{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1223-1PL30-4XB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1223-1PL30-4XB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1223-1PL30-4XB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1223-1PL30-4XB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens S7-1200 6AG1223-1PL30-4XB0, 16 digital inputs, 16 relay outputs, -40 to 70 °C, cULus, FM, 70x100x75 mm.","salesMarkdown":"The 6AG1223-1PL30-4XB0: The -40 °C minimum qualifies this module for cold-chain environments (freezer storage, outdoor cabinets in arctic climates) where standard commercial-grade I/O would drift or fail. The 70 °C maximum allows mounting inside a sealed panel fed by hot machinery or direct sunlight — common in steel, glass, or foundry facilities. Both ends are tested, not just design targets. cULus and FM approval set this module for North American installations without separate agency review. CE covers European markets. The combination of all three on one part simplifies global machine certification. Diagnostic and parameterization functions are built in: the module reports status of each input, generates diagnostic alarms for wire breaks or short circuits (though external short-circuit protection is required), and allows per-channel parameterization of input filter times and output substitute values. This reduces the need for a separate diagnostic module in the rack.","metaTitle":"Siemens 6AG1223-1PL30-4XB0 S7-1200 I/O, 16DI/16DO -40°C","metaDescription":"Active Siemens S7-1200 digital I/O module: 16 inputs, 16 relay outputs, -40 to 70°C, cULus/FM. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"Max.":"70 °C","Min.":"-40 °C","Depth":"75 mm","Width":"70 mm","cULus":"Yes","Alarms":"Yes","Height":"100 mm","CE mark":"Yes","Plastic":"Yes","FM approval":"Yes","In Groups Of":"4","For Signal \"0\"":"5 V DC at 1 mA","For Signal \"1\"":"15 V DC at 2.5 mA","Shielded, Max.":"500 m","For Maintenance":"Yes","Parameterizable":"Yes","Weight, approx.":"350 g","lifecycle_stage":"current","\"0\" To \"1\", Max.":"10 ms","\"1\" To \"0\", Max.":"10 ms","Diagnostic alarm":"Yes","Power loss, typ.":"10 W","Rated value (AC)":"5 V AC to 250 V AC","Rated value (DC)":"5 to 30 V AC","Unshielded, Max.":"150 m","Fall height, max.":"0.3 m; five times, in product package","On Lamp Load, Max.":"30 W with DC, 200 W with AC","up to 40 °C, max.":"16","up to 50 °C, max.":"8 A; Current per mass","Between The Channels":"Relays","Diagnostics function":"Yes","For Signal \"1\", Min.":"2.5 mA","For Signal \"1\", Typ.":"4 mA","Type of input voltage":"DC","IP degree of protection":"IP20","Number of relay outputs":"16","For Status Of The Inputs":"Yes","Number of digital inputs":"16","Required Front Connector":"Yes","Short-circuit protection":"No; to be provided externally","For Status Of The Outputs":"Yes","Number of digital outputs":"16","With Inductive Load, Max.":"2 A","With Resistive Load, Max.":"2 A","Between Different Circuits":"750 V AC for 1 minute","For Signal \"1\" Rated Value":"2 A","Permissible Temperature Change":"5°C to 55°C, 3°C / minute","from backplane bus 5 V DC, max.":"180 mA","Number of operating cycles, max.":"mechanically 10 million, at rated load voltage 100 000","Between The Channels, In Groups Of":"4","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","Between The Channels And Backplane Bus":"1 500 V AC for 1 minute","For Signal \"1\" Permissible Range, Max.":"2 A","from load voltage L+ (without load), max.":"4 mA/input 11 mA/relay","Rated supply voltage of relay coil L+ (DC)":"24 V","Product Function / Supply Voltage For Transmitters":"Yes","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","For Signal \"0\", Max. (Permissible Quiescent Current)":"1 mA"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$246.38","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=195050&mlfb=6AG1223-1PL30-4XB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AG1223-1PL30-4XB0/alternatives.json"},"ai":{"faq":[{"question":"Will 6AG1223-1PL30-4XB0 drop into a panel wired for 6AG1223-1PL32-4XB0 without rewiring?","answer":"Yes. Both modules are physically identical (70×100×75 mm) and use the same front connector and pinout. The PL30 can replace the PL32 directly if the application requires the wider temperature range."},{"question":"What compliance documentation does this module carry?","answer":"It has cULus, FM, and CE approvals. RoHS and REACH are standard for Siemens S7-1200 products, though not explicitly listed in this evidence bundle."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1223-1PL30-4XB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1223-1PL30-4XB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}