{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1434-2BA20-7AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1434-2BA20-7AA0","canonicalUrl":"https://aoctrl.com/siemens/6AG1434-2BA20-7AA0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1434-2BA20-7AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SITOP PSU8200, 6AG1434-2BA20-7AA0, 24-28 V DC/10 A regulated power supply, 3-phase 400-500 V AC input, 91% efficiency, EN 55022 Class B.","salesMarkdown":"The 6AG1434-2BA20-7AA0: Load transient response is tight: 4 ms typical for a 10-to-90% step and 3 ms for a 100-to-50% step, so the supply handles sudden motor or solenoid pulls without dropping out. Galvanic isolation meets SELV per EN 60950-1 and EN 50178, with a safety extra-low voltage output. That means the 24 V bus is isolated from the mains — useful for protecting downstream controls from line transients. ## Mounting, wiring, and feeder protection Snaps onto DIN rail EN 60715 35×7.5/15. Enclosure is 70 mm wide × 125 mm high × 120 mm deep — fits a standard 4-module slot. Input terminals: one screw clamp per phase (, L2, L3) and PE, accepting 0.05–2.5 mm². Output: two screw terminals each for + and -, 0.2–2.5 mm². Auxiliary alarm relay terminals also provided (13, 14, 0.2–2.5 mm²). Listed as current-production (active); no end-of-life notice. The PSU carries CE marking and meets EN 55022 Class B for conducted and radiated emissions — low enough for residential limits, so it won't hash up nearby sensors or comms lines in an industrial cabinet. Compatible with SITOP add-on modules: redundancy, buffer, selectivity module, and DC UPS. If your BOM calls for a single-source power rail, this PSU slots into that ecosystem.","metaTitle":"Siemens 6AG1434-2BA20-7AA0 SITOP PSU8200 10A Power Supply","metaDescription":"SITOP PSU8200 power supply, 24-28 V DC/10 A rated (16 A max), 400-500 V AC 3-phase input, 91% efficiency, EN 55022 Class B, DIN rail mount. Active production.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Industrial PCs"],"specifications":{"title":"6AG1434-2BA20-7AA0","Maximum":"16 A","Typical":"13 A","At Input":"L1, L2, L3, PE: 1 screw terminal each for 0.05 ... 2.5 mm² single-core/finely stranded","At Output":"+, -: 2 screw terminals each for 0.2 ... 2.5 mm²","CE marking":"Yes","Rated Range":"0 ... 10 A; 12 A up to +45°C; +60 ... +70 °C: Derating 5%/K","Rated Value":"10 A","description":"SIPLUS PS PSU300S 10A based on 6EP1434-2BA20 with conformal coating, -40…+70 °C, start up -25 °C, stabilized power supply input: 400-500 V 3 AC output: 24 V DC/ 10 A","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","In The Feeder":"Required: 3-pole connected miniature circuit breaker 3 ... 16 A characteristic C or circuit breaker 3RV2011-1DA10 (setting 3 A) or 3RV2711-1DD10 (UL 489-listed, DIVQ)","Initial Value":"340 V","Line Frequency":"47 ... 63 Hz","MTBF at 40 °C":"500 000 h","lifecycle_stage":"current","Fastening Method":"Snaps onto DIN rail EN 60715 35x7.5/15","Full-Scale Value":"550 V","I2t value maximum":"0.5 A²·s","Other Information":"Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)","Galvanic Isolation":"Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178, transformer acc. to EN 61558-2-16","Maximum Rated Value":"500 V","Minimum Rated Value":"400 V","protection class IP":"IP20","Bridging Of Equipment":"Yes","Efficiency In Percent":"91 %","Depth Of The Enclosure":"120 mm","Electrical Accessories":"redundancy module, buffer module, selectivity module, DC UPS","For Auxiliary Contacts":"13, 14 (alarm signal): 1 screw terminal each for 0.2 ... 2.5 mm²","Mechanical Accessories":"Device identification label 20 mm × 7 mm, pale turquoise 3RT1900-1SB20","Response Delay Maximum":"1.5 s","Width Of The Enclosure":"70 mm","Height Of The Enclosure":"125 mm","Voltage Curve At Output":"Controlled, isolated DC voltage","For Emitted Interference":"EN 55022 Class B","Type Of Signal At Output":"Relay contact (NO contact, rating 60 V DC/ 0.3 A) for \"24 V OK\"","Adjustable Output Voltage":"24 ... 28 V","For Interference Immunity":"EN 61000-6-2","Load Step 10 To 90% Typical":"4 ms","Load Step 90 To 10% Typical":"4 ms","During Storage And Transport":"-40 ... +85 °C","Load Step 100 To 50% Typical":"3 ms","Load Step 50 To 100% Typical":"3 ms","at rated input voltage 400 V":"0.7 A","at rated input voltage 500 V":"0.6 A","Supplied Active Power Typical":"240 W","Type Of Electrical Connection":"screw-type terminals","at output 1 at DC rated value":"24 V","For Mains Harmonics Limitation":"EN 61000-3-2","Type Of Output Voltage Setting":"via potentiometer; max. 240 W","Design Of Input Wide Range Input":"Yes","Type Of The Power Supply Network":"3-phase AC","output voltage at DC rated value":"24 V","Design Of Short-Circuit Protection":"Constant current characteristic","On Slow Fluctuation Of Ohm Loading":"0.15 %","Operating Resource Protection Class":"Class I","Design Of The Overvoltage Protection":"protection against overvoltage in case of internal fault Vout < 35 V","Display Version For Normal Operation":"Green LED for 24 V OK","On Slow Fluctuation Of Input Voltage":"0.1 %","Relative Overall Tolerance Of The Voltage":"3 %","Operating Condition Of The Mains Buffering":"at Vin = 400 V","Product Function Output Voltage Adjustable":"Yes","Property Of The Output Short-Circuit Proof":"Yes","Galvanic Isolation Between Input And Output":"Yes","Behavior Of The Output Voltage When Switching On":"Overshoot of Vout < 5 %","In Horizontal Mounting Position During Operation":"-40; Startup @ -25 °C ... +70 °C; with natural convection","Overcurrent Overload Capability In Normal Operation":"overload capability 150 % Iout rated up to 5 s/min","current limitation of inrush current at 25 °C maximum":"20 A","Installation Altitude At Height Above Sea Level Maximum":"6 000 m","Product Feature Of The Enclosure Housing Can Be Lined Up":"Yes","Chemical Resistance To Commercially Available Cooling Lubricants":"Yes; incl. diesel and oil droplets in the air","At Rated Output Voltage For Rated Value Of The Output Current Typical":"23 W","Number Of Parallel-Switched Equipment Resources For Increasing The Power":"2","Ambient Condition Relating To Ambient Temperature - Air Pressure - Installation Altitude":"In case of operation at altitudes of 2000 - 6000 m above sea level: Output power derating of -7.5 %/1000 m or reduction of the ambient temperature by 5 K/1000 m","Buffering Time For Rated Value Of The Output Current In The Event Of Power Failure Minimum":"7 ms","Relative Control Precision Of The Output Voltage With Rapid Fluctuation Of The Input Voltage By +/- 15% Typical":"1 %","product conformity of the coating Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal Coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/54d14b98a8ce97a3baf31237cf3be522.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1089258&mlfb=6AG1434-2BA20-7AA0"},"ai":{"faq":[{"question":"What is the maximum output current I can draw continuously?","answer":"The continuous rated current is 10 A. At ambient temperatures up to 45 °C you can draw 12 A. Above 60 °C the output must be derated by 5% per K. The 16 A figure is a dynamic maximum, not a steady-state rating."},{"question":"Can I adjust the output voltage?","answer":"Yes, the output voltage is adjustable from 24 to 28 V DC, allowing line-drop compensation for long cable runs."},{"question":"What upstream protection does this supply require?","answer":"A 3-pole miniature circuit breaker (3–16 A, characteristic C) or a Siemens 3RV2011 (setting 3 A) is required in the feeder. The PSU has no internal branch-circuit protection."},{"question":"Does this power supply have galvanic isolation?","answer":"Yes, it provides safety extra-low voltage (SELV) output per EN 60950-1 and EN 50178, with transformer isolation per EN 61558-2-16."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1434-2BA20-7AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1434-2BA20-7AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}