{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1223-1BL32-2XB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1223-1BL32-2XB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1223-1BL32-2XB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1223-1BL32-2XB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS S7-1200 SM 1223, 6AG1223-1BL32-2XB0, 16 digital inputs 24V DC, 16 digital outputs 24V DC 0.5A, parameterizable, diagnostic alarm, -40…70°C, IP20, 100x70x75 mm.","salesMarkdown":"The 6AG1223-1BL32-2XB0: Drops into the same slot as the 6ES7223-1BH32-0XB0; same wiring, same footprint. The only delta is the temperature range. Fast nickel beats slow dime – RFQ this if your line needs that extended temp envelope. Otherwise, the standard version moves faster. ## Delta vs 6ES7223-1BH32-0XB0 Parameterizable with diagnostic alarm; same footprint as standard variant. Current production – no end-of-life or last-time-buy notice on record. This is a standard Siemens catalog item, so supply runs steady through the distribution channel. If you're freezing a BOM that needs the extended range, lock this code in. ## Integration Notes Mounts on the standard S7-1200 rail; requires a front connector (order separately). Wiring: unshielded cable runs up to 150 m, shielded up to 500 m. Input switching: signal '0' at ≤5 V / 1 mA, signal '1' at ≥15 V / 2.5 mA. Outputs: 0.5 A per channel resistive or inductive, no internal short-circuit protection – fuse externally. Diagnostic alarm and status bits are parameterizable via TIA Portal. Module power draw 4.5 W typ.","metaTitle":"Siemens 6AG1223-1BL32-2XB0 SIPLUS S7-1200 SM 1223, -40 to 70","metaDescription":"Active-production SIPLUS digital I/O module with 16 inputs/16 outputs, rated -40 to 70°C. Parameterizable with diagnostics and alarms. Source via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"Max.":"70 °C","Min.":"-40 °C","Depth":"75 mm","Width":"70 mm","title":"6AG1223-1BL32-2XB0","Alarms":"Yes","Height":"100 mm","Plastic":"Yes","description":"SIPLUS S7-1200 SM 1223 16DI/16DQ based on 6ES7223-1BL32-0XB0 with conformal coating, -40…+70 °C, start up -25 °C, digital input/output 16 DI/16 DQ, 16 DI 24 V DC, sink/source, 16 DQ, transistor 0.5 A","In Groups Of":"1","For Signal \"0\"":"5 V DC at 1 mA","For Signal \"1\"":"15 V DC at 2.5 mA","Shielded, Max.":"500 m","For Maintenance":"Yes","Parameterizable":"Yes","Weight, approx.":"310 g","lifecycle_stage":"current","\"0\" To \"1\", Max.":"50 µs","\"1\" To \"0\", Max.":"200 µs","Diagnostic alarm":"Yes","Power loss, typ.":"4.5 W","Rated value (DC)":"24 V","Unshielded, Max.":"150 m","Fall height, max.":"0.3 m; five times, in product package","On Lamp Load, Max.":"5 W","up to 40 °C, max.":"16","up to 50 °C, max.":"8 A; Current per mass","Diagnostics function":"Yes","For Signal \"0\", Max.":"0.1 V; with 10 kOhm load","For Signal \"1\", Min.":"20 V DC","For Signal \"1\", Typ.":"4 mA","At cold restart, min.":"-25 °C","Type of input voltage":"DC","IP degree of protection":"IP20","For Status Of The Inputs":"Yes","Number of digital inputs":"16","Required Front Connector":"Yes","Short-circuit protection":"No; to be provided externally","For Status Of The Outputs":"Yes","Number of digital outputs":"16","With Inductive Load, Max.":"0.5 A","With Resistive Load, Max.":"0.5 A","For Signal \"1\" Rated Value":"0.5 A","from backplane bus 5 V DC, max.":"185 mA","Between The Channels, In Groups Of":"1","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","For Signal \"0\" Residual Current, Max.":"10 µA","Between The Channels And Backplane Bus":"500 V AC","For Signal \"1\" Permissible Range, Max.":"0.5 A","from load voltage L+ (without load), max.":"4 mA; per channel","Installation altitude above sea level, max.":"5 000 m","Limitation of inductive shutdown voltage to":"L+ (-48 V)","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Product Function / Supply Voltage For Transmitters":"Yes","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","For Signal \"0\", Max. (Permissible Quiescent Current)":"1 mA","Resistant to commercially available coolants and lubricants":"Yes","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$426.72 – $1,138.58","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f8b1813c7f4c082f3fc94286fa2191a4.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=430248&mlfb=6AG1223-1BL32-2XB0"},"ai":{"faq":[{"question":"What is the closest functional second-source?","answer":"The standard 6ES7223-1BH32-0XB0 is the direct counterpart; same I/O count, same footprint, same wiring. The key difference is the temperature range: this SIPLUS variant covers -40°C to 70°C, while the standard version does not."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1223-1BL32-2XB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1223-1BL32-2XB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}