{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1436-2BA10-7AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1436-2BA10-7AA0","canonicalUrl":"https://aoctrl.com/siemens/6AG1436-2BA10-7AA0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1436-2BA10-7AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SITOP, 6AG1436-2BA10-7AA0, 20 A rated adjustable 24–28 V DC power supply, 91 % efficiency, IP20, DIN-rail mount.","salesMarkdown":"## SITOP 6AG1436-2BA10-7AA0 at a glance This Siemens SITOP power supply delivers a controlled, isolated 24–28 VDC adjustable output at a full-scale 20 A, with a rated range of 0–20 A and 91% efficiency at 400–500 VAC input (47–63 Hz). Galvanic isolation to EN 60950-1 and EN 50178 ensures safe low-voltage outputs; the unit carries CE marking and meets EN 55022 Class B for emissions and EN 61000-6-2 for immunity. MTBF is rated 500 000 h at 40 °C, with a typical current draw of 1 mA (max 3.5 mA). ## Panel mounting and clearances Snaps onto DIN-rail EN 60715 (35×7.5/15). Enclosure dimensions: width 90 mm, height 145 mm, depth 150 mm. Adequate airflow requires 40 mm clearance above and below the unit; side clearance is 0 mm — modules can be abutted in a row without spacing. Protection class IP20 — suitable for clean, dry control cabinets only. ## Connections and accessories Input (, L2, L3, PE) accepts 0.5–4 mm² single-core or finely stranded wire per screw terminal. Output (+/−) accepts 0.2–4 mm². A separate alarm relay (NO contact) is on terminals 13–14. Electrical accessories listed by the manufacturer include a redundancy module, buffer module, selectivity module, and DC UPS for extended hold-up or dual-feed configurations. The feeder circuit must be protected by a 3-pole miniature circuit breaker (6–16 A, characteristic C) or a Siemens 3RV circuit breaker (setting 3 A) per the spec. This is an active, current-production part. No end-of-life or last-time-buy notice applies.","metaTitle":"Siemens 6AG1436-2BA10-7AA0 SITOP Power Supply, 20 A","metaDescription":"Active Siemens SITOP 6AG1436-2BA10-7AA0, 20 A rated output, adjustable 24–28 VDC, 91% efficiency, IP20, EN 55022 Class B. Order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Industrial PCs"],"specifications":{"Top":"40 mm","Left":"0 mm","Right":"0 mm","title":"6AG1436-2BA10-7AA0","Bottom":"40 mm","Maximum":"3.5 mA","Typical":"1 mA","At Input":"L1, L2, L3, PE: 1 screw terminal each for 0.5 ... 4 mm² single-core/finely stranded","At Output":"+, -: 2 screw terminals each for 0.2 ... 4 mm²","CE marking":"Yes","Rated Range":"0 ... 20 A","Rated Value":"20 A","description":"SIPLUS PS PSU300S 20 A based on 6EP1436-2BA10 with conformal coating, -40…+70 °C, stabilized power supply input: 400-500 V 3 AC output: 24 V DC/20 A","1 Rated Value":"50 Hz","2 Rated Value":"60 Hz","In The Feeder":"Required: 3-pole connected miniature circuit breaker 6 ... 16 A characteristic C or circuit breaker 3RV2011-1DA10 (setting 3 A) or 3RV2711-1DD10 (UL 489-listed, DIVQ)","Initial Value":"340 V","Line Frequency":"47 ... 63 Hz","MTBF at 40 °C":"500 000 h","lifecycle_stage":"current","Fastening Method":"Snaps onto DIN rail EN 60715 35x7.5/15","Full-Scale Value":"550 V","I2t value maximum":"0.9 A²·s","Other Information":"Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)","Galvanic Isolation":"Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178, transformer acc. to EN 61558-2-16","Maximum Rated Value":"500 V","Minimum Rated Value":"400 V","protection class IP":"IP20","Bridging Of Equipment":"Yes","Efficiency In Percent":"91 %","Depth Of The Enclosure":"150 mm","Electrical Accessories":"redundancy module, buffer module, selectivity module, DC UPS","For Auxiliary Contacts":"13, 14 (alarm signal): 1 screw terminal each for 0.05 ... 2.5 mm²","Mechanical Accessories":"Device identification label 20 mm × 7 mm, pale turquoise 3RT1900-1SB20","Response Delay Maximum":"1.5 s","Width Of The Enclosure":"90 mm","Height Of The Enclosure":"145 mm","Voltage Curve At Output":"Controlled, isolated DC voltage","For Emitted Interference":"EN 55022 Class B","Type Of Signal At Output":"Relay contact (NO contact, rating 60 V DC/ 0.3 A) for \"24 V OK\"","Adjustable Output Voltage":"24 ... 28 V","For Interference Immunity":"EN 61000-6-2","During Storage And Transport":"-40 ... +85 °C","Load Step 100 To 50% Typical":"2 ms","Load Step 50 To 100% Typical":"2 ms","at rated input voltage 400 V":"1.2 A","at rated input voltage 500 V":"1 A","Supplied Active Power Typical":"480 W","Type Of Electrical Connection":"screw-type terminals","at output 1 at DC rated value":"24 V","For Mains Harmonics Limitation":"EN 61000-3-2","Type Of Output Voltage Setting":"via potentiometer; max. 480 W","Design Of Input Wide Range Input":"Yes","Type Of The Power Supply Network":"3-phase AC","output voltage at DC rated value":"24 V","At Short-Circuit During Operation":"100 ms","Design Of Short-Circuit Protection":"Electronic shutdown, automatic restart","On Slow Fluctuation Of Ohm Loading":"1 %","Operating Resource Protection Class":"Class I","Design Of The Overvoltage Protection":"protection against overvoltage in case of internal fault Vout < 35 V","Display Version For Normal Operation":"Green LED for 24 V OK","On Slow Fluctuation Of Input Voltage":"0.5 %","On Short-Circuiting During The Start-Up":"100 ms","At Short-Circuit During Operation Typical":"35 A","Relative Overall Tolerance Of The Voltage":"3 %","Operating Condition Of The Mains Buffering":"at Vin = 400 V","Product Function Output Voltage Adjustable":"Yes","Property Of The Output Short-Circuit Proof":"Yes","Galvanic Isolation Between Input And Output":"Yes","On Short-Circuiting During The Start-Up Typical":"35 A","Behavior Of The Output Voltage When Switching On":"No overshoot of Vout (soft start)","In Horizontal Mounting Position During Operation":"-40 ... +60 °C; with natural convection","Overcurrent Overload Capability In Normal Operation":"overload capability 150 % Iout rated up to 5 s/min","current limitation of inrush current at 25 °C maximum":"36 A","Installation Altitude At Height Above Sea Level Maximum":"6 000 m","Product Feature Of The Enclosure Housing Can Be Lined Up":"Yes","Chemical Resistance To Commercially Available Cooling Lubricants":"Yes; incl. diesel and oil droplets in the air","At Rated Output Voltage For Rated Value Of The Output Current Typical":"47 W","Number Of Parallel-Switched Equipment Resources For Increasing The Power":"2","Ambient Condition Relating To Ambient Temperature - Air Pressure - Installation Altitude":"In case of operation at altitudes of 2000 - 6000 m above sea level: Output power derating of -7.5 %/1000 m or reduction of the ambient temperature by 5 K/1000 m","Buffering Time For Rated Value Of The Output Current In The Event Of Power Failure Minimum":"6 ms","Relative Control Precision Of The Output Voltage With Rapid Fluctuation Of The Input Voltage By +/- 15% Typical":"3 %","product conformity of the coating Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal Coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$434.34","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/744d5ad6c432ef23d74a9ac70ff72948.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=229212&mlfb=6AG1436-2BA10-7AA0"},"ai":{"faq":[{"question":"What are the required clearances around this power supply?","answer":"Top and bottom clearance must be 40 mm; left and right clearance can be 0 mm — units can be mounted side-by-side without gaps."},{"question":"What compliance markings does it carry?","answer":"CE marking is present. Emissions meet EN 55022 Class B; immunity meets EN 61000-6-2. Galvanic isolation is per EN 60950-1 and EN 50178."},{"question":"How do I source this part?","answer":"It is a standard active stock item. Submit an RFQ for current lead time and pricing; we can quote firm quantities against your delivery schedule."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1436-2BA10-7AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1436-2BA10-7AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}