{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1322-1CF00-7AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1322-1CF00-7AA0","canonicalUrl":"https://aoctrl.com/siemens/6AG1322-1CF00-7AA0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1322-1CF00-7AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens S7-300 SM 322 digital output module, 6AG1322-1CF00-7AA0, 8 channels, 48-125 VDC, 4 A per channel, -40 to 70 °C, EN 50155 railway certified.","salesMarkdown":"## Active production — extended temperature S7-300 DO The 6AG1322-1CF00-7AA0: The wide supply range (48-125 VDC) covers nominal 48 V, 60 V, 72 V, 110 V, and 125 V DC control buses common in rail, marine, and industrial sites — no separate module variant needed for each rail voltage. ## Railway temperature grade and environmental certs The UL listing (File E239877) and CE, EAC, KC, and RCM marks cover North American, European, Eurasian, Korean, and Australian regulatory acceptance. The 1500 V AC channel-to-channel isolation test confirms galvanic separation between outputs — critical when adjacent channels feed different control circuits or share a common fault path. ## Current derating and output characteristics The 4 A per-channel rating holds at 40 °C and 50 °C, then drops to 3 A at 60 °C and 1 A at 70 °C. The response threshold is 4.4 A typical — the module trips the group-error LED (SF red) when an output exceeds this level, but there is no per-channel fuse or diagnostic alarm. Spare fuses (6.3 A / 250 V, quick-response, 5x20 mm) are carried on the module for field replacement. Switching times are 2 ms max (0→1) and 15 ms max (1→0), with a maximum lamp-load frequency of 10 Hz. The minimum signal-1 voltage is L+ (-1.2 V), so the output stage saturates close to the supply rail — important for long cable runs where voltage drop is a concern. ## Physical fit and cable length limits The module occupies one S7-300 slot (40 mm wide, 125 mm high, 120 mm deep, ~250 g) and requires a 20-pin front connector (ordered separately). Unshielded cable runs up to 600 m; shielded runs up to 1000 m — the 600 m unshielded limit is the practical constraint for most plant-floor wiring without conduit. Typical power loss is 7.2 W — account for this in the enclosure thermal budget, especially when multiple modules populate the rack in a sealed cabinet.","metaTitle":"Siemens 6AG1322-1CF00-7AA0 SM 322 DO 48V-125V DC, 4A","metaDescription":"Siemens 6AG1322-1CF00-7AA0 S7-300 digital output module, 48-125 VDC, 4 A/ch, -40 to 70 °C, EN 50155, UL E239877. Active production, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Depth":"120 mm","Width":"40 mm","Height":"125 mm","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,567.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c2ef1493d8a2510fb60adf3a1d72cdfa.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=106763&mlfb=6AG1322-1CF00-7AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AG1322-1CF00-7AA0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1322-1CF00-7AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1322-1CF00-7AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}