{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1331-7KB02-2AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1331-7KB02-2AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1331-7KB02-2AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1331-7KB02-2AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS 6AG1331-7KB02-2AB0 analog input module, thermocouple and RTD plus voltage/current/resistance, parameterizable, -40 °C to 70 °C, UL/CE/KC marked.","salesMarkdown":"## What lands on the DIN rail The Siemens 6AG1331-7KB02-2AB0 is an analog input module that accepts thermocouples, the common RTD types — Pt 100 and Ni 100 — and a broad set of voltage, current and resistance ranges. One parameterizable module covers thermocouples, resistance thermometers and standard process signals, which is what makes it a sensible single-line BOM entry for a mixed sensor panel rather than a dedicated card per signal type. The module carries a CE mark, a KC approval and a UL listing under file E239877, so it is documented for North American, European and Korean panel builds. ## What it will and will not read The supported thermocouple list is B, E, J, K, N; R, S, T, L and U are not on the supported list, so a Type K or Type J probe is the safe default and a Type T low-temperature bath probe needs a different module. RTD coverage is Pt 100 and Ni 100; Cu 10 is not supported. The module is not specified against the rail vehicle or trackside EMC standards, so those environments need a different variant; the listed industrial compliance is UL/CE/KC only.","metaTitle":"Siemens 6AG1331-7KB02-2AB0 AI module, -40 to 70 °C","metaDescription":"Siemens 6AG1331-7KB02-2AB0 analog input module for SIPLUS, thermocouple + RTD + voltage/current, -40 °C to 70 °C, UL/CE/KC. RFQ for active supply.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Analog Input Modules"],"specifications":{"Max.":"70 °C","Min.":"-40 °C","Cu 10":"No","Depth":"120 mm","Width":"40 mm","title":"6AG1331-7KB02-2AB0","Height":"125 mm","Ni 100":"Yes","Pt 100":"Yes","Type E":"Yes","Type J":"Yes","Type K":"Yes","Type L":"No","Type N":"Yes","Type R":"No","Type S":"No","Type T":"No","Type U":"No","CE mark":"Yes","Current":"Yes","Voltage":"Yes","EN 50155":"No","0 to +10 V":"No","0 to 20 mA":"Yes","1 V to 5 V":"Yes","EN 50121-4":"No","Resistance":"Yes","1 V to 10 V":"No","KC approval":"Yes","UL approval":"Yes; File E239877","description":"SIPLUS S7-300 SM 331 2AI 20-pole based on 6ES7331-7KB02-0AB0 with conformal coating, -25…+70 °C, analog input isolated 2 AI, resolution 9/12/14 bits, U/I/thermocouple/resistor, alarm, diagnostics, 1x 20-pole, removing/inserting with active backplane bus","-1 V to +1 V":"Yes","-5 V to +5 V":"Yes","Thermocouple":"Yes","0 To 150 Ohms":"Yes","0 To 300 Ohms":"Yes","0 To 600 Ohms":"Yes","4 mA to 20 mA":"Yes","-10 V to +10 V":"Yes","0 To 6000 Ohms":"No","Shielded, Max.":"200 m; 50 m at 80 mV and thermocouples","Parameterizable":"Yes","Weight, approx.":"250 g","lifecycle_stage":"current","-10 mA to +10 mA":"Yes","-2.5 V to +2.5 V":"Yes","-20 mA to +20 mA":"Yes","-50 mV to +50 mV":"No","-80 mV to +80 mV":"Yes","Diagnostic alarm":"Yes","Power loss, typ.":"1.3 W","Rated value (DC)":"24 V","For Thermocouples":"Type E, J, K, L, N","Limit value alarm":"Yes; Parameterizable, channel 0","-250 mV to +250 mV":"Yes","-3.2 mA to +3.2 mA":"Yes","-500 mV to +500 mV":"Yes","Between The Channels":"No","Diagnostics function":"Yes; Parameterizable","Group error SF (red)":"Yes","EAC (formerly Gost-R)":"Yes","Isolation tested with":"500 V DC","RCM (formerly C-TICK)":"Yes","Resistance thermometer":"Yes","For Voltage Measurement":"Yes","Number of analog inputs":"2","Type TXK/TXK(L) to GOST":"No","Required Front Connector":"20-pin","Input resistance (Ni 100)":"10 MΩ; Standard","Input resistance (Pt 100)":"10 kΩ; Standard","Input resistance (Type E)":"10 MΩ","Input resistance (Type K)":"10 MΩ","Input resistance (Type N)":"10 MΩ","Input resistance (type J)":"10 MΩ","For Resistance Thermometer":"Pt100 (standard, climatic range), Ni100 (standard, climatic range)","For resistance measurement":"1","Reverse polarity protection":"Yes","Input resistance (0 to 20 mA)":"25 Ω","Input resistance (1 V to 5 V)":"100 kΩ","Diagnostic information readable":"Yes","Input resistance (-1 V to +1 V)":"10 MΩ","Input resistance (-5 V to +5 V)":"100 kΩ","from backplane bus 5 V DC, max.":"50 mA","Input resistance (0 to 150 ohms)":"10 MΩ","Input resistance (0 to 300 ohms)":"10 MΩ","Input resistance (0 to 600 ohms)":"10 MΩ","Input resistance (4 mA to 20 mA)":"25 Ω","Input resistance (-10 V to +10 V)":"100 kΩ","Integration time, parameterizable":"Yes; 2,5 / 16,67 / 20 / 100 ms","Internal Temperature Compensation":"Yes","Input resistance (-10 mA to +10 mA)":"25 Ω","Input resistance (-2.5 V to +2.5 V)":"100 kΩ","Input resistance (-20 mA to +20 mA)":"25 Ω","Input resistance (-80 mV to +80 mV)":"10 MΩ","Input resistance (-250 mV to +250 mV)":"10 MΩ","Input resistance (-3.2 mA to +3.2 mA)":"25 Ω","Input resistance (-500 mV to +500 mV)":"10 MΩ","Between The Channels And Backplane Bus":"Yes","Current, relative to input range, (+/-)":"0.5 %; 3.2 to 20 mA","Voltage, relative to input range, (+/-)":"0.6 %; ±0.6% (80 mV, 2.5 V to 10 V); ±0.4% (250 mV to 1 000 mV)","from load voltage L+ (without load), max.":"80 mA","For Definable Comparison Point Temperature":"Yes","Resistance, relative to input range, (+/-)":"0.5 %; 150, 300, 600 Ohm","Installation altitude above sea level, max.":"5 000 m","For Current Measurement As 2-Wire Transducer":"Yes","For Current Measurement As 4-Wire Transducer":"Yes","Thermocouple, relative to input range, (+/-)":"0.7 %; Type E, N, J, K, L","For Resistance Measurement With Two-Wire Connection":"Yes","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","For Resistance Measurement With Four-Wire Connection":"Yes","Resolution with overrange (bit including sign), max.":"15 bit; Unipolar: 9/12/12/14 bit; bipolar: 9 bit + sign/12 bit + sign/12 bit + sign/14 bit + sign","For Resistance Measurement With Three-Wire Connection":"Yes","Resistance thermometer, relative to input range, (+/-)":"0.6 %; ±0.5% (Pt100/ Ni100), ±0.6% (Pt100 climate)","External Temperature Compensation With Compensations Socket":"Yes","Between The Channels And The Power Supply Of The Electronics":"Yes; Not for 2-wire transmitters","Constant measurement current for resistance-type transmitter, typ.":"1.67 mA","Interference voltage suppression for interference frequency f1 in Hz":"400 / 60 / 50 / 10 Hz","Permissible Input Current For Current Input (Destruction Limit), Max.":"40 mA","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20)","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$300.99 – $893.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5a105f90ac110c8b64c395c0a930cc6a.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=469211&mlfb=6AG1331-7KB02-2AB0"},"ai":{"faq":[{"question":"What is 6AG1331-7KB02-2AB0's listed max. (70 °C) on this component line?","answer":"Maximum operating ambient is 70 °C for the 6AG1331-7KB02-2AB0."},{"question":"What is 6AG1331-7KB02-2AB0's listed min. (-40 °C) on this component line?","answer":"Minimum operating ambient is -40 °C for the 6AG1331-7KB02-2AB0."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1331-7KB02-2AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1331-7KB02-2AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}