{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1322-1HH01-2AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1322-1HH01-2AA0","canonicalUrl":"https://aoctrl.com/siemens/6AG1322-1HH01-2AA0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1322-1HH01-2AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens S7-300 digital output module, 16 relay outputs, 2 A per channel, extended temperature range -40 to 70 °C, EN 50155 railway certified, order code 6AG1322-1HH01-2AA0.","salesMarkdown":"## 16 relay outputs, 2 A per channel, -40 to 70 °C The Siemens 6AG1322-1HH01-2AA0 is a digital output module for the S7-300 platform, packing 16 relay-switched outputs rated 2 A per channel for both resistive and inductive loads at 230 V AC and 24 V DC. The 2 A rating covers the common control loads: contactors, solenoid valves, signal lamps, and small motor starters. The relay outputs provide galvanic isolation between channels, so a short on one output won't cascade into the adjacent circuit. ## Railway-grade build with EN 50155 certification This is the SIPLUS variant, meaning it carries EN 50155 certification for rolling stock and trackside equipment — sections 4, 5, and 12, covering temperature class T1, category 1, class A/B. The standard S7-300 SM 322 relay output module (6ES7322-1HH01-0AA0) lacks this certification and the extended temperature range. The -40 to 70 °C operating range is the key differentiator from the standard 0 to 60 °C industrial module. For a BOM going into a rail application or a cold-climate installation, this is the part that stays within spec without a heater or derating. ## Current production, sourced per RFQ The module requires a 20-pin front connector (sold separately). The 40 mm width fits a single S7-300 slot; the 125 mm height and 120 mm depth match the standard S7-300 envelope, so it swaps into an existing rack without re-spacing. ## Approvals and compliance for global installs CE, UL (File E239877), KC, EAC, and RCM approvals are on file — the module clears for European, North American, Korean, Eurasian, and Australian markets without additional certification work. Isolation tested at 1 500 V AC between channels and the backplane bus. The 4.5 W typical power loss stays within the S7-300 rack budget; the 1 000 m shielded cable length gives headroom for distributed I/O in a railcar or plant floor layout.","metaTitle":"Siemens 6AG1322-1HH01-2AA0 Digital Output Module, 16 Relay","metaDescription":"Siemens 6AG1322-1HH01-2AA0 digital output module with 16 relay outputs, 2 A per channel, -40 to 70 °C range, EN 50155 railway certified.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":[],"specifications":{"Depth":"120 mm","Width":"40 mm","Height":"125 mm","Product Status":"Active"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$494.03","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5d6515bf94d36c23c3a2d00afb5fa513.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=143757&mlfb=6AG1322-1HH01-2AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AG1322-1HH01-2AA0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1322-1HH01-2AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1322-1HH01-2AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}