{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1432-1HF00-4AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1432-1HF00-4AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1432-1HF00-4AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1432-1HF00-4AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS SM 432 analog output module, 6AG1432-1HF00-4AB0, 8 channels, voltage and current outputs, -40 to 70 °C extended temperature range, 24 V DC.","salesMarkdown":"## 8-channel analog output for harsh environments The 6AG1432-1HF00-4AB0: It provides 8 analog output channels, each configurable for voltage signals (0 to 10 V, 1 to 5 V, -10 V to +10 V) or current signals (0 to 20 mA, 4 to 20 mA, -20 mA to +20 mA). ## Signal ranges and load drive Voltage outputs drive loads down to 1 kΩ minimum resistance, with short-circuit protection limiting output current to 30 mA max. Current outputs drive loads up to 500 Ω (600 Ω if common-mode voltage is reduced below 1 V), with a no-load voltage of 19 V max. Conversion time per channel is 420 µs in the 1 to 5 V and 4 to 20 mA ranges, and 300 µs in all other ranges. Resolution is 13 bits including sign bit. ## Power and isolation The module draws 150 mA max from the 5 V DC backplane bus and up to 200 mA from the 24 V DC load supply (400 mA at rated load). Typical power loss is 9 W. Channel-to-backplane bus isolation is provided; channel-to-channel isolation is not. Isolation is tested at 2120 V DC between bus and L+/M, and 707 V DC between the analog part and L+/M. Reverse polarity protection is included on the supply input.","metaTitle":"Siemens 6AG1432-1HF00-4AB0 SIPLUS SM 432, 8 Analog Outputs","metaDescription":"Siemens SIPLUS SM 432 analog output module, 8 channels, voltage and current outputs, -40 to 70 °C extended temp range. Active production, available to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"NRND","categoryPath":["Industrial PCs"],"specifications":{"Max.":"70 °C","Min.":"-40 °C","Depth":"210 mm","Width":"25 mm","title":"6AG1432-1HF00-4AB0","Height":"290 mm","0 to 10 V":"Yes","0 to 20 mA":"Yes","1 V to 5 V":"Yes","description":"SIPLUS S7-400 SM 432 8AQ based on 6ES7432-1HF00-0AB0 with conformal coating, 0…+60 °C,","4 mA to 20 mA":"Yes","-10 V to +10 V":"Yes","Shielded, Max.":"200 m","Weight, approx.":"650 g","lifecycle_stage":"current","-20 mA to +20 mA":"Yes","Power loss, typ.":"9 W","Rated value (DC)":"24 V","For Inductive Load":"0.5 ms","For Resistive Load":"0.1 ms","For Capacitive Load":"3.5 ms","Between The Channels":"No","Diagnostics function":"No","Isolation tested with":"2 120 V DC between bus and L+/M; 2 120 V DC between bus and analog part; 500 V DC between bus and local ground; 707 V DC between analog part and L+/M; 2 120 V DC between analog part and local ground; 2 120 V DC between L+/M and local ground","Number of analog outputs":"8","With Current Outputs, Max.":"500 Ω; 600 ohms if common-mode-voltage reduced to <1 V","With Voltage Outputs, Min.":"1 kΩ","Reverse polarity protection":"Yes","Conversion time (per channel)":"420 µs; 420 µs in the ranges 1 to 5 V and 4 to 20 mA; 300 µs in all ranges","from backplane bus 5 V DC, max.":"150 mA","Current output, no-load voltage, max.":"19 V","Between The Channels And Backplane Bus":"Yes","Current, relative to output range, (+/-)":"0.5 %; ±20 mA, 0 to 20 mA","Voltage output, short-circuit protection":"Yes","Voltage, relative to output range, (+/-)":"0.5 %; ±10 V, 0 to 10 V, 1 to 5 V","Installation altitude above sea level, max.":"5 000 m","Voltage output, short-circuit current, max.":"30 mA","With Voltage Outputs, Capacitive Load, Max.":"1 µF","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Resolution with overrange (bit including sign), max.":"13 bit","from supply and load voltage L+ (without load), max.":"200 mA; at rated load: max. 400 mA","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/804123e95e3e43256c2d6ece5dddf655.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=158693&mlfb=6AG1432-1HF00-4AB0"},"ai":{"faq":[{"question":"What is the difference between 6AG1432-1HF00-4AB0 and 6ES7432-1HF00-0AB0?","answer":"The 6AG1432-1HF00-4AB0 is the SIPLUS extended-temperature variant of the standard SM 432 module 6ES7432-1HF00-0AB0."},{"question":"What output signal ranges does 6AG1432-1HF00-4AB0 support?","answer":"The module supports voltage outputs: 0 to 10 V, 1 to 5 V, and -10 V to +10 V. Current outputs: 0 to 20 mA, 4 to 20 mA, and -20 mA to +20 mA."},{"question":"Where can I buy 6AG1432-1HF00-4AB0?","answer":"Submit a request with your target quantity and delivery timeline for a current price and availability confirmation."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1432-1HF00-4AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1432-1HF00-4AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-20T14:41:02.429Z","lastPublished":"2026-07-20T14:41:02.429Z","indexable":true}}