{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1331-7KF02-2AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1331-7KF02-2AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1331-7KF02-2AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1331-7KF02-2AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 6AG1331-7KF02-2AB0 analog input module, EN 50155 rail-certified, -40 to 70°C, Pt100/Ni100/TC J/K/E/N/0-20mA/±5V, 40x125x120 mm.","salesMarkdown":"## Rail-certified analog input for harsh environments The 6AG1331-7KF02-2AB0: This means the module is qualified for rolling stock and wayside installations where the electronics must survive thermal cycling, vibration, and supply transients defined by the rail standard. ## Supported input types and signal ranges The module accepts Pt 100 and Ni 100 RTDs in standard curve, plus thermocouple types J, K, E, and N. For voltage signals it handles -1 V to +1 V, -5 V to +5 V, and 1 V to 5 V ranges; current inputs cover 0 to 20 mA. Resistance and direct voltage/current measurement modes are also available, giving flexibility for a range of transmitters and sensors. The module carries CE mark, UL approval under File E239877, and KC approval, covering European, North American, and South Korean regulatory markets. The EN 50155 certification is the key differentiator — it confirms the module meets the railway application standard for temperature, shock, vibration, and power supply variations.","metaTitle":"Siemens 6AG1331-7KF02-2AB0 Analog Input Module, -40 to 70°C","metaDescription":"Siemens 6AG1331-7KF02-2AB0 analog input module. Rated -40 to 70°C, EN 50155 certified for rail. Supports Pt100, Ni100, TC types J/K/E/N, 0-20mA, ±5V.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Analog Input Modules"],"specifications":{"Max.":"70 °C","Min.":"-40 °C","Cu 10":"No","Depth":"120 mm","Width":"40 mm","title":"6AG1331-7KF02-2AB0","Height":"125 mm","Ni 100":"Yes; Standard","Ni 120":"No","Ni 200":"No","Ni 500":"No","Pt 100":"Yes; Standard","Pt 200":"No","Pt 500":"No","Type B":"No","Type C":"No","Type E":"Yes","Type J":"Yes","Type K":"Yes","Type L":"No","Type N":"Yes","Type R":"No","Type S":"No","Type T":"No","Type U":"No","CE mark":"Yes","Current":"Yes","Ni 1000":"No","Pt 1000":"No","Voltage":"Yes","EN 50155":"Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B, EN 50155:2007 (see SIOS entry 109755985)","0 to +10 V":"No","0 to 20 mA":"Yes","1 V to 5 V":"Yes","LG-Ni 1000":"No","Resistance":"Yes","1 V to 10 V":"No","KC approval":"Yes","UL approval":"Yes; File E239877","description":"SIPLUS S7-300 SM 331 20-pole based on 6ES7331-7KF02-0AB0 with conformal coating, -25…+70 °C, analog input isolated 8 AI, resolution 9/12/14 bits, U/I/thermocouple/resistor, alarm, diagnostics, 1x 20-pole removing/inserting with active backplane bus","-1 V to +1 V":"Yes","-5 V to +5 V":"Yes","Thermocouple":"Yes","0 To 150 Ohms":"Yes","0 To 300 Ohms":"Yes","0 To 600 Ohms":"Yes","4 mA to 20 mA":"Yes","-10 V to +10 V":"Yes","0 To 6000 Ohms":"No","Shielded, Max.":"200 m; 50 m at 80 mV and thermocouples","Parameterizable":"Yes","Weight, approx.":"250 g","lifecycle_stage":"current","-10 mA to +10 mA":"Yes","-2.5 V to +2.5 V":"Yes","-20 mA to +20 mA":"Yes","-50 mV to +50 mV":"No","-80 mV to +80 mV":"Yes","Diagnostic alarm":"Yes; Parameterizable, channels 0 and 2","Power loss, typ.":"1 W","Rated value (DC)":"24 V; A power supply according to EN 50155 shall be used for railway applications","For Thermocouples":"Type E, J, K, L, N","Limit value alarm":"Yes; Parameterizable","-250 mV to +250 mV":"Yes","-3.2 mA to +3.2 mA":"Yes","-500 mV to +500 mV":"Yes","Between The Channels":"No","Diagnostics function":"Yes; Parameterizable","Group error SF (red)":"Yes","EAC (formerly Gost-R)":"Yes","Isolation tested with":"500 V DC","RCM (formerly C-TICK)":"Yes","Resistance thermometer":"Yes","For Voltage Measurement":"Yes","Number of analog inputs":"8","Type TXK/TXK(L) to GOST":"No","Required Front Connector":"20-pin","Input resistance (Ni 100)":"10 MΩ","Input resistance (Pt 100)":"10 MΩ","Input resistance (Type E)":"10 MΩ","Input resistance (Type K)":"10 MΩ","Input resistance (Type N)":"10 MΩ","Input resistance (type J)":"10 MΩ","For Resistance Thermometer":"Pt100 (standard, climatic range), Ni100 (standard, climatic range)","For resistance measurement":"4","Reverse polarity protection":"Yes","Input resistance (0 to 20 mA)":"25 Ω","Input resistance (1 V to 5 V)":"100 kΩ","Diagnostic information readable":"Yes","Input resistance (-1 V to +1 V)":"10 MΩ","Input resistance (-5 V to +5 V)":"100 kΩ","from backplane bus 5 V DC, max.":"50 mA","Input resistance (0 to 150 ohms)":"10 MΩ","Input resistance (0 to 300 ohms)":"10 MΩ","Input resistance (0 to 600 ohms)":"10 MΩ","Input resistance (4 mA to 20 mA)":"25 Ω","Input resistance (-10 V to +10 V)":"100 kΩ","Integration time, parameterizable":"Yes; 2,5 / 16,67 / 20 / 100 ms","Internal Temperature Compensation":"Yes","Input resistance (-10 mA to +10 mA)":"25 Ω","Input resistance (-2.5 V to +2.5 V)":"100 kΩ","Input resistance (-20 mA to +20 mA)":"25 Ω","Input resistance (-80 mV to +80 mV)":"10 MΩ","Input resistance (-250 mV to +250 mV)":"10 MΩ","Input resistance (-3.2 mA to +3.2 mA)":"25 Ω","Input resistance (-500 mV to +500 mV)":"10 MΩ","Between The Channels And Backplane Bus":"Yes","Current, relative to input range, (+/-)":"0.5 %; 3.2 to 20 mA","Voltage, relative to input range, (+/-)":"0.6 %; ±0.4 % (250 mV to 1 000 mV); ±0.6 % (2.5 mV to 10 mV); ±0.7 % (80 mV)","from load voltage L+ (without load), max.":"200 mA","For Definable Comparison Point Temperature":"Yes","Resistance, relative to input range, (+/-)":"0.5 %; 150, 300, 600 Ohm","Installation altitude above sea level, max.":"5 000 m","For Current Measurement As 2-Wire Transducer":"Yes","For Current Measurement As 4-Wire Transducer":"Yes","Thermocouple, relative to input range, (+/-)":"0.7 %; Type E, N, J, K, L","For Resistance Measurement With Two-Wire Connection":"Yes","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","For Resistance Measurement With Four-Wire Connection":"Yes","Resolution with overrange (bit including sign), max.":"15 bit; Unipolar: 9/12/12/14 bit; bipolar: 9 bit + sign/12 bit + sign/12 bit + sign/14 bit + sign","For Resistance Measurement With Three-Wire Connection":"Yes","Resistance thermometer, relative to input range, (+/-)":"0.6 %; ±0.5% (Pt100/ Ni100), ±0.6% (Pt100 climate)","External Temperature Compensation With Compensations Socket":"Yes","Between The Channels And The Power Supply Of The Electronics":"Yes","Constant measurement current for resistance-type transmitter, typ.":"1.67 mA","Interference voltage suppression for interference frequency f1 in Hz":"400 / 60 / 50 / 10 Hz","Permissible Input Current For Current Input (Destruction Limit), Max.":"40 mA","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20)","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$2,463.00","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/902b73fe279887776f0f64034e81e85c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=446273&mlfb=6AG1331-7KF02-2AB0"},"ai":{"faq":[{"question":"Can 6AG1331-7KF02-2AB0 replace 6ES7331-7KF02-0AB0 directly?","answer":"The 6AG1331-7KF02-2AB0 is the SIPLUS extreme variant of the standard 6ES7331-7KF02-0AB0, with identical functionality but extended temperature range and EN 50155 rail certification. It is a drop-in replacement for applications requiring wider environmental tolerance."},{"question":"How can I order the Siemens 6AG1331-7KF02-2AB0 analog input module?","answer":"This module is sourced to order against your BOM quantity."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1331-7KF02-2AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1331-7KF02-2AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}