{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1326-2BF41-2AY0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1326-2BF41-2AY0","canonicalUrl":"https://aoctrl.com/siemens/6AG1326-2BF41-2AY0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1326-2BF41-2AY0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS series, fail-safe digital output module, 6AG1326-2BF41-2AY0, 8 outputs, 2 A rated, 24 V DC, SIL 3, EN 50155 (T1), diagnostic.","salesMarkdown":"## Integrator's quick read The 6AG1326-2BF41-2AY0: Temperature range follows EN 50155 T1: -25 to +55 °C ambient during regular operation; Tmax listed as 60 °C. Current derates from 5 A at 40 °C to 4 A at 60 °C, so consider grouping and ventilation. Module measures 80 x 125 x 120 mm (W x H x D), about 465 g. Isolation tested at 500 V AC between channels and backplane bus; channels grouped in groups of four with full isolation between groups. DIN-rail mount, 40-pin front connector required — pick a compatible base unit (ET 200MP or ET 200SP depending on system). Width of 80 mm occupies a standard module slot. Switching frequencies: resistive load max 30 Hz, inductive load max 2 Hz, lamp load max 10 Hz. For pure resistive loads and good ventilation, count on 5 A per channel up to 40 °C; above that, drop to 4 A. Reverse polarity protection is not provided, so check the 24 V DC supply polarity (2L+, 3L+). Off-state leakage max 0.5 mA per channel. Power loss typ. 12 W — factor that into cabinet cooling.","metaTitle":"Siemens 6AG1326-2BF41-2AY0 SIPLUS, 8DO, 2A, SIL3 EN50155","metaDescription":"SIPLUS fail-safe digital output module, 8 outputs at 2 A rated, SIL 3, EN 50155 T1, -25 to +55 °C. CE, KC, EAC, RCM. Current lifecycle; sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Max.":"60 °C; = Tmax; the rated temperature range of -25 ... +55 °C (T1) applies for the use on railway vehicles according to EN50155","Min.":"-25 °C; = Tmin","Depth":"120 mm","Width":"80 mm","title":"6AG1326-2BF41-2AY0","Height":"125 mm","CE mark":"Yes","EN 50155":"Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B, EN 50155:2007","KC approval":"Yes","description":"***spare part*** SIPLUS S7-300 SM 326F DQ8 based on 6ES7326-2BF41-0AB0 with conformal coating, -25…+60 °C, digital output F-DQ 8x 24 V DC/2A PM fail-safe digital output sinking-sourcing up to category 4 (EN 954-1), SIL 3 (IEC 61508)","Shielded, Max.":"200 m; 200 m for SIL 3, AK 6, Cat 4","acc. to EN 954":"Cat. 4","Weight, approx.":"465 g","lifecycle_stage":"current","Diagnostic alarm":"Yes; Parameterizable","Power loss, typ.":"12 W","Rated value (DC)":"24 V; 2L+, 3L+","Unshielded, Max.":"200 m","On Lamp Load, Max.":"10 Hz","up to 40 °C, max.":"5 A","up to 60 °C, max.":"4 A","Fail-safe operation":"Yes","Between The Channels":"Yes","For Signal \"1\", Min.":"L+ (-1.0 V)","Group error SF (red)":"Yes","EAC (formerly Gost-R)":"Yes","Isolation tested with":"500V AC for 1 min (internal voltage limiting to ±120V)","RCM (formerly C-TICK)":"Yes","SIL acc. to IEC 61508":"SIL 3","Required Front Connector":"40-pin","Short-circuit protection":"Yes","Number of digital outputs":"8","With Inductive Load, Max.":"2 Hz","With Resistive Load, Max.":"30 Hz","For Signal \"1\" Rated Value":"2 A","Reverse polarity protection":"No","from supply voltage 1L+, max.":"75 mA","Diagnostic information readable":"Yes","from backplane bus 5 V DC, max.":"100 mA","Between The Channels, In Groups Of":"4","For Signal \"0\" Residual Current, Max.":"0.5 mA","Between The Channels And Backplane Bus":"Yes","Performance level according to ISO 13849-1":"e","from load voltage 2L+ (without load), max.":"100 mA","from load voltage 3L+ (without load), max.":"100 mA","Installation altitude above sea level, max.":"2 000 m","Limitation of inductive shutdown voltage to":"L+ (-33 V)","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m)","for signal \"1\" permissible range for 0 to 40 °C, max.":"2 A; with horizontal installation, 1 A with vertical installation","for signal \"1\" permissible range for 0 to 40 °C, min.":"7 mA","Between The Channels And The Power Supply Of The Electronics":"Yes"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ecd66caaabc711c7212f8d48c69f1ea8.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=249417&mlfb=6AG1326-2BF41-2AY0"},"ai":{"faq":[{"question":"What is its operating temperature range?","answer":"Rated for EN 50155 T1: -25 °C to +55 °C ambient. Tmax is 60 °C. The system temperature class T1 applies."},{"question":"What front connector is needed?","answer":"A 40-pin front connector is required. It is not included with the module."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1326-2BF41-2AY0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1326-2BF41-2AY0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}