{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1505-0RA00-7AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1505-0RA00-7AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1505-0RA00-7AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1505-0RA00-7AB0","rawCanonicalId":null},"summary":{"shortDescription":"SIPLUS S7-1500 PS 1505 60W system power supply, 24/48/60 V DC, conformal coated, -40…+70 °C, for S7-1500 backplane bus.","salesMarkdown":"## Where the rating gates the fit The 6AG1505-0RA00-7AB0: At +60°C ambient, the 60W backplane feed drops to 30W. If your rack draws more than that above +60°C, you need to derate or add a second supply. Input tolerance accepts 19.2 to 72 VDC static, 18.5 to 75.5 VDC dynamic. Built-in reverse polarity protection and reinforced isolation to 230V AC. The 147×70×129mm footprint, IP20, and protective-earth class I keep the panel layout identical to the standard S7-1500 power supply – a straight swap. ## Sourcing reality confirms active — no PCN, no NRND marker. That means it's a standard BOM line, not a scavenger hunt. Expect quoted lead times in line with any current-active Siemens SIPLUS order. If you're swapping in for a failed standard PS 1505 in a coated panel, this is the right drop-in; the conformal coating and temp range are the only differences.","metaTitle":"Siemens 6AG1505-0RA00-7AB0 SIPLUS S7-1500 PS, 60W, 24/48/60V","metaDescription":"Active SIPLUS S7-1500 system power supply for backplane bus. Conformal coating, -40 to +70°C, 24/48/60VDC, 60W. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Max.":"70 °C","Min.":"-40 °C","Depth":"129 mm","Width":"70 mm","title":"6AG1505-0RA00-7AB0","Height":"147 mm","description":"SIPLUS S7-1500 PS 1505 60W 24/48/60V DC based on 6ES7505-0RA00-0AB0 with conformal coating, -40…+70 °C, start up -25 °C, system power supply supplies the backplane bus of the S7-1500 with operating voltage","For Uprating":"Yes","Weight, approx.":"600 g","lifecycle_stage":"current","Rated value (DC)":"24 V / 48 V / 60 V","Status indicator":"Yes","Primary/Secondary":"Yes; Electrical isolation for 230 V AC (reinforced isolation)","Isolation tested with":"2 500 V DC/2 s (routine test)","Redundancy capability":"Yes","Rated value at 48 V DC":"1.5 A","Rated value at 60 V DC":"1.2 A","IP degree of protection":"IP20","Short-circuit protection":"Yes","Equipment protection class":"I, with protective conductor","Reverse polarity protection":"Yes","Infeed power to the backplane bus":"60 W; > +60 °C max. power input 30 W","permissible range, lower limit (DC)":"19.2 V; Static 19.2 V, dynamic 18.5 V","permissible range, upper limit (DC)":"72 V; Static 72 V, dynamic 75.5 V","Power loss at nominal rating conditions":"12 W","Mains/voltage failure stored energy time":"20 ms","Installation altitude above sea level, max.":"5 000 m","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$642.62","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/b66b3a0be54bf744b38d08089e852c0c.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=287855&mlfb=6AG1505-0RA00-7AB0"},"ai":{"faq":[{"question":"What is the operating temperature range?","answer":"Rated -40°C to +70°C ambient. Start-up from -25°C."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1505-0RA00-7AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1505-0RA00-7AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}