{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1332-5HF00-2AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1332-5HF00-2AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1332-5HF00-2AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1332-5HF00-2AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS analog output module, 6AG1332-5HF00-2AB0, 8 channels (4 at 70°C), 0-10 V, 4-20 mA, -40 to 70 °C, 40 mm.","salesMarkdown":"## Analog output module for ET 200MP — commissioning notes The 6AG1332-5HF00-2AB0: Conversion time sits at 0.8 ms per channel, which keeps the update rate fast enough for most process loops. The module requires a 40-pin front connector and draws up to 100 mA from the backplane 5 V rail plus 6 W typ from the 24 V supply. Diagnostic functions are parameterizable and include a group error SF LED and readable diagnostics. ## Mounting and environmental envelope Width is 40 mm, depth 120 mm, height 125 mm — fits a standard 40 mm slot in an ET 200MP rack. Reverse polarity protection on the 24 V input reduces risk during commissioning. UL listed (File E239877), CE, KC, EAC, RCM approvals cover most global installs.","metaTitle":"Siemens 6AG1332-5HF00-2AB0 SIPLUS Analog Output, 8 Ch, -40-7","metaDescription":"Siemens SIPLUS analog output module 6AG1332-5HF00-2AB0, 8 channels (4 at 70°C), 0-10V/4-20mA, -40 to 70°C, 40mm wide, UL/CE/KC/EAC/RCM. Current production, order to RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Analog Output Modules"],"specifications":{"Max.":"70 °C","Min.":"-40 °C","Depth":"120 mm","Width":"40 mm","title":"6AG1332-5HF00-2AB0","Height":"125 mm","CE mark":"Yes","EN 50155":"No","0 to 10 V":"Yes","0 to 20 mA":"Yes","1 V to 5 V":"Yes","EN 50121-4":"No","KC approval":"Yes","UL approval":"Yes; File E239877","description":"SIPLUS S7-300 SM 332 40-pole based on 6ES7332-5HF00-0AB0 with conformal coating, -25…+70 °C, analog output isolated, 8 AQ, U/I; diagnostics; resolution 11/12 bits, 40-pole, removing and inserting possible with active backplane bus","4 mA to 20 mA":"Yes","-10 V to +10 V":"Yes","Shielded, Max.":"200 m","Weight, approx.":"272 g","lifecycle_stage":"current","-20 mA to +20 mA":"Yes","Diagnostic alarm":"Yes; Parameterizable","Power loss, typ.":"6 W","Rated value (DC)":"24 V","For Inductive Load":"0.5 ms; 0.5 ms (1 mH); 3.3 ms (10 mH)","For Resistive Load":"0.2 ms","For Capacitive Load":"3.3 ms","Between The Channels":"No","Diagnostics function":"Yes; Parameterizable","Group error SF (red)":"Yes","EAC (formerly Gost-R)":"Yes","Isolation tested with":"500 V DC","RCM (formerly C-TICK)":"Yes","Number of analog outputs":"8; 4 @ +70 °C","Required Front Connector":"40-pin","With Current Outputs, Max.":"500 Ω","With Voltage Outputs, Min.":"1 kΩ","Reverse polarity protection":"Yes","Conversion time (per channel)":"0.8 ms","Diagnostic information readable":"Yes","from backplane bus 5 V DC, max.":"100 mA","Current output, no-load voltage, max.":"18 V","Between The Channels And Backplane Bus":"Yes","Between the channels and load voltage L+":"Yes","Current, relative to output range, (+/-)":"0.5 %","Voltage output, short-circuit protection":"Yes","Voltage, relative to output range, (+/-)":"0.4 %","from load voltage L+ (without load), max.":"340 mA","With Current Outputs, Inductive Load, Max.":"10 mH","Installation altitude above sea level, max.":"5 000 m","Voltage output, short-circuit current, max.":"25 mA","With Voltage Outputs, Capacitive Load, Max.":"1 µF","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Resolution with overrange (bit including sign), max.":"12 bit; ±10 V, ±20 mA, 4 mA to 20 mA, 1 V to 5 V: 11 bit + sign; 0 V to 10 V, 0 mA to 20 mA: 12 bit","Between The Channels And The Power Supply Of The Electronics":"Yes","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,424.94","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/7d9b3ee5f3279941d94cd6aa8881dfd7.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=320710&mlfb=6AG1332-5HF00-2AB0"},"ai":{"faq":[{"question":"What is the maximum operating temperature for this module?","answer":"The maximum ambient temperature is 70 °C, with the analog output count derated from 8 to 4 channels at that temperature."},{"question":"What is the minimum operating temperature?","answer":"The minimum ambient temperature is -40 °C."},{"question":"What compliance approvals does the 6AG1332-5HF00-2AB0 carry?","answer":"The module carries UL (File E239877), CE, KC, EAC, and RCM approvals."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1332-5HF00-2AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1332-5HF00-2AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}