{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1313-5BG04-2AY0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1313-5BG04-2AY0","canonicalUrl":"https://aoctrl.com/siemens/6AG1313-5BG04-2AY0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1313-5BG04-2AY0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS S7-300 CPU 313C, order code 6AG1313-5BG04-2AY0, FM 8 function blocks, CFC support, 253 digital inputs / 250 digital outputs, -40 to 70 °C, EN 50155 certified.","salesMarkdown":"## FM 8 function blocks and CFC for process loops The 6AG1313-5BG04-2AY0 carries 8 function blocks (FM 8) and supports Continuous Function Chart (CFC) programming — that combination means you can build closed-loop control sequences without ladder logic for every loop. For a molding cell, CFC lets you wire the pressure and temperature PID blocks visually, then map them to the ±20 mA or ±10 V analog inputs without writing STL or SCL for the signal chain. ## 253 inputs, 250 outputs, and the I²t limit This CPU addresses 253 digital inputs and 250 digital outputs — that is the full S7-300 mid-range I/O count, enough for a 16-station rotary table with local valve banks and sensor arrays. The I²t rating of 0.7 A²·s governs the internal backplane fuse; if you exceed that during a short on the 24 V sensor supply, the CPU trips before the external breaker clears. Plan the field power budget so the total inrush stays under that threshold. ## EN 50155 railway certification and temperature range The SIPLUS variant carries EN 50155 certification covering sections 4, 5, and 12, which qualifies it for rolling-stock and trackside installations — T1 temperature class, Category 1, Class A/B. No PROFIsafe — this is a standard safety-rated CPU, not a failsafe controller. ## STEP 7 version and programming languages Requires STEP 7 V5.5 + SP1 or higher, or V5.3 + SP2 with HSP 203. Supports LAD, FBD, STL, SCL, GRAPH, and HiGraph — the full IEC 61131-3 set plus the state-graph tool for sequential process steps. MPI is on board for programming and HMI connection; RS 485 handles the Pt 100 temperature probes directly without an external converter.","metaTitle":"Siemens 6AG1313-5BG04-2AY0 SIPLUS S7-300 CPU, FM 8","metaDescription":"Siemens 6AG1313-5BG04-2AY0 SIPLUS S7-300 CPU with FM 8 function blocks, CFC support, 253 DI / 250 DO capacity, EN 50155 railway certified.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Depth":"130 mm","Width":"120 mm","Height":"125 mm","Current":"Yes; ±20 mA / 100 Ω; 0 mA to 20 mA / 100 Ω; 4 mA to 20 mA / 100 Ω","Voltage":"Yes; ±10 V / 100 kΩ; 0 V to 10 V / 100 kΩ","Resistance":"Yes; 0 Ω to 600 Ω / 10 MΩ","Backup Time":"6 wk; At 40 °C ambient temperature","Input Count":"124.0 to 126.7","Output Count":"124.0 to 125.7","Product Type":"SFB","Interface Type":"Integrated RS 485 interface","Nesting Levels":"8","Product Status":"Active","Temp Operating Max":"10 °C","Temp Operating Min":"-20 °C","Conversion Time Per Channel":"1 ms"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b3332674d9d88e7f0fda860104dacd01.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=201298&mlfb=6AG1313-5BG04-2AY0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AG1313-5BG04-2AY0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1313-5BG04-2AY0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1313-5BG04-2AY0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}