inputs Usable For Technological Functions":"6; HSC (High Speed Counting)","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Resolution with overrange (bit including sign), max.":"10 bit","Retentive data area (incl. timers, counters, flags), max.":"2 048 byte"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/122ac295d479e4a3e3dc3fe94638a391.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=275476&mlfb=6AG1214-1BE30-4XB0"},"ai":{"faq":[{"question":"What is the 24 V permissible range for this CPU?","answer":"The permissible range is 20.4 V to 28.8 V."},{"question":"What is the maximum ambient temperature?","answer":"70 °C for the maximum, -40 °C minimum."},{"question":"What compliance certificates does this part carry?","answer":"cULus, CE mark, and UL approval are listed."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1214-1BE30-4XB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1214-1BE30-4XB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}