{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1222-1HF30-4XB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1222-1HF30-4XB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1222-1HF30-4XB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1222-1HF30-4XB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS S7-1200 6AG1222-1HF30-4XB0 digital output module, 8 relay outputs, 2 A per channel, IP20, -40 to 70 °C, 45 x 100 x 75 mm.","salesMarkdown":"## 8 relay outputs for S7-1200 remote I/O The Siemens 6AG1222-1HF30-4XB0 is a SIPLUS variant of the S7-1200 digital output module, delivering 8 relay outputs rated 2 A per channel for both resistive and inductive loads. It switches AC loads from 5 V AC to 250 V AC and DC loads from 5 V DC to 30 V DC, covering solenoid valves, contactor coils, and indicator lamps in a control cabinet. ## Output ratings and channel isolation Each relay output handles 2 A continuous on resistive or inductive loads, with a lamp load limit of 30 W on DC and 200 W on AC. The outputs are grouped in pairs with 750 V AC isolation between groups and between circuits, so you can mix load voltages on the same module without coupling faults. The module draws 120 mA from the backplane 5 V DC bus and 11 mA per energized relay coil from the load voltage L+ supply. There is no internal short-circuit protection — an external fuse or breaker per group is required. Transition times from 0→1 and 1→0 are both 10 ms maximum. ## Environmental range and approvals The IP20 enclosure suits clean, dry indoor panel environments. FM approval is listed, and the module carries diagnostic alarm and status indication per channel. Cable runs can reach 500 m shielded or 150 m unshielded.","metaTitle":"Siemens 6AG1222-1HF30-4XB0 Digital Output Module","metaDescription":"Siemens 6AG1222-1HF30-4XB0 SIPLUS S7-1200 digital output module with 8 relay outputs, 2 A per channel, IP20, -40 to 70 °C. Active lifecycle, available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Digital Output Modules"],"specifications":{"Max.":"70 °C","Min.":"-40 °C","Depth":"75 mm","Width":"45 mm","Height":"100 mm","Plastic":"Yes","FM approval":"Yes","In Groups Of":"2","Shielded, Max.":"500 m","For Maintenance":"Yes","Weight, approx.":"190 g","lifecycle_stage":"current","\"0\" To \"1\", Max.":"10 ms","\"1\" To \"0\", Max.":"10 ms","Diagnostic alarm":"Yes","Power loss, typ.":"4.5 W","Rated value (AC)":"5 V AC to 250 V AC","Rated value (DC)":"5 V DC to 30 V DC","Unshielded, Max.":"150 m","Fall height, max.":"0.3 m; five times, in product package","On Lamp Load, Max.":"30 W with DC, 200 W with AC","up to 50 °C, max.":"10 A; Current per mass","Between The Channels":"Relays","Diagnostics function":"Yes","IP degree of protection":"IP20","Number of relay outputs":"8","Required Front Connector":"Yes","Short-circuit protection":"No; to be provided externally","For Status Of The Outputs":"Yes","Number of digital outputs":"8","With Inductive Load, Max.":"2 A","With Resistive Load, Max.":"2 A","Between Different Circuits":"750 V AC for 1 minute","from load voltage L+, max.":"11 mA/relay coil","Permissible Temperature Change":"5°C to 55°C, 3°C / minute","from backplane bus 5 V DC, max.":"120 mA","Number of operating cycles, max.":"mechanically 10 million, at rated load voltage 100 000","Between The Channels, In Groups Of":"2","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","Between The Channels And Backplane Bus":"1 500 V AC for 1 minute","For Signal \"1\" Permissible Range, Max.":"2 A","Rated supply voltage of relay coil L+ (DC)":"24 V","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=240156&mlfb=6AG1222-1HF30-4XB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AG1222-1HF30-4XB0/alternatives.json"},"ai":{"faq":[{"question":"What is the difference between 6AG1222-1HF30-4XB0 and the standard 6ES7222-1HF30-0XB0?","answer":"The 6AG1222-1HF30-4XB0 is the SIPLUS extended-temperature variant of the standard S7-1200 output module."},{"question":"How do I get current pricing and availability for 6AG1222-1HF30-4XB0?","answer":"Submit an RFQ through the storefront. The module is sourced to order against your BOM quantity, with pricing and lead time confirmed at quote time."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1222-1HF30-4XB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1222-1HF30-4XB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}