{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1322-1BL00-2AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1322-1BL00-2AA0","canonicalUrl":"https://aoctrl.com/siemens/6AG1322-1BL00-2AA0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1322-1BL00-2AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens S7-1200 SIPLUS SM 1222, 6AG1322-1BL00-2AA0, 8-channel digital output module, 24 VDC, 2 A per channel, -40 to 70 °C, EN 50155.","salesMarkdown":"## Current production, no last-time-buy watch Approvals include CE, UL (E239877), KC, EAC, RCM, and EN 50155. The module is isolation-tested at 500 V DC between channel groups. Power loss is 6.6 W typical.","metaTitle":"Siemens 6AG1322-1BL00-2AA0 S7-1200 SIPLUS SM 1222, 70°C","metaDescription":"SIPLUS digital output module for S7-1200. 8 outputs, 2 A per channel, -40 to 70°C. EN 50155 rail certified. Active production. Source via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Digital Output Modules"],"specifications":{"Max.":"70 °C","Min.":"-40 °C","Depth":"120 mm","Width":"40 mm","title":"6AG1322-1BL00-2AA0","Alarms":"No","Height":"125 mm","CE mark":"Yes","EN 50155":"Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B, EN 50155:2007 (see SIOS entry 109755985)","Wire-break":"No","KC approval":"Yes","Lower Limit":"48 Ω","UL approval":"Yes; File E239877","Upper Limit":"4 kΩ","description":"SIPLUS S7-300 SM 322 32DQ 40-pole based on 6ES7322-1BL00-0AA0 with conformal coating, -25…+70 °C, digital output isolated, 32 DQ, 24 V DC, 0.5 A, 1x 40-pole, total current 4 A/group (16 A/module)","For Uprating":"No","Short-circuit":"No","Shielded, Max.":"1 000 m","Weight, approx.":"260 g","lifecycle_stage":"current","\"0\" To \"1\", Max.":"100 µs","\"1\" To \"0\", Max.":"500 µs","Diagnostic alarm":"No","Power loss, typ.":"6.6 W","Rated value (DC)":"24 V","Unshielded, Max.":"600 m","On Lamp Load, Max.":"10 Hz","up to 40 °C, max.":"2 A","up to 60 °C, max.":"3 A","up to 70 °C, max.":"2 A","Fuse OK FSG (green)":"No","Between The Channels":"Yes","Diagnostics function":"No","For Signal \"1\", Min.":"L+ (-0.8 V)","Group error SF (red)":"No","Missing Load Voltage":"No","EAC (formerly Gost-R)":"Yes","Isolation tested with":"500 V DC","RCM (formerly C-TICK)":"Yes","Required Front Connector":"40-pin","Response threshold, typ.":"1 A","Short-circuit protection":"Yes; Electronic","Number of digital outputs":"32","With Resistive Load, Max.":"100 Hz","For Signal \"1\" Rated Value":"0.5 A","Controlling a digital input":"Yes","Rated load voltage PWR (green)":"No","Channel fault indicator F (red)":"No","Diagnostic information readable":"No","For Redundant Control Of A Load":"Yes; only outputs of the same group","from backplane bus 5 V DC, max.":"110 mA","Between The Channels, In Groups Of":"8","For Signal \"1\" Minimum Load Current":"5 mA","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","For Signal \"0\" Residual Current, Max.":"0.5 mA","Between The Channels And Backplane Bus":"Yes; Optocoupler","Status indicator digital output (green)":"Yes; per channel","from load voltage L+ (without load), max.":"160 mA","Installation altitude above sea level, max.":"5 000 m","Limitation of inductive shutdown voltage to":"L+ (-53 V)","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","for signal \"1\" permissible range for 0 to 40 °C, max.":"0.6 A","for signal \"1\" permissible range for 0 to 40 °C, min.":"5 mA","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$708.66 – $1,933.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/16d82939ea611fbe7916b9e9e6b1cffe.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=528955&mlfb=6AG1322-1BL00-2AA0"},"ai":{"faq":[{"question":"What are the operating temperature limits?","answer":"Rated for -40 °C to 70 °C ambient."},{"question":"What certifications does this module hold?","answer":"CE, UL (File E239877), KC, EAC (formerly GOST-R), RCM (formerly C-TICK), and EN 50155 (T1, Category 1, Class A/B)."},{"question":"What is the typical short-circuit response threshold?","answer":"Typical 1 A per channel. The protection is electronic and resets after the overload clears."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1322-1BL00-2AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1322-1BL00-2AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}