{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1513-1AL00-2AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1513-1AL00-2AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1513-1AL00-2AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1513-1AL00-2AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 6AG1513-1AL00-2AB0 S7-1500 SIPLUS CPU, extended temperature -40..70 °C, 300 kbyte program memory, MRP redundancy manager.","salesMarkdown":"The 6AG1513-1AL00-2AB0: Supports MRP as redundancy manager with up to 50 devices in the ring, which eliminates the need for a separate ring manager switch in a ring topology. Web server and HTTPS are standard, allowing custom diagnostics pages; MODBUS TCP is natively supported without an additional module. IRT, LLDP, SNMP, and DHCP (disabled) round out the network stack. ## Programming languages and integration The CPU can be programmed in LAD, FBD, STL, SCL, and GRAPH (as of STEP 7 V12 SP1). PID control includes for valve applications with integrated optimization. S7 routing is enabled, and up to 6 communication modules (PROFINET + PROFIBUS) can be added. Physical footprint is 35 mm wide x 147 mm high x 129 mm deep, fitting the standard S7-1500 mounting profile. Integrated PROFINET interface runs at 100 Mbps. Specified for harsh-environment projects: cold storage, outdoor cabinets, or non-conditioned factory spaces where the standard 0–60 °C CPU would require additional climate control. The MODBUS TCP and MRP features simplify retrofit into existing plant networks without extra gateways.","metaTitle":"Siemens 6AG1513-1AL00-2AB0 S7-1500 SIPLUS CPU MRP -40..70°C","metaDescription":"Ruggedized S7-1500 CPU for harsh environments, rated -40 to 70 °C. Features MRP, web server, MODBUS TCP, 300 kbyte program memory. Order to spec.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"DCP":"Yes","FBD":"Yes","I2t":"0.34 A²·s","IRT":"Yes","LAD":"Yes","MRP":"Yes; as MRP redundancy manager and/or MRP client; max. number of devices in the ring: 50","SCL":"Yes","STL":"Yes","UDP":"Yes","DHCP":"No","HTTP":"Yes; Standard and user-defined pages","LLDP":"Yes","Max.":"70 °C","Min.":"-40 °C","SNMP":"Yes","Type":"Hardware clock","Depth":"129 mm","GRAPH":"Yes; As of STEP 7 V12 SP1","HTTPS":"Yes; Standard and user-defined pages","Width":"35 mm","title":"6AG1513-1AL00-2AB0","Height":"147 mm","Inputs":"32 kbyte; All inputs are in the process image","MODBUS":"Yes; MODBUS TCP","Number":"Any (only limited by the main memory)","TCP/IP":"Yes","Via CM":"6; A maximum of 6 CMs (PROFINET + PROFIBUS) can be inserted in total","Outputs":"32 kbyte; All outputs are in the process image","Present":"Yes","100 Mbps":"Yes","ERROR LED":"Yes","MAINT LED":"Yes","PID_3Step":"Yes; PID controller with integrated optimization for valves","Supported":"Yes","Variables":"Inputs, outputs, memory bits, DB, times, counters","Adjustable":"Yes","Integrated":"1","S7 routing":"Yes","Size, max.":"300 kbyte","Web server":"Yes","Backup time":"6 wk; At 40 °C ambient temperature, typically","Lower Limit":"adjustable minimum cycle time","PID_Compact":"Yes; Universal PID controller with integrated optimization","PROFIenergy":"Yes","Single step":"No","Upper Limit":"adjustable maximum cycle time","description":"***SPARE PART*** ***Spare part*** SIPLUS S7-1500 CPU 1513-1 PN -40...+60°C start up -20°C with conformal coating based on 6ES7513-1AL00-0AB0. Central processing unit with Work memory 300 KB for program and 1.5 MB for data, 1st interface, PROFINET IRT with 2-port switch, 40 ns bit performance, SIMATIC Memory Card required -40...+60°C with conformal coating based on 6ES7513-1AL00-0AB0","Autocrossing":"Yes","Equidistance":"Yes","Number, max.":"16 kbyte","RUN/STOP LED":"Yes","Status block":"Yes; Up to 16 simultaneously","in AS, slave":"Yes","in AS, master":"Yes","Motion Control":"Yes","Number of keys":"6","Program alarms":"Yes","Updating times":"The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data","Autonegotiation":"Yes","Copy protection":"Yes","Inputs (volume)":"8 kbyte","Number of ports":"2","Weight, approx.":"430 g","lifecycle_stage":"current","Block protection":"Yes","Isochronous mode":"Yes","Maintenance-Free":"Yes","Media redundancy":"Yes","Outputs (volume)":"8 kbyte","Power loss, typ.":"5.7 W","RJ 45 (Ethernet)":"Yes","Data length, max.":"1 472 byte","Integrated Switch":"Yes","Number of PtP CMs":"the number of connectable PtP CMs is only limited by the number of available slots","Forcing, variables":"Inputs, outputs","High-speed counter":"Yes","PROFINET IO Device":"Yes","Per Priority Class":"24","Retentivity preset":"No","PG/OP communication":"Yes","Prioritized startup":"Yes; Max. 32 PROFINET devices","on Ethernet via NTP":"Yes","ISO-on-TCP (RFC1006)":"Yes","Inrush current, max.":"1.9 A; Rated value","Mode selector switch":"1","Number of IO modules":"2 048","Password for display":"Yes","Screen diagonal [cm]":"3.45 cm","Integrated (For Data)":"1.5 Mbyte","Number of lines, max.":"1","Number of startup OBs":"100","Open IE communication":"Yes","SIMATIC communication":"Yes","For Send Cycle Of 1 Ms":"1 ms to 512 ms","For Send Cycle Of 2 Ms":"2 ms to 512 ms","For Send Cycle Of 4 Ms":"4 ms to 512 ms","Modules per rack, max.":"32; CPU + 31 modules","Of Which In Line, Max.":"128","PROFINET IO Controller":"Yes","Retentivity adjustable":"Yes","Type of supply voltage":"24 V DC","Deviation per day, max.":"10 s; Typ.: 2 s","Status/control variable":"Yes","User data per job, max.":"BSEND/BRCV: 64 KB; PUT/GET: 960 bytes","For Bit Operations, Typ.":"40 ns","Integrated (For Program)":"300 kbyte","Number of DPV1 alarm OBs":"3","Number of blocks (total)":"2 000","Number of clock memories":"8; 8 clock memory bit, grouped into one clock memory byte","Number of free cycle OBs":"100","Number of time alarm OBs":"20","Of Which Powerfail-Proof":"250","Per Priority Class, Max.":"64 kbyte; max. 16 KB per block","For Send Cycle Of 250 μS":"250 µs to 128 ms","For Send Cycle Of 500 μS":"500 µs to 256 ms","For Word Operations, Typ.":"48 ns","Number of delay alarm OBs":"20","Number of variables, max.":"1 000","Number of connections, max.":"128","Number of process alarm OBs":"50","S7 communication, as client":"Yes","S7 communication, as server":"Yes","Vertical Installation, Max.":"40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off","Vertical Installation, Min.":"-40 °C; = Tmin; startup @ -25 °C; startup display @ -20 °C","SIMATIC memory card required":"Yes","Connection display LINK TX/RX":"Yes","Horizontal Installation, Max.":"60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off","Horizontal Installation, Min.":"-40 °C; = Tmin; Startup @ -20 °C","Number of PROFINET interfaces":"1","Industrial Ethernet status LED":"Yes","Number of cyclic interrupt OBs":"20","Number of diagnostic alarm OBs":"1","Number of isochronous mode OBs":"1","Number of synchronous error OBs":"2","Of Which Status Variables, Max.":"200","For Fixed Point Arithmetic, Typ.":"64 ns","Number of asynchronous error OBs":"4","Number of distributed IO systems":"7","Number of positioning axes, max.":"6; Up to 6 axes in total (speed-controlled, positioning axis, external encoders) are supported","Of Which Control Variables, Max.":"200","Current consumption (rated value)":"0.7 A","Infeed power to the backplane bus":"10 W","Number of external encoders, max.":"6; Up to 6 axes in total (speed-controlled, positioning axis, external encoders) are supported","Number of subprocess images, max.":"32","Of which IO devices with IRT, max.":"64","Protection level: Write protection":"Yes","For Floating Point Arithmetic, Typ.":"256 ns","Number of IO Devices per tool, max.":"8","Plug-in (SIMATIC Memory Card), max.":"2 Gbyte","Switchover time on line break, typ.":"200 ms","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Number of stations in the ring, max.":"50","Number of speed-controlled axes, max.":"6; Up to 6 axes in total (speed-controlled, positioning axis, external encoders) are supported","Protection level: Complete protection":"Yes","Number of connectable IO Devices, max.":"128; In total, up to 256 distributed I/O devices can be connected via PROFIBUS or PROFINET","Protection level: Read/write protection":"Yes","Number of technology synchronous alarm OBs":"2","User program protection/password protection":"Yes","Number of configurable program messages, max.":"5 000","Number of connectable IO Devices for RT, max.":"128","Number of connections reserved for ES/HMI/web":"10","Number of simultaneously active program alarms":"500","Number of connections via integrated interfaces":"88","With IRT and parameterization of \"odd\" send cycles":"Update time = set \"odd\" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)","Power consumption from the backplane bus (balanced)":"5.5 W","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Number of login stations for message functions, max.":"32","Retentive data area (incl. timers, counters, flags), max.":"128 kbyte; Available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB","Number of IO Devices that can be simultaneously activated/deactivated, max.":"8"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2ed26864a4538689e263fb80d426fcbf.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=234000&mlfb=6AG1513-1AL00-2AB0"},"ai":{"faq":[{"question":"What programming languages does this CPU support?","answer":"It supports LAD, FBD, STL, SCL, and GRAPH (as of STEP 7 V12 SP1)."},{"question":"Does it support media redundancy (MRP)?","answer":"Yes, as MRP redundancy manager and/or MRP client with up to 50 devices in the ring."},{"question":"What is the ambient temperature range?","answer":"Rated for -40 °C to 70 °C operating temperature."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1513-1AL00-2AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1513-1AL00-2AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}