{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1332-5HB01-2AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1332-5HB01-2AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1332-5HB01-2AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1332-5HB01-2AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS, analog output module, 6AG1332-5HB01-2AB0, 2 channels, -40 to 70 °C, EN 50155.","salesMarkdown":"The 6AG1332-5HB01-2AB0: Two output channels share a common conversion time of 0.8 ms per channel. The module accepts voltage (0–10 V, 1–5 V, ±10 V) and current (0–20 mA, 4–20 mA, ±20 mA) outputs, covering nearly any loop or actuator interface on a 24 V DC control bus. On the current outputs the load can go up to 500 Ω; voltage outputs need a minimum 1 kΩ load. Diagnostics are fully parameterizable — the module can raise a group error (red SF LED) and read back fault details over the backplane. Isolation between channels and the bus is tested at 500 V DC, and reverse polarity on the supply is blocked onboard. For inductive loads, the settling time stretches to 0.5 ms (1 mH) or 3.3 ms (10 mH); resistive and capacitive loads settle in 0.2 ms and 3.3 ms respectively. Beyond EN 50155, the module carries UL (File E239877), CE, KC, EAC, and RCM marks. The 24 V DC supply must come from a source that meets EN 50155 for railway installations, but the module itself is rated for general industrial approvals as well. This module is in current lifecycle stage. The 20-pin front connector is required but sold separately.","metaTitle":"Siemens 6AG1332-5HB01-2AB0 SIPLUS AO Module, -40..70°C","metaDescription":"Current-production SIPLUS analog output module with 2 channels, -40 to 70°C, EN 50155 railway certification. Sourced to order against BOM line.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Analog Output Modules"],"specifications":{"Max.":"70 °C","Min.":"-40 °C","Depth":"120 mm","Width":"40 mm","title":"6AG1332-5HB01-2AB0","Height":"125 mm","CE mark":"Yes","EN 50155":"Yes; Sections 4, 5 and 12; no further agreements apply; T1, Category 1, Class A/B, EN 50155:2007 (see SIOS entry 109755985)","0 to 10 V":"Yes","0 to 20 mA":"Yes","1 V to 5 V":"Yes","KC approval":"Yes","UL approval":"Yes; File E239877","description":"SIPLUS S7-300 SM 332 2AQ 20-pole based on 6ES7332-5HB01-0AB0 with conformal coating, -25…+70 °C, analog output isolated, 2 AQ, U/I; resolution 11/12 bit 20-pole, removing/inserting with active backplane bus possible","4 mA to 20 mA":"Yes","-10 V to +10 V":"Yes","Shielded, Max.":"200 m","Weight, approx.":"220 g","lifecycle_stage":"current","-20 mA to +20 mA":"Yes","Diagnostic alarm":"Yes; Parameterizable","Power loss, typ.":"3 W","Rated value (DC)":"24 V; A power supply according to EN 50155 shall be used for railway applications","For Inductive Load":"0.5 ms; 0.5 ms (1 mH); 3.3 ms (10 mH)","For Resistive Load":"0.2 ms","For Capacitive Load":"3.3 ms","Between The Channels":"No","Diagnostics function":"Yes; Parameterizable","Group error SF (red)":"Yes","EAC (formerly Gost-R)":"Yes","Isolation tested with":"500 V DC","RCM (formerly C-TICK)":"Yes","Number of analog outputs":"2","Required Front Connector":"20-pin","With Current Outputs, Max.":"500 Ω","With Voltage Outputs, Min.":"1 kΩ","Reverse polarity protection":"Yes","Conversion time (per channel)":"0.8 ms","Diagnostic information readable":"Yes","from backplane bus 5 V DC, max.":"60 mA","Current output, no-load voltage, max.":"18 V","Between The Channels And Backplane Bus":"Yes","Between the channels and load voltage L+":"Yes","Current, relative to output range, (+/-)":"0.5 %","Voltage output, short-circuit protection":"Yes","Voltage, relative to output range, (+/-)":"0.4 %","from load voltage L+ (without load), max.":"135 mA","With Current Outputs, Inductive Load, Max.":"10 mH","Installation altitude above sea level, max.":"5 000 m","Voltage output, short-circuit current, max.":"25 mA","With Voltage Outputs, Capacitive Load, Max.":"1 µF","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Resolution with overrange (bit including sign), max.":"12 bit; ±10 V, ±20 mA, 4 mA to 20 mA, 1 V to 5 V: 11 bit + sign; 0 V to 10 V, 0 mA to 20 mA: 12 bit","Between The Channels And The Power Supply Of The Electronics":"Yes","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$513.08","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/086ff8703ad2d690e4ae01e9ab31f617.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=49990&mlfb=6AG1332-5HB01-2AB0"},"ai":{"faq":[{"question":"What temperature range does the module support?","answer":"It is rated for -40 °C to 70 °C operating range, making it suitable for railway and cold-climate installations."},{"question":"What compliance certifications does it carry?","answer":"The module holds EN 50155 (railway), UL (File E239877), CE, KC, EAC, and RCM approvals."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1332-5HB01-2AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1332-5HB01-2AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}