{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1332-5HF00-4AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1332-5HF00-4AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1332-5HF00-4AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1332-5HF00-4AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens S7-300 analog output module, 8 channels, 24 V DC, bipolar voltage and current ranges, 40-pin front connector, active production.","salesMarkdown":"## Panel fit and channel count The 6AG1332-5HF00-4AB0 is an 8-channel analog output module for the S7-300 family, drawing 40 mm of DIN-rail width and 125 mm height — sits in a standard S7-300 rack slot. It needs a 40-pin front connector (not included) and pulls 100 mA from the 5 V backplane bus plus 6 W typical from the 24 V DC field supply. ## What the output ranges mean for the loop Each channel covers the common industrial signal standards: voltage outputs from -10 V to +10 V, 0 to 10 V, and 1 V to 5 V; current outputs from 0 to 20 mA, 4 to 20 mA, and -20 mA to +20 mA. That bipolar current range is unusual on an S7-300 AO — it lets you drive ±20 mA into a valve or transducer without a separate signal conditioner. Minimum load for voltage outputs is 1 kΩ; maximum burden for current outputs is 500 Ω. Conversion time per channel is 0.8 ms — fast enough for closed-loop control on a hydraulic or pneumatic valve bank. Shielded cable run is rated up to 200 m before signal degradation becomes an issue. ## What it replaces and what it doesn't The 6AG1332-5HF00-4AB0 is the SIPLUS variant of the standard 6ES7332-5HF00-0AB0. The SIPLUS version adds a conformal coating rated for medial exposure — meaning it handles condensation, corrosive gases, and dust better than the standard module. Pin-compatible in the same S7-300 slot; the 40-pin front connector and wiring are identical. If your environment is clean and dry, the standard 6ES7 variant saves cost; if the panel sees humidity or aggressive atmospheres, the SIPLUS coating is the difference between a module that lasts and one that fails mid-shift. ## Diagnostics and commissioning Parameterizable diagnostics include group error (SF red LED) and per-channel diagnostic alarm — readable over the backplane bus. Reverse polarity protection on the 24 V DC supply prevents a swapped wire from killing the module. Isolation tested at 500 V DC between the bus and field circuits.","metaTitle":"Siemens 6AG1332-5HF00-4AB0 Analog Output Module, 8 Channels","metaDescription":"Siemens 6AG1332-5HF00-4AB0 analog output module with 8 channels, 24 V DC supply, bipolar voltage and current ranges.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["Analog Output Modules"],"specifications":{"Max.":"60 °C; = Tmax","Min.":"0 °C; = Tmin","Depth":"120 mm","Width":"40 mm","Height":"125 mm","CE mark":"Yes","EN 50155":"No","0 to 10 V":"Yes","0 to 20 mA":"Yes","1 V to 5 V":"Yes","EN 50121-4":"No","FM approval":"Yes","KC approval":"Yes","UL approval":"Yes; File E239877","4 mA to 20 mA":"Yes","-10 V to +10 V":"Yes","Shielded, Max.":"200 m","Weight, approx.":"272 g","lifecycle_stage":"current","-20 mA to +20 mA":"Yes","Diagnostic alarm":"Yes; Parameterizable","Power loss, typ.":"6 W","Rated value (DC)":"24 V","For Inductive Load":"0.5 ms; 0.5 ms (1 mH); 3.3 ms (10 mH)","For Resistive Load":"0.2 ms","For Capacitive Load":"3.3 ms","Between The Channels":"No","Diagnostics function":"Yes; Parameterizable","Group error SF (red)":"Yes","EAC (formerly Gost-R)":"Yes","Isolation tested with":"500 V DC","RCM (formerly C-TICK)":"Yes","Number of analog outputs":"8","Required Front Connector":"40-pin","With Current Outputs, Max.":"500 Ω","With Voltage Outputs, Min.":"1 kΩ","Reverse polarity protection":"Yes","Conversion time (per channel)":"0.8 ms","Diagnostic information readable":"Yes","from backplane bus 5 V DC, max.":"100 mA","Current output, no-load voltage, max.":"18 V","Between The Channels And Backplane Bus":"Yes","Between the channels and load voltage L+":"Yes","Current, relative to output range, (+/-)":"0.5 %","Voltage output, short-circuit protection":"Yes","Voltage, relative to output range, (+/-)":"0.4 %","from load voltage L+ (without load), max.":"340 mA","With Current Outputs, Inductive Load, Max.":"10 mH","Voltage output, short-circuit current, max.":"25 mA","With Voltage Outputs, Capacitive Load, Max.":"1 µF","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Resolution with overrange (bit including sign), max.":"12 bit; ±10 V, ±20 mA, 4 mA to 20 mA, 1 V to 5 V: 11 bit + sign; 0 V to 10 V, 0 mA to 20 mA: 12 bit","Between The Channels And The Power Supply Of The Electronics":"Yes"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$1,047.75","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=331691&mlfb=6AG1332-5HF00-4AB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AG1332-5HF00-4AB0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1332-5HF00-4AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1332-5HF00-4AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}