{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1223-1BH30-4XB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1223-1BH30-4XB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1223-1BH30-4XB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1223-1BH30-4XB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS S7-1200, 6AG1223-1BH30-4XB0, 8 digital inputs and 8 outputs, 24 V DC, -40 to 70 °C, IP20, current production.","salesMarkdown":"The Siemens 6AG1223-1BH30-4XB0 is a SIPLUS S7-1200 digital I/O module – 8 inputs and 8 outputs, 24 V DC. It's the ruggedized variant that handles -40 to 70 °C ambient, so it's a go-to for freezer floors, hot conveyor tunnels, or outdoor cabinets. Lifecycle is current, meaning you can keep it on the shelf as a critical spare without worrying about last-time-buy deadlines. The temperature range is the reason to pick this over the standard version: -40 °C min and 70 °C max, so no derating in extreme environments. Input thresholds are standard S7-1200: signal \"1\" at 15 V DC, 2.5 mA; signal \"0\" below 5 V DC at 1 mA. Outputs handle a lamp load up to 5 W, and diagnostics are built in – alarm and status bits come standard, parameterizable for your fault-isolation needs. Power draw is a typical 2.5 W, and the module requires an external front connector (not included). Covers the bases for industrial approvals: cULus for North American panels, CE mark for European machinery, and FM approval for hazardous locations (non-incendive). IP20 enclosure means it lives inside a cabinet. No short-circuit protection onboard – provide external per-line fusing or electronic protection, as per Siemens guidelines.","metaTitle":"Siemens 6AG1223-1BH30-4XB0 S7-1200 Digital I/O, -40 to 70°C","metaDescription":"Siemens SIPLUS S7-1200 digital I/O module, 8DI/8DO, 24 V DC. Rated -40 to 70 °C. Active production. cULus, CE, FM approved. Source to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"Max.":"70 °C","Min.":"-40 °C","Depth":"75 mm","Width":"45 mm","cULus":"Yes","Alarms":"Yes","Height":"100 mm","CE mark":"Yes","Plastic":"Yes","FM approval":"Yes","In Groups Of":"1","For Signal \"0\"":"5 V DC at 1 mA","For Signal \"1\"":"15 V DC at 2.5 mA","Shielded, Max.":"500 m","For Maintenance":"Yes","Parameterizable":"Yes","Weight, approx.":"210 g","lifecycle_stage":"current","\"0\" To \"1\", Max.":"50 µs","\"1\" To \"0\", Max.":"200 µs","Diagnostic alarm":"Yes","Power loss, typ.":"2.5 W","Rated value (DC)":"24 V","Unshielded, Max.":"150 m","Fall height, max.":"0.3 m; five times, in product package","On Lamp Load, Max.":"5 W","up to 40 °C, max.":"8","up to 50 °C, max.":"4 A; Current per mass","Diagnostics function":"Yes","For Signal \"0\", Max.":"0.1 V; with 10 kOhm load","For Signal \"1\", Min.":"20 V DC","For Signal \"1\", Typ.":"4 mA","Type of input voltage":"DC","IP degree of protection":"IP20","For Status Of The Inputs":"Yes","Number of digital inputs":"8","Required Front Connector":"Yes","Short-circuit protection":"No; to be provided externally","For Status Of The Outputs":"Yes","Number of digital outputs":"8","With Resistive Load, Max.":"0.5 A","For Signal \"1\" Rated Value":"0.5 A","Monitoring the supply voltage":"Yes","Permissible Temperature Change":"5°C to 55°C, 3°C / minute","from backplane bus 5 V DC, max.":"145 mA","Between The Channels, In Groups Of":"1","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","For Signal \"0\" Residual Current, Max.":"10 µA","Between The Channels And Backplane Bus":"500 V AC","For Signal \"1\" Permissible Range, Max.":"0.5 A","from load voltage L+ (without load), max.":"4 mA; per channel","Limitation of inductive shutdown voltage to":"L+ (-48 V)","Product Function / Supply Voltage For Transmitters":"Yes","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","For Signal \"0\", Max. (Permissible Quiescent Current)":"1 mA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$599.53","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=212724&mlfb=6AG1223-1BH30-4XB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AG1223-1BH30-4XB0/alternatives.json"},"ai":{"faq":[{"question":"What are the temperature limits?","answer":"Rated for -40 °C minimum and 70 °C maximum ambient, allowing use in freezers or near ovens without derating."},{"question":"Which compliance marks does it carry?","answer":"cULus, CE mark, and FM approval are listed on the unit."},{"question":"Does it require a front connector?","answer":"Yes, the module needs a separate front connector for field wiring; it is not included with the module."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1223-1BH30-4XB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1223-1BH30-4XB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}