{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1222-1BF32-2XB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1222-1BF32-2XB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1222-1BF32-2XB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1222-1BF32-2XB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS S7-1200 SM 1222, 6AG1222-1BF32-2XB0, 8 digital outputs, 24 V DC, 0.5 A per channel, -40 to 70 °C, IP20.","salesMarkdown":"## Module overview Each channel switches 0.5 A resistive or inductive at 24 V DC nominal (20.4 to 28.8 V DC permissible range). Backplane bus draws 120 mA at 5 V DC. Diagnostics for supply voltage and channel status are included; short-circuit protection must be provided externally. Module is IP20 and requires a front connector. ## Sourcing Standard lead times apply for this current-production Siemens SIPLUS module.","metaTitle":"Siemens 6AG1222-1BF32-2XB0 SIPLUS SM 1222, 8DO, 0.5A, -40...","metaDescription":"Siemens SIPLUS S7-1200 SM 1222 digital output module, 8 channels, 24 V DC, 0.5 A per channel, -40 to 70 °C, IP20, diagnostics. Currently in active production. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Digital Output Modules"],"specifications":{"Max.":"70 °C","Min.":"-40 °C","Depth":"75 mm","Width":"45 mm","title":"6AG1222-1BF32-2XB0","Height":"100 mm","Plastic":"Yes","description":"SIPLUS S7-1200 SM 1222 8DQ based on 6ES7222-1BF32-0XB0 with conformal coating, -40…+70 °C, start up -25 °C, digital output 8 DQ, 24 V DC, transistor 0.5 A","In Groups Of":"1","Shielded, Max.":"500 m","For Maintenance":"Yes","Weight, approx.":"180 g","lifecycle_stage":"current","\"0\" To \"1\", Max.":"50 µs","\"1\" To \"0\", Max.":"200 µs","Diagnostic alarm":"Yes","Power loss, typ.":"1.5 W","Rated value (DC)":"24 V","Unshielded, Max.":"150 m","Fall height, max.":"0.3 m; five times, in product package","On Lamp Load, Max.":"5 W","up to 50 °C, max.":"4 A; Current per mass","Diagnostics function":"Yes","For Signal \"0\", Max.":"0.1 V; with 10 kOhm load","For Signal \"1\", Min.":"20 V DC","At cold restart, min.":"-25 °C","IP degree of protection":"IP20","Required Front Connector":"Yes","Short-circuit protection":"No; to be provided externally","For Status Of The Outputs":"Yes","Number of digital outputs":"8","With Inductive Load, Max.":"0.5 A","With Resistive Load, Max.":"0.5 A","For Signal \"1\" Rated Value":"0.5 A","Monitoring the supply voltage":"Yes","from backplane bus 5 V DC, max.":"120 mA","Between The Channels, In Groups Of":"1","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","For Signal \"0\" Residual Current, Max.":"10 µA","Between The Channels And Backplane Bus":"500 V AC","Installation altitude above sea level, max.":"5 000 m","Limitation of inductive shutdown voltage to":"typ. (L+) -48 V","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$140.97 – $387.08","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/20b41bab092ac00911dc1679e98ebcfe.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=95175&mlfb=6AG1222-1BF32-2XB0"},"ai":{"faq":[{"question":"What is the operating temperature range?","answer":"The module is rated for -40 °C to 70 °C ambient operation."},{"question":"Does the module provide short-circuit protection?","answer":"No, short-circuit protection must be provided externally according to the specifications."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1222-1BF32-2XB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1222-1BF32-2XB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}