{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1410-5HX08-7AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1410-5HX08-7AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1410-5HX08-7AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1410-5HX08-7AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS PCS 7 CPU 410-5H, order code 6AG1410-5HX08-7AB0, extended temperature range -40 to +70 °C, CE marked, multi-processor system at 450 MHz.","salesMarkdown":"## Extended temperature CPU for harsh environments The Siemens 6AG1410-5HX08-7AB0 is a SIPLUS variant of the PCS 7 CPU 410-5H, designed for environments where standard CPUs cannot operate. This CPU supports CFC, FBD, LAD, SCL, STL, and GRAPH programming languages. ## Communication and I/O capacity Integrated PROFINET interface provides UDP and TCP/IP communication, with loadable function blocks for custom protocol handling. PROFIBUS DPV1 is also supported. The CPU can address up to 8,192 digital inputs and 8,192 digital outputs, with 16 counters and a 64 kbyte preset work memory. MODBUS RTU/TCP is available via an add-on, extending connectivity to third-party devices and legacy equipment. This part carries the CE mark, confirming compliance with applicable EU directives for industrial control equipment.","metaTitle":"Siemens 6AG1410-5HX08-7AB0 SIPLUS PCS 7 CPU 410-5H","metaDescription":"Siemens 6AG1410-5HX08-7AB0 SIPLUS PCS 7 CPU 410-5H. Extended temp range -40 to 70 °C. CE marked. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Industrial PCs"],"specifications":{"CFC":"Yes","FBD":"Yes","LAD":"Yes","SCL":"Yes","STL":"Yes","UDP":"Yes; via integrated PROFINET interface and loadable FBs","DPV1":"Yes","Max.":"70 °C","Min.":"-40 °C","Type":"SFB","Depth":"219 mm","GRAPH":"Yes","RDREC":"8","WRREC":"8","Width":"50 mm","title":"6AG1410-5HX08-7AB0","Height":"290 mm","Inputs":"8 192; max.","MODBUS":"Yes; Via add-on","Number":"16","Preset":"64 kbyte","RD_REC":"8","TCP/IP":"Yes; via integrated PROFINET interface and loadable FBs","WR_REC":"8","via CP":"0","CE mark":"Yes","Outputs":"8 192; max.","Overall":"120","Present":"Yes","RDSYSST":"8","Routing":"Yes","WR_PARM":"8","DPNRM_DG":"8","DP_TOPOL":"1","Isolated":"Yes","PARM_MOD":"1","PROFIBUS":"Yes","WR_DPARM":"2","As Client":"Yes","As Server":"Yes","CPU speed":"450 MHz; Multi-processor system","HiGraph®":"Yes","PROFIsafe":"Yes","Retentive":"Yes","Supported":"Yes; Via CP and loadable FB","Variables":"Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters","Adjustable":"Yes","Expandable":"No","Integrated":"2","Resolution":"1 ms","S7 routing":"Yes","Size, max.":"16 384 byte","Web server":"No","Command set":"see instruction list","Granularity":"1 h","Lower Limit":"10 ms","SYNC/FREEZE":"No","Send cycles":"250 µs, 500 µs, 1 ms, 2 ms, 4 ms","Single step":"Yes","Slots, max.":"244","Upper Limit":"9 990 s","description":"SIPLUS PCS 7 CPU 410-5H based on 6ES7410-5HX08-0AB0 with conformal coating, -25…+70 °C, central processing unit for S7-400 and S7-400H/F/FH, 5 interfaces: 1x PN, 1x DP, 2x for Sync modules and 1x service. only for spare parts supply; without System Expansion Card","AS-Interface":"Yes; Via add-on","Autocrossing":"Yes","Equidistance":"No","Inputs, max.":"8 kbyte; up to 3 800 IOs (channels)","Number, max.":"see instruction list","PROFINET CBA":"No","Preset, Max.":"10 000","Status block":"Yes","With Battery":"Yes; all data","in AS, slave":"Yes","to DP, slave":"Yes","Outputs, max.":"8 kbyte; up to 3 800 IOs (channels)","Shared device":"No; however, usable as part of S7","Updating time":"250 µs to 512 ms, minimum value depends on the number of configured user data and the configured single or redundant mode","in AS, master":"Yes","to DP, master":"Yes","Alarm 8-blocks":"Yes","Ethernet, max.":"10 ms","Interface type":"Pluggable synchronization submodule (FO)","Multicomputing":"No","Nesting levels":"7","Per Slot, Max.":"128 byte","Program alarms":"Yes","Required Slots":"2","SCAN procedure":"No","Type of memory":"RAM","expandable RAM":"No","Autonegotiation":"Yes","Can Be Read Out":"Yes","Inputs, default":"16 kbyte","Number of ports":"2","Range of values":"SFCs 2, 3 and 4: 0 to 32767 hours SFC 101: 0 to 2^31 - 1 hours","Weight, approx.":"1.1 kg","Without Battery":"No","connectable OPs":"119","lifecycle_stage":"current","Adjustable, Max.":"64 kbyte","Block encryption":"Yes; With S7 block Privacy","Firmware version":"V8.1","Isochronous mode":"No","Media redundancy":"Yes","Of Which Central":"8 192; max.","Outputs, default":"16 kbyte","Power loss, typ.":"10 W","S7 communication":"Yes","Backup time, max.":"Dealt with in the module data manual with the secondary conditions and the factors of influence","Data length, max.":"1 472 byte","Integrated Switch":"Yes","PROFIBUS DP slave":"No","expandable FEPROM":"No","Inputs, adjustable":"16 kbyte","PROFIBUS DP master":"Yes","PROFINET IO Device":"No","Per Priority Class":"24","Data record routing":"Yes","Foundation Fieldbus":"Yes; via DP/FF Link","Number/Number range":"0 to 15","Outputs, adjustable":"16 kbyte","PG/OP communication":"Yes","Prioritized startup":"No","Process tasks, max.":"9; Individually adjustable from 10 ms to 5 s","Programming package":"SIMATIC PCS 7 V8.1 or higher","on Ethernet via NTP":"Yes; As client","Backup current, max.":"2.1 mA","Backup current, typ.":"370 µA; Valid up to 40°C","HW functional status":"1","ISO-on-TCP (RFC1006)":"Yes; Via integrated PROFINET interface or CP 443-1 and loadable FBs","integrated RAM, max.":"48 Mbyte","Consistent Data, Max.":"244 byte","Integrated (For Data)":"16 Mbyte","Number of breakpoints":"4","Number of connections":"120","Number of startup OBs":"2; OB 100, 102","Open IE communication":"Yes","PCS 7 process objects":"100 ... approx. 2 600, adjustable with System Expansion Card","Retentivity available":"Yes","Of Which In Line, Max.":"250","PROFINET IO Controller":"Yes","S7 basic communication":"No","System functions (SFC)":"see instruction list","Status/control variable":"Yes","Symbol-related messages":"No","Transmission rate, max.":"100 Mbit/s","User data per job, max.":"8 kbyte","Design of PLC basic unit":"with conformal coating","For Bit Operations, Typ.":"7.5 ns","Integrated (For Program)":"16 Mbyte","Number of DPV1 alarm OBs":"3; OB 55-57","Number of clock memories":"8; in 1 memory byte","Number of free cycle OBs":"1; OB 1","Number of time alarm OBs":"8; OB 10-17","Process control messages":"Yes","For Word Operations, Typ.":"7.5 ns","Global data communication":"No","Number of DP slaves, max.":"96","Number of delay alarm OBs":"4; OB 20-23","Number of variables, max.":"70","PROFIBUS and Ethernet CPs":"11; Of which max. 10 CP as DP master","Plug-in interface modules":"Synchronization modules 6AG1960-1AA06-7XA0 or 6AG1960-1AB06-7XA0","Hardware clock (real-time)":"Yes","Number of other interfaces":"2; 2x synchronization","Number of RS 485 interfaces":"1; PROFIBUS DP","Number of connections, max.":"118","Number of process alarm OBs":"8; OB 40-47","Process diagnostic messages":"Yes","S7 communication, as client":"Yes","S7 communication, as server":"Yes","User data consistency, max.":"1 024 byte","from interface 5 V DC, max.":"90 mA; At the DP interface","Retentive And Synchronizable":"Yes","System function blocks (SFB)":"see instruction list","User data per DP slave, max.":"244 byte","Number of PROFINET interfaces":"2","additional within an error OB":"2","reserved for OP communication":"1","reserved for PG communication":"1","Keep-alive function, supported":"Yes","Number of cyclic interrupt OBs":"9; OB 30-38 (= Process Tasks)","Number of expansion units, max.":"21; S7-400 expansion devices","Number of synchronous error OBs":"2; OB 121, 122","from backplane bus 5 V DC, max.":"2.4 A","from backplane bus 5 V DC, typ.":"2 A","For Fixed Point Arithmetic, Typ.":"7.5 ns","Number of asynchronous error OBs":"9; OB 80-88","from backplane bus 24 V DC, max.":"150 mA; DP interface","Number of subprocess images, max.":"15","Supports protocol for PROFINET IO":"Yes","Deviation per day (buffered), max.":"1.7 s; Power off","For Floating Point Arithmetic, Typ.":"15 ns","Number of connectable IM 460s, max.":"6","Number of connectable IM 463s, max.":"4; Single mode only","Number of slots per interface, max.":"1 632","Switchover time on line break, typ.":"200 ms","Activation/deactivation of DP slaves":"No","CiR synchronization time, basic load":"60 ms","Deviation per day (unbuffered), max.":"8.6 s; Power on","Number of stations in the ring, max.":"50","Activation/deactivation of IO Devices":"No","Output current of the interface, max.":"150 mA","Device replacement without swap medium":"Yes","Number of connectable IO Devices, max.":"250","Number of connectable IMs (total), max.":"6","Automatic Detection Of Transmission Rate":"Yes; Autosensing","Number of industrial Ethernet interfaces":"2","Feeding of external backup voltage to CPU":"No","Local port numbers used at the system end":"0, 20, 21, 25, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535","average processing time of PCS 7 typicals":"110 µs; with APL Typicals","Change of IP address at runtime, supported":"No","Limit class A, for use in industrial areas":"Yes","simultaneously active Alarm-S blocks, max.":"1 000; Simultaneously active alarm_S/SQ blocks or alarm_D/DQ blocks","CiR synchronization time, time per I/O byte":"0 µs","Installation altitude above sea level, max.":"5 000 m","Limit class B, for use in residential areas":"No","User program protection/password protection":"Yes","Number of connectable IO Devices for RT, max.":"250","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","User data per job (of which consistent), max.":"240 byte","Several Passive Connections Per Port, Supported":"Yes","Number of connectable OPs with message processing":"119; When using Alarm_S/SQ and Alarm_D/DQ","Direct data exchange (slave-to-slave communication)":"No","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m); with \"F-System\" applications max. +2 000 m above sea level permissible","Number of connectable OPs without message processing":"119","Number of login stations for message functions, max.":"119; Max. 119 with Alarm_S and Alarm_D (OPs); max. 12 with Alarm_8 and Alarm_P (e.g. WinCC)","Retentive data area (incl. timers, counters, flags), max.":"Total working and load memory (with backup battery)","Number of simultaneous AG-SEND/AG-RECV orders per CPU, max.":"64/64","IO Devices changing during operation (partner ports), supported":"No","Number of instances for alarm 8 and S7 communication blocks, max.":"10 000","Number of archives that can log on simultaneously (SFB 37 AR_SEND)":"64","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/73c226773fcdf0d206816d5a5dd882d6.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=566938&mlfb=6AG1410-5HX08-7AB0"},"ai":{"faq":[{"question":"What are the exact interfaces on the 6AG1410-5HX08-7AB0?","answer":"The CPU includes an integrated PROFINET interface supporting UDP and TCP/IP, plus a PROFIBUS DPV1 interface. MODBUS is available via an add-on module."},{"question":"How can I order the 6AG1410-5HX08-7AB0?","answer":"This part is quoted to order against your RFQ."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1410-5HX08-7AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1410-5HX08-7AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}