{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1308-2FL10-4AA3","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1308-2FL10-4AA3","canonicalUrl":"https://aoctrl.com/siemens/6AG1308-2FL10-4AA3","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1308-2FL10-4AA3","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 6AG1308-2FL10-4AA3, compact managed industrial Ethernet switch, CLI, SSH, SNMP, 10/100/1000 Mbit/s, 125x120x124 mm.","salesMarkdown":"## Compact managed switch for industrial Ethernet networks The Siemens 6AG1308-2FL10-4AA3 is a compact managed industrial Ethernet switch supporting 10/100/1000 Mbit/s transfer rates. It provides command-line interface (CLI), SSH, SNMP v1/v2/v3, HTTP, HTTPS, and numerous other management protocols for configuration and monitoring. Dimensions are 125 mm high, 120 mm wide, and 124 mm deep, fitting a compact DIN-rail or wall-mount footprint. Designed for control cabinets and automation networks requiring managed switching with full protocol support. Rated for industrial environments with KC approval and MIB support. Sourced to order against RFQ; confirm current availability for your BOM line.","metaTitle":"Siemens 6AG1308-2FL10-4AA3 Managed Switch, CLI, 10/100/1000","metaDescription":"Industrial Ethernet switch with CLI, SSH, SNMP, HTTP, and compact 125x120x124 mm design. Supports 10/100/1000 Mbit/s. RFQ for lead time.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"CLI":"Yes","CoS":"Yes","DCP":"Yes","FTP":"Yes","NTP":"No","SSH":"Yes","STP":"Yes","GMRP":"Yes","HTTP":"Yes","LACP":"Yes","LLDP":"Yes","MSTP":"No","RMON":"Yes","RSTP":"Yes","SNTP":"Yes","TFTP":"Yes","BOOTP":"Yes","Depth":"124 mm","HTTPS":"Yes","Width":"120 mm","C-PLUG":"Yes","Design":"compact","Height":"125 mm","SysLog":"Yes","Telnet":"Yes","SNMP v1":"Yes","SNMP v2":"Yes","SNMP v3":"Yes","STP/RSTP":"Yes","DHCP client":"Yes","KC approval":"Yes","MIB support":"Yes","SMTP server":"Yes","VLAN dynamic":"Yes","Transfer Rate":"10 Mbit/s, 100 Mbit/s, 1000 Mbit/s","Wall Mounting":"Yes","DHCP Option 66":"Yes","DHCP Option 67":"Yes","DHCP Option 82":"Yes","Port Mirroring":"Yes","ACL - MAC-based":"Yes","Ring Redundancy":"Yes","SICLOCK support":"Yes","TRAPs via email":"Yes","at DC / maximum":"0.1 A","lifecycle_stage":"current","Error Statistics":"Yes","Fastening Method":"When used in shipbuilding, installation on a 35 mm standard mounting rail is not permitted.","For Power Supply":"4-pole terminal block","Port Diagnostics":"Yes","Passive Listening":"Yes","VLAN - port based":"Yes","Broadcast Blocking":"Yes","at DC / rated value":"24 V","protection class IP":"IP30","19-Inch Installation":"No","ACL - port/MAC-based":"Yes","IEEE 802.1x (radius)":"Yes","S7-300 rail mounting":"Yes","Security Information":"Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action(e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. For more information about industrial security, visit http://www.siemens.com/industrialsecurity. To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com. (V3.4)","Web-Based Management":"Yes","For Signaling Contact":"2-pole terminal block","PROFINET IO diagnosis":"Yes","Germanische Lloyd (GL)":"No","Statistics Packet Type":"Yes","statistics Packet Size":"Yes","IGMP (snooping/querier)":"Yes","Det Norske Veritas (DNV)":"No","For Emitted Interference":"EN 61000-6-4 (Class A)","Nippon Kaiji Kyokai (NK)":"No","RSTP big network support":"Yes","according to IEC 81346-2":"KF","redundancy procedure STP":"Yes","For Interference Immunity":"EN 61000-6-2","IEEE 1588 profile default":"No","configuration with STEP 7":"Yes","number of VLANs / maximum":"255","redundancy procedure MSTP":"No","redundancy procedure RSTP":"Yes","Polski Rejestr Statkow (PRS)":"No","Standard / For Hazardous Zone":"EN 60079-0 : 2006, EN 60079-15: 2005, II 3 G Ex nA II T4 KEMA 07 ATEX 0145X","according to IEC 81346-2:2019":"KFE","protocol / is supported / GVRP":"Yes","35 mm top hat DIN rail mounting":"Yes","Supply Voltage / 1 / Rated Value":"18 ... 32 V","power loss [W] / 1 / rated value":"9.6 W","Lloyds Register of Shipping (LRS)":"No","Product Function / Switch-Managed":"Yes","Broadcast/Multicast/Unicast Limiter":"Yes","Cascading In Cases Of Star Topology":"any (depending only on signal propagation time)","number of VLANs - dynamic / maximum":"255","High Speed Redundancy Protocol (HRP)":"Yes","conformity according to EN 60721-3-3":"Yes; Class 3S4 incl. sand, dust; *","conformity according to EN 60721-3-6":"Yes; Class 6S3 incl. sand, dust; *","French marine classification society (BV)":"No","Type Of Voltage / 1 / Of The Supply Voltage":"DC","For Network Components Or Terminal Equipment":"8","American Bureau of Shipping Europe Ltd. (ABS)":"No","railway application in accordance with EN 50155":"No","railway application in accordance with EN 50124-1":"No","Ambient Temperature / During Storage And Transport":"-40 ... +70 °C","Type Of Voltage Supply / Redundant Power Supply Unit":"No","media redundancy protocol (MRP) with redundancy manager":"Yes","high speed redundancy protocol (HRP) with redundancy manager":"Yes","high speed redundancy protocol (HRP) with standby redundancy":"Yes","Chemical Resistance / To Commercially Available Cooling Lubricants":"Yes; incl. airborne diesel and oil droplets","Cascading In The Case Of A Redundant Ring / At Reconfiguration Time Of <\\~0.3\\~S":"50","Ambient Condition / Relating To Ambient Temperature - Air Pressure - Installation Altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/203c9c19c3b013d5e24b74274efeae55.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=77109&mlfb=6AG1308-2FL10-4AA3","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AG1308-2FL10-4AA3/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1308-2FL10-4AA3","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1308-2FL10-4AA3 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}