{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1334-0KE00-7AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1334-0KE00-7AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1334-0KE00-7AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1334-0KE00-7AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC S7-300 SM 334, 4 analog inputs (Pt100, 0-10V, 0-10000 Ω), 2 analog outputs (0-10V), 24 V DC, 40 mm wide, -40 to 70 °C, UL E239877.","salesMarkdown":"## Analog I/O for the S7-300 rack The Siemens 6AG1334-0KE00-7AB0 is a mixed analog I/O module for the SIMATIC S7-300 system, carrying 4 inputs and 2 outputs in a single slot. The inputs accept Pt100 resistance thermometers (climatic-range-only), 0–10 V voltage, and resistive loads up to 10 kΩ; the outputs are 0–10 V, rated for a minimum load of 2.5 kΩ. All channels are isolated from the backplane bus with a 500 V DC test. Power draw is a typical 2 W from the 24 V DC backplane supply.","metaTitle":"Siemens 6AG1334-0KE00-7AB0 Analog I/O Module, 4AI/2AO, -40..","metaDescription":"Active S7-300 analog I/O module with 4 inputs, 2 outputs, Pt100 support, 24 VDC, -40 to 70 °C, UL E239877. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLC I/O & Expansion Modules"],"specifications":{"Max.":"70 °C","Min.":"-40 °C","Depth":"117 mm","Width":"40 mm","title":"6AG1334-0KE00-7AB0","Alarms":"No","Height":"125 mm","Pt 100":"Yes; only climatic range","CE mark":"Yes","Current":"No","Voltage":"Yes","0 to 10 V":"Yes","0 to +10 V":"Yes","Resistance":"Yes","KC approval":"Yes","UL approval":"Yes; File E239877","description":"SIPLUS S7-300 SM 334 4AI 2AQ based on 6ES7334-0KE00-0AB0 with conformal coating, -25…+70 °C, analog module isolated, 4 AI/2 AQ, 12 bit, 0-10 V for Pt100 (climatic range -120-155 degrees) and 10 kOhm measuring range, 1x 20-pole","Thermocouple":"No","Shielded, Max.":"100 m","0 To 10000 Ohms":"Yes","Parameterizable":"Yes","Weight, approx.":"200 g","lifecycle_stage":"current","Power loss, typ.":"2 W","Rated value (DC)":"24 V","For Resistive Load":"0.8 ms","For Capacitive Load":"0.8 ms","Between The Channels":"No","Diagnostics function":"No","EAC (formerly Gost-R)":"Yes","Integration time (ms)":"16,67 / 20 ms","Isolation tested with":"500 V DC","RCM (formerly C-TICK)":"Yes","Resistance thermometer":"Yes","For Voltage Measurement":"Yes","For voltage measurement":"2","Number of analog inputs":"4","Number of analog outputs":"2","Required Front Connector":"20-pin","For Resistance Thermometer":"Pt100 (climate)","For resistance measurement":"4","With Voltage Outputs, Min.":"2.5 kΩ","Reverse polarity protection":"Yes","Input resistance (0 to 10 V)":"100 kΩ","Conversion time (per channel)":"500 µs","Cycle time (all channels) max.":"85 ms","from backplane bus 5 V DC, max.":"60 mA","Integration time, parameterizable":"Yes","Between The Channels And Backplane Bus":"Yes","Voltage, relative to input range, (+/-)":"0.5 %; 0 to 10V","Voltage output, short-circuit protection":"Yes","Voltage, relative to output range, (+/-)":"0.85 %","Resistance, relative to input range, (+/-)":"2.8 %; 10 kOhm","Installation altitude above sea level, max.":"5 000 m","Voltage output, short-circuit current, max.":"10 mA","With Voltage Outputs, Capacitive Load, Max.":"1 µF","For Resistance Measurement With Two-Wire Connection":"Yes","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","For Resistance Measurement With Four-Wire Connection":"Yes","Resolution with overrange (bit including sign), max.":"12 bit","from supply and load voltage L+ (without load), max.":"80 mA","For Resistance Measurement With Three-Wire Connection":"Yes","Resistance thermometer, relative to input range, (+/-)":"0.8 %","Between The Channels And The Power Supply Of The Electronics":"Yes","Constant measurement current for resistance-type transmitter, typ.":"490 µA; at PT100 (490 µA), at 10 kOhm (105 µa)","Interference voltage suppression for interference frequency f1 in Hz":"50 / 60 Hz","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20)","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$684.53","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/ad22ad495586e17c3f20bfe5be94cf5a.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=441015&mlfb=6AG1334-0KE00-7AB0"},"ai":{"faq":[{"question":"What are its key operating temperature limits?","answer":"Rated from -40 °C to 70 °C ambient, covering both extreme cold and hot environments."},{"question":"What compliance documentation does it have?","answer":"UL approved (File E239877), plus CE, KC, EAC, and RCM marks. The front connector must be ordered separately."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1334-0KE00-7AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1334-0KE00-7AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}