{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1215-1AG40-5XB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1215-1AG40-5XB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1215-1AG40-5XB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1215-1AG40-5XB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC S7-1200 (SIPLUS variant), 6AG1215-1AG40-5XB0, CPU with FBD/LAD/SCL, -40 to 70°C, PROFINET, 4MB memory.","salesMarkdown":"## What this CPU delivers in harsh environments The 6AG1215-1AG40-5XB0: Programming in FBD, LAD, or SCL means no re-engineering if your existing codebase uses any of those languages — the same TIA Portal project can target this variant directly. Communication covers PROFINET (with shared device support for multi-controller setups), MODBUS TCP, UDP, and PROFIBUS via the CM 1243-5 module. The CPU acts as both MODBUS client and server, which simplifies integration with drives, HMIs, or third-party systems. Analog inputs accept 0–10 V and 0–20 mA signals; these are isolated from the CPU supply, so a ground loop on a temperature transmitter won't couple noise into the logic side. ## Panel mounting and power Footprint is 130 mm wide, 100 mm high, 75 mm deep. Direct rail mount. Integrated 4 Mbyte memory holds code and data; watchdog time, retentive data backup, and real-time clock ride through a 480-hour typical backup battery interval. ## Signal integrity notes for analog channels The isolated input stage means field-signal ground and CPU ground can float relative to each other — a common scenario when the transmitter is on a separate DC rail. No floating ground loops, no common-mode noise on the 0–20 mA loop. Input forcing is available for commissioning: you can override the field reading and simulate a value to test downstream logic without crawling to the sensor. ## Sourcing this exact variant This is the SIPLUS extended-temperature version.","metaTitle":"Siemens 6AG1215-1AG40-5XB0 S7-1200 CPU, -40 to 70°C","metaDescription":"SIPLUS S7-1200 CPU for extreme environments. -40 to 70°C. FBD/LAD/SCL. PROFINET, MODBUS, isolated analog inputs. 4 MB memory. Quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":[],"specifications":{"Depth":"75 mm","Width":"130 mm","Height":"100 mm","IP Rating":"IP20","AS-Interface":"Yes","Backup Time":"480 h; Typical","Interface Type":"PROFINET","Product Status":"Active","Source Sink Input":"Yes","Temp Operating Max":"10 °C","Temp Operating Min":"-20 °C","Conversion Time Per Channel":"625 μs"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$679.45 – $1,812.10","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ff14b262f901c59a8b77dcd3629ccd0c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=567215&mlfb=6AG1215-1AG40-5XB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AG1215-1AG40-5XB0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1215-1AG40-5XB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1215-1AG40-5XB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}