{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1314-6CH04-7AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1314-6CH04-7AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1314-6CH04-7AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1314-6CH04-7AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS S7-300 CPU, 6AG1314-6CH04-7AB0, ruggedized variant with FM 8, -40 to 70 °C, ATEX, supports CFC/FBD/LAD/SCL/STL/GRAPH.","salesMarkdown":"## What this SIPLUS CPU is and where you'd use it The Siemens 6AG1314-6CH04-7AB0 is a SIPLUS version of the S7-314 CPU, built for extended temperature environments and hazardous-area installations. It carries FM 8, ATEX certification, and supports all major S7-300 programming languages: CFC, FBD, LAD, SCL, STL, GRAPH, and HiGraph. Communication is via Profibus DP through a CP card — MPI is not available on this variant. The CPU handles 244 bytes each of input and output data, and supports routing only with an active interface. For STEP 7 integration, you need V5.5 + SP1 or higher, or V5.3 + SP2 with HSP 203. If your existing project was built on a standard S7-314, verify the firmware and version compatibility before swapping. ## Mounting and panel fit – same footprint as the standard 314 This SIPLUS CPU shares the standard S7-300 form factor: 120 mm wide, 125 mm high, 130 mm deep. It clips onto the same DIN rail and backplane as any standard S7-300 CPU. If your panel was wired for a 6ES7314-1AF10-0AB0, this drops in mechanically without rewiring — same rack slot, same backplane connector. The extended temperature range and ATEX rating will require updated panel documentation (type examination certificate). Confirm that the enclosure's IP rating and thermal management still match the SIPLUS ambient limits.","metaTitle":"Siemens 6AG1314-6CH04-7AB0 SIPLUS S7-300 CPU, FM 8, -40-70°C","metaDescription":"Siemens 6AG1314-6CH04-7AB0 SIPLUS S7-300 CPU with FM 8, extended temperature -40 to 70 °C, ATEX certified. Supports CFC, FBD, LAD, SCL, STL, GRAPH. Sourced to order – RFQ required.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"FM":"8","CFC":"Yes","FBD":"Yes","I2t":"0.7 A²·s","LAD":"Yes","MPI":"No","SCL":"Yes","STL":"Yes","ATEX":"Yes","DPV1":"No","Max.":"70 °C","Min.":"-40 °C","Type":"SFB","Depth":"130 mm","GRAPH":"Yes","Width":"120 mm","title":"6AG1314-6CH04-7AB0","Height":"125 mm","Inputs":"244 byte","Number":"1","Preset":"10","Pt 100":"Yes","RS 485":"Yes","STEP 7":"Yes; STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203","via CP":"4","CE mark":"Yes","CP, LAN":"10","CP, PtP":"8","Current":"Yes; ±20 mA / 100 Ω; 0 mA to 20 mA / 100 Ω; 4 mA to 20 mA / 100 Ω","Forcing":"Yes","Outputs":"244 byte","Overall":"12","Present":"Yes","Routing":"Yes; Only with active interface","Voltage":"Yes; ±10 V / 100 kΩ; 0 V to 10 V / 100 kΩ","GSD file":"The latest GSD file is available on the Internet (http://www.siemens.com/profibus-gsd)","Isolated":"Yes","0 to 10 V":"Yes","As Client":"Yes; Via CP and loadable FB","As Server":"Yes","HiGraph®":"Yes","PROFIsafe":"No","Retentive":"Yes; Must be restarted at each restart","Supported":"Yes; via CP and loadable FC","Variables":"Inputs, outputs, memory bits, DB, times, counters","0 to +10 V":"Yes","0 to 20 mA":"Yes","Adjustable":"Yes; From 10 to 499","Expandable":"No","Integrated":"1","Resistance":"Yes; 0 Ω to 600 Ω / 10 MΩ","Size, max.":"256 byte","Backup time":"6 wk; At 40 °C ambient temperature","Command set":"see instruction list","Granularity":"1 h","KC approval":"Yes","Lower Limit":"48 Ω","Racks, max.":"4","Rated value":"3 ms","STEP 7 Lite":"No","SYNC/FREEZE":"Yes","Single step":"Yes","UL approval":"Yes","Upper Limit":"4 kΩ","description":"SIPLUS S7-300 CPU 314C-2DP based on 6ES7314-6CH04-0AB0 with conformal coating, -25…+70 °C, compact CPU with MPI, 24 DI/16 DQ, 4 AI, 2 AQ, 1 Pt100, 4 high-speed counters (60 kHz), integrated DP interface, integrated power supply 24 V DC, work memory 192 KB, front connector (2x 40-pole) and Micro Memory Card required","Equidistance":"Yes","For Uprating":"No","Inputs, max.":"244 byte","Number, max.":"see instruction list","PROFINET CBA":"No","Status block":"Yes; Up to 2 simultaneously","in AS, slave":"No","to DP, slave":"Yes","0 To 600 Ohms":"Yes","2-Wire Sensor":"Yes","4 mA to 20 mA":"Yes","Analog inputs":"752 to 761","Current, max.":"50 mA; Permanent","Outputs, max.":"244 byte","Plug-in (MMC)":"Yes","in AS, master":"Yes","to DP, master":"Yes; With DP slave only slave clock","to MPI, slave":"Yes","-10 V to +10 V":"Yes","Analog outputs":"752 to 755","Digital inputs":"124.0 to 126.7","For Signal \"0\"":"-3 to +5V","For Signal \"1\"":"+15 to +30 V","Interface type":"Integrated RS 485 interface","Nesting levels":"8","PID controller":"Yes","Shielded, Max.":"200 m","to MPI, master":"Yes","Can Be Read Out":"Yes","Digital outputs":"124.0 to 125.7","Inputs, default":"128 byte","Parameterizable":"Yes; by software","Range of values":"0 to 2^31 hours (when using SFC 101)","Weight, approx.":"680 g","Without Battery":"Yes; Program and data","lifecycle_stage":"current","-20 mA to +20 mA":"Yes","Block encryption":"Yes; With S7 block Privacy","Isochronous mode":"No","Of Which Central":"250","Outputs, default":"128 byte","Power loss, typ.":"13 W","Rated value (DC)":"24 V","S7 communication":"Yes; Only server, configured on one side","Unshielded, Max.":"600 m","PROFIBUS DP slave":"Yes","Repeat rate, min.":"1 s","Address area, max.":"32","For Inductive Load":"0.5 ms","For Resistive Load":"0.6 ms","Forcing, variables":"Inputs, outputs","Inputs, adjustable":"2 048 byte","Number of counters":"4; See \"Technological Functions\" manual","On Lamp Load, Max.":"100 Hz","PROFIBUS DP master":"Yes","PROFINET IO Device":"No","Per Priority Class":"16","Retentivity preset":"Yes","Usable For Routing":"4; max.","up to 40 °C, max.":"2 A","up to 60 °C, max.":"2 A; 1.5 A @ > 60 °C","At \"0\" To \"1\", Max.":"8 µs; Minimum pulse width/minimum pause between pulses at maximum counting frequency","Data record routing":"Yes","For Capacitive Load":"1 ms","Number/Number range":"0","Outputs, adjustable":"2 048 byte","PG/OP communication":"Yes","Plug-in (MMC), max.":"8 Mbyte","Programming package":"STEP 7 V5.5 + SP1 or higher or STEP 7 V5.3 + SP2 or higher with HSP 203","Between The Channels":"No","For Signal \"1\", Min.":"L+ (-0.8 V)","For Signal \"1\", Typ.":"8 mA","Inrush current, typ.":"5 A","EAC (formerly Gost-R)":"Yes","Frequency measurement":"Yes","Isolation tested with":"600 V DC","Measurement principle":"Actual value encryption (successive approximation)","Number of breakpoints":"4","Number of startup OBs":"1; OB 100","RCM (formerly C-TICK)":"Yes","Retentivity available":"Yes; MB 0 to MB 255","Controlled Positioning":"Yes","Modules per rack, max.":"8; In rack 3 max. 7","PROFINET IO Controller":"No","Resistance thermometer":"Yes; Pt 100 / 10 MΩ","Retentivity adjustable":"Yes; via non-retain property on DB","S7 basic communication":"No","System functions (SFC)":"see instruction list","Deviation per day, max.":"10 s; Typ.: 2 s","For Voltage Measurement":"Yes","Limit frequency (pulse)":"2.5 kHz","Number of analog inputs":"5","Number of entries, max.":"500","Number of pulse outputs":"4; Pulse width modulation up to 2.5 kHz (see \"Technological Functions\" Manual)","Status/control variable":"Yes","Transmission rate, max.":"12 Mbit/s","User data per job, max.":"180 kbyte; With PUT/GET","Counting frequency, max.":"60 kHz","For Bit Operations, Typ.":"0.06 µs","Number of DPV1 alarm OBs":"3; OB 55, 56, 57","Number of GD loops, max.":"8","Number of analog outputs":"2","Number of blocks (total)":"1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used.","Number of clock memories":"8; 1 memory byte","Number of digital inputs":"24","Number of free cycle OBs":"1; OB 1","Number of time alarm OBs":"1; OB 10","Of Which Powerfail-Proof":"100; Only the last 100 entries are retained","Per Priority Class, Max.":"32 kbyte; Max. 2048 bytes per block","Response threshold, typ.":"1 A","Short-circuit protection":"Yes; Clocked electronically","Size of GD packets, max.":"22 byte","integrated channels (AI)":"5; 4x current/voltage, 1x resistance","integrated channels (AO)":"2","integrated channels (DI)":"24","integrated channels (DO)":"16","For Word Operations, Typ.":"0.12 µs","Global data communication":"No","Input resistance (Pt 100)":"10 MΩ","Number of DP slaves, max.":"124","Number of delay alarm OBs":"2; OB 20, 21","Number of digital outputs":"16","Number of variables, max.":"10","Point-to-point connection":"No","With Inductive Load, Max.":"0.5 Hz","With Resistive Load, Max.":"100 Hz","Automatic Baud Rate Search":"Yes; only with passive interface","For Resistance Thermometer":"Pt 100","For Signal \"1\" Rated Value":"500 mA","Hardware clock (real-time)":"Yes","Number of GD packets, max.":"8","Number of frequency meters":"4; up to 60 kHz (see \"Technological Functions\" manual)","With Current Outputs, Max.":"300 Ω","With Voltage Outputs, Min.":"1 kΩ","from load voltage L+, max.":"50 mA","Controlling a digital input":"Yes","Number of RS 422 interfaces":"0","Number of RS 485 interfaces":"2; MPI and PROFIBUS DP","Number of process alarm OBs":"1; OB 40","Of Which High-Speed Outputs":"4; Notice: You cannot connect the fast outputs of your CPU in parallel","Process diagnostic messages":"Yes","Reverse polarity protection":"No","S7 communication, as client":"No","S7 communication, as server":"Yes","usable for OP communication":"11","usable for PG communication":"11","Input resistance (0 to 10 V)":"100 kΩ","Retentive And Synchronizable":"Yes","System function blocks (SFB)":"see instruction list","Conversion time (per channel)":"1 ms","Input resistance (0 to 20 mA)":"100 Ω","Number of PROFINET interfaces":"0","additional within an error OB":"4","reserved for OP communication":"1","reserved for PG communication":"1","Common mode interference, min.":"40 dB","Number of cyclic interrupt OBs":"4; OB 32, 33, 34, 35","For Redundant Control Of A Load":"Yes","For voltage/current measurement":"4","Number of expansion units, max.":"3","Number of synchronous error OBs":"2; OB 121, 122","Of Which Status Variables, Max.":"30","Electrical input frequency, max.":"400 Hz","For Fixed Point Arithmetic, Typ.":"0.16 µs","Input resistance (0 to 600 ohms)":"10 MΩ","Input resistance (4 mA to 20 mA)":"100 Ω","Number of asynchronous error OBs":"5; OB 80, 82, 85, 86, 87","Of Which Control Variables, Max.":"14","User data per address area, max.":"32 byte","Current consumption (rated value)":"880 mA","Integration time, parameterizable":"Yes; 16.6 / 20 ms","Time constant of the input filter":"0.38 ms","usable for S7 basic communication":"8","Between The Channels, In Groups Of":"8","Crosstalk between the inputs, min.":"60 dB","Potential separation analog inputs":"Yes; common for analog I/O","Crosstalk between the outputs, min.":"60 dB","For Floating Point Arithmetic, Typ.":"0.59 µs","For Signal \"1\" Minimum Load Current":"5 mA","Input resistance (-20 mA to +20 mA)":"100 Ω","Potential separation analog outputs":"Yes; common for analog I/O","Potential separation digital inputs":"Yes","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","reserved for S7 basic communication":"0","Activation/deactivation of DP slaves":"Yes","Number of GD packets, receiver, max.":"8","Potential separation digital outputs":"Yes","Voltages at the outputs towards MANA":"16 V; Permanent","Current output, no-load voltage, max.":"14 V","For Signal \"0\" Residual Current, Max.":"0.5 mA","Output current of the interface, max.":"200 mA","adjustable for OP communication, max.":"11","adjustable for OP communication, min.":"1","adjustable for PG communication, max.":"11","adjustable for PG communication, min.":"1","Between The Channels And Backplane Bus":"Yes","For Current Output Two-Wire Connection":"Yes","For Signal \"1\" Permissible Range, Max.":"0.6 A","For Signal \"1\" Permissible Range, Min.":"5 mA","For Voltage Output Two-Wire Connection":"Yes; Without compensation of the line resistances","Status indicator digital input (green)":"Yes","Current, relative to input range, (+/-)":"0.8 %; Linearity error ±0.06 %","For Voltage Output Four-Wire Connection":"No","Number of GD packets, transmitter, max.":"8","Number of entries readable in RUN, max.":"499","Status indicator digital output (green)":"Yes","Voltage, relative to input range, (+/-)":"0.8 %; Linearity error ±0.06 %","Behavior of the clock following POWER-ON":"Clock continues running after POWER OFF","Current, relative to output range, (+/-)":"0.8 %","Mains/voltage failure stored energy time":"5 ms","Number of industrial Ethernet interfaces":"0","Voltage output, short-circuit protection":"Yes","Voltage, relative to output range, (+/-)":"0.8 %","from load voltage L+ (without load), max.":"80 mA","Resistance, relative to input range, (+/-)":"0.8 %; Linearity error ±0.2 %","With Current Outputs, Inductive Load, Max.":"0.1 mH","simultaneously active Alarm-S blocks, max.":"300","Installation altitude above sea level, max.":"5 000 m","Limitation of inductive shutdown voltage to":"L+ (-48 V)","User program protection/password protection":"Yes","Voltage output, short-circuit current, max.":"55 mA","With Voltage Outputs, Capacitive Load, Max.":"0.1 µF","adjustable for S7 basic communication, max.":"8","adjustable for S7 basic communication, min.":"0","For Current Measurement As 2-Wire Transducer":"Yes; with external supply","For Current Measurement As 4-Wire Transducer":"Yes","Size of GD packet (of which consistent), max.":"22 byte","User data per job (of which consistent), max.":"240 byte; as server","Of The Pulse Outputs, With Resistive Load, Max.":"2.5 kHz","Current consumption (in no-load operation), typ.":"150 mA","Integrated Function Blocks (Closed-Loop Control)":"Yes; PID controller (see \"Technological Functions\" manual)","For resistance/resistance thermometer measurement":"1","Linearity error (relative to output range), (+/-)":"0.15 %","Of Which Inputs Usable For Technological Functions":"16","Temperature error (relative to input range), (+/-)":"0.006 %/K","Direct data exchange (slave-to-slave communication)":"Yes","For Resistance Measurement With Two-Wire Connection":"Yes; Without compensation of the line resistances","Permissible Quiescent Current (2-Wire Sensor), Max.":"1.5 mA","Temperature error (relative to output range), (+/-)":"0.01 %/K","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","For Resistance Measurement With Four-Wire Connection":"No","Number of login stations for message functions, max.":"12; Depending on the configured connections for PG/OP and S7 basic communication","Resolution with overrange (bit including sign), max.":"12 bit","Data management on MMC (after last programming), min.":"10 a","For Resistance Measurement With Three-Wire Connection":"No","No-load voltage for resistance-type transmitter, typ.":"3.3 V","Technical unit for temperature measurement adjustable":"Yes; Degrees Celsius / degrees Fahrenheit / Kelvin","Resistance thermometer, relative to input range, (+/-)":"0.8 %","Behavior of the clock following expiry of backup period":"the clock continues at the time of day it had when power was switched off","Retentive data area (incl. timers, counters, flags), max.":"64 kbyte","Basic execution time of the module (all channels released)":"1 ms","External Protection For Power Supply Lines (Recommendation)":"Miniature circuit breaker, type C; min. 2 A; miniature circuit breaker type B, min. 4 A","Constant measurement current for resistance-type transmitter, typ.":"1.25 mA","Interference voltage suppression for interference frequency f1 in Hz":"50 / 60 Hz","Permissible Input Current For Current Input (Destruction Limit), Max.":"50 mA; Permanent","Permissible Input Current For Voltage Input (Destruction Limit), Max.":"0.5 mA; Permanent","Permissible Input Voltage For Current Input (Destruction Limit), Max.":"5 V; Permanent","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"30 V; Permanent","Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-)":"0.1 %","Number of DP slaves that can be simultaneously activated/deactivated, max.":"8","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.06 %","Repeat accuracy in steady state at 25 °C (relative to output range), (+/-)":"0.06 %","Series mode interference (peak value of interference < rated value of input range), min.":"30 dB","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2dacb7775fab71f2b8de89b2a13f7142.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=251110&mlfb=6AG1314-6CH04-7AB0"},"ai":{"faq":[{"question":"Does this module support CFC (Continuous Function Chart)?","answer":"Yes, CFC is supported, along with FBD, LAD, SCL, STL, GRAPH, and HiGraph."},{"question":"What certifications does this CPU carry?","answer":"It carries CE marking and ATEX certification for hazardous areas."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1314-6CH04-7AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1314-6CH04-7AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}