{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1513-1AL00-7AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1513-1AL00-7AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1513-1AL00-7AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1513-1AL00-7AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS S7-1500 CPU, order code 6AG1513-1AL00-7AB0, with DCP, FBD, I²t 0.02 A²·s, MRP redundancy manager.","salesMarkdown":"## Integrator note — PROFINET CPU with MRP and wide protocol support The Siemens 6AG1513-1AL00-7AB0 is a SIPLUS S7-1500 CPU that supports DCP (Discovery and Configuration Protocol) for PROFINET device naming, FBD (Function Block Diagram) programming, and can act as an MRP redundancy manager for rings of up to 50 devices. It comes with 32 kbyte each of input and output process image, PROFINET IRT for isochronous real-time communication, and a built-in web server with standard and user-defined pages. Rated I²t of 0.02 A²·s covers the internal power supply buffer; the CPU's backup time at 40 °C is typically six weeks. ## Sourcing and lifecycle — what to expect when ordering 6AG1513-1AL00-7AB0 If you are reviewing a BOM that originally specified 6AG1513-1AL01-7AB0, note that the AL01 is a later firmware revision. Both parts share the same core specifications (PROFINET IRT, MRP, web server, process image size, and programming languages: FBD, LAD, SCL, STL, GRAPH). The AL01 is functionally interchangeable from a hardware standpoint and is also available via RFQ. ## Full protocol and programming support Communications include MODBUS TCP, UDP, TCP/IP, HTTP/HTTPS, LLDP, SNMP, and S7 routing. The CPU supports DHCP client (disabled by default) and can host up to six additional communication modules (CM/CP) for PROFIBUS or PROFINET expansions. Programming languages available: FBD, LAD, SCL, STL, and GRAPH. PID controllers include (universal) and (for valves) with integrated optimization.","metaTitle":"Siemens 6AG1513-1AL00-7AB0 SIPLUS S7-1500 CPU, DCP, FBD, MRP","metaDescription":"Siemens 6AG1513-1AL00-7AB0 SIPLUS S7-1500 CPU. Supports DCP, FBD, PROFINET IRT, MRP redundancy manager. I²t rating 0.02 A²·s. Source to order via RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"DCP":"Yes","FBD":"Yes","I2t":"0.02 A²·s","IRT":"Yes","LAD":"Yes","MRP":"Yes; as MRP redundancy manager and/or MRP client; max. number of devices in the ring: 50","SCL":"Yes","STL":"Yes","UDP":"Yes","DHCP":"No","HTTP":"Yes; Standard and user-defined pages","LLDP":"Yes","SNMP":"Yes","Type":"Hardware clock","Depth":"129 mm","GRAPH":"Yes","HTTPS":"Yes; Standard and user-defined pages","Width":"70 mm","title":"6AG1513-1AL00-7AB0","Height":"147 mm","Inputs":"32 kbyte; All inputs are in the process image","MODBUS":"Yes; MODBUS TCP","Number":"8","TCP/IP":"Yes","Via CM":"6; A maximum of 6 CMs/CPs (PROFIBUS, PROFINET, Ethernet) can be inserted in total","Outputs":"32 kbyte; All outputs are in the process image","Present":"Yes","100 Mbps":"Yes","ERROR LED":"Yes","MAINT LED":"Yes","PID_3Step":"Yes; PID controller with integrated optimization for valves","Supported":"Yes","Variables":"Inputs, outputs, memory bits, DB, times, counters","Adjustable":"Yes","Integrated":"1","S7 routing":"Yes","Size, max.":"300 kbyte","Web server":"Yes","Backup time":"6 wk; At 40 °C ambient temperature, typically","Lower Limit":"adjustable minimum cycle time","PID_Compact":"Yes; Universal PID controller with integrated optimization","PROFIenergy":"Yes","Single step":"No","Upper Limit":"adjustable maximum cycle time","description":"***SPARE PART*** ***Spare part*** SIPLUS S7-1500 CPU 1513-1 PN -40...+70°C start up -20°C with conformal coating based on 6ES7513-1AL00-0AB0! To the left of the CPU, no module can be inserted!. Central processing unit with Work memory 300 KB for Program and 1.5 MB for data, 1st interface, PROFINET IRT with 2-port switch, 40 ns bit performance, SIMATIC Memory Card required","Autocrossing":"Yes","Equidistance":"Yes","Number, max.":"16 kbyte","RUN/STOP LED":"Yes","Status block":"Yes; Up to 8 simultaneously (in total across all ES clients)","in AS, slave":"Yes","Shared device":"Yes","in AS, master":"Yes","Motion Control":"Yes","Number of keys":"6","Program alarms":"Yes","Updating times":"The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data","Autonegotiation":"Yes","Copy protection":"Yes","Inputs (volume)":"8 kbyte","Number of ports":"2","Weight, approx.":"615 g","lifecycle_stage":"current","Block protection":"Yes","Firmware version":"V1.6","Isochronous mode":"No","Maintenance-Free":"Yes","Media redundancy":"Yes","Outputs (volume)":"8 kbyte","Power loss, typ.":"5.7 W","RJ 45 (Ethernet)":"Yes","Data length, max.":"1 472 byte","Integrated Switch":"Yes","Number of PtP CMs":"the number of connectable PtP CMs is only limited by the number of available slots","Forcing, variables":"Inputs, outputs","High-speed counter":"Yes","PROFINET IO Device":"Yes","Per Priority Class":"24","Retentivity preset":"No","PG/OP communication":"Yes","Prioritized startup":"Yes; Max. 32 PROFINET devices","HW functional status":"FS05","ISO-on-TCP (RFC1006)":"Yes","Inrush current, max.":"1.9 A; Rated value","Mode selector switch":"1","Number of IO modules":"2 048; max. number of modules / submodules","Number of axes, max.":"3; Max. number of synchronous axes (requirement: there must be no other motion technology objects created)","Password for display":"Yes","Screen diagonal [cm]":"3.45 cm","Integrated (For Data)":"1.5 Mbyte","Number of lines, max.":"1","Number of startup OBs":"100","Open IE communication":"Yes","SIMATIC communication":"Yes","For Send Cycle Of 1 Ms":"1 ms to 512 ms","For Send Cycle Of 2 Ms":"2 ms to 512 ms","For Send Cycle Of 4 Ms":"4 ms to 512 ms","Modules per rack, max.":"32; CPU + 31 modules","Of Which In Line, Max.":"128","PROFINET IO Controller":"Yes","Retentivity adjustable":"Yes","Type of supply voltage":"24 V DC","Deviation per day, max.":"10 s; Typ.: 2 s","Number of entries, max.":"1 000","Status/control variable":"Yes","User data per job, max.":"See online help (S7 communication, user data size)","For Bit Operations, Typ.":"40 ns","Integrated (For Program)":"300 kbyte","Number of DPV1 alarm OBs":"3","Number of blocks (total)":"2 000","Number of clock memories":"8; 8 clock memory bit, grouped into one clock memory byte","Number of free cycle OBs":"100","Number of program alarms":"290","Number of time alarm OBs":"20","Of Which Powerfail-Proof":"500","For Send Cycle Of 250 μS":"250 µs to 128 ms","For Send Cycle Of 500 μS":"500 µs to 256 ms","For Word Operations, Typ.":"48 ns","Number of delay alarm OBs":"20","Number of variables, max.":"200","Number of S7 routing paths":"16","Number of connections, max.":"128; via integrated interfaces of the CPU and connected CPs / CMs","Number of process alarm OBs":"50","Reverse polarity protection":"Yes","S7 communication, as client":"Yes","S7 communication, as server":"Yes","Vertical Installation, Max.":"40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off","Vertical Installation, Min.":"-40 °C; = Tmin; Startup @ -20 °C","SIMATIC memory card required":"Yes","Connection display LINK TX/RX":"Yes","Horizontal Installation, Max.":"70 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off","Horizontal Installation, Min.":"-40 °C; = Tmin; Startup @ -20 °C","Number of PROFINET interfaces":"1","Number of configurable Traces":"4; Up to 512 KB of data per trace are possible","Industrial Ethernet status LED":"Yes","Number of cyclic interrupt OBs":"20","Number of diagnostic alarm OBs":"1","Number of isochronous mode OBs":"1","Number of synchronous error OBs":"2","Of Which Status Variables, Max.":"200; per job","For Fixed Point Arithmetic, Typ.":"64 ns","Number of asynchronous error OBs":"4","Number of distributed IO systems":"7","Number of positioning axes, max.":"6; Max. number of positioning axes (requirement: there must be no other motion technology objects created)","Of Which Control Variables, Max.":"200; per job","Current consumption (rated value)":"0.7 A","Infeed power to the backplane bus":"10 W","Number of external encoders, max.":"6; Max. number of external encoders (requirement: there must be no other motion technology objects created)","Number of subprocess images, max.":"32","Of which IO devices with IRT, max.":"64","Protection level: Write protection":"Yes","For Floating Point Arithmetic, Typ.":"256 ns","Joint commission (Team Engineering)":"Yes; Parallel online access possible for up to 3 engineering systems","Number of IO Devices per tool, max.":"8","Plug-in (SIMATIC Memory Card), max.":"32 Gbyte","Switchover time on line break, typ.":"200 ms","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Number of stations in the ring, max.":"50","Number of speed-controlled axes, max.":"6; Max. number of speed-controlled axes (requirement: there must be no other motion technology objects created)","Protection level: Complete protection":"Yes","Number of connectable IO Devices, max.":"128; In total, up to 256 distributed I/O devices can be connected via PROFIBUS or PROFINET","Number of alarms for system diagnostics":"100","Protection level: Read/write protection":"Yes","Mains/voltage failure stored energy time":"5 ms","Number of technology synchronous alarm OBs":"2","User program protection/password protection":"Yes","Number of configurable program messages, max.":"5 000","Number of connectable IO Devices for RT, max.":"128","Number of connections reserved for ES/HMI/web":"10","Number of alarms for motion technology objects":"160","Number of connections via integrated interfaces":"88","Several Passive Connections Per Port, Supported":"Yes","Number of IO Controllers with shared device, max.":"4","With IRT and parameterization of \"odd\" send cycles":"Update time = set \"odd\" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)","Power consumption from the backplane bus (balanced)":"5.5 W","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Number of login stations for message functions, max.":"32","STEP 7 TIA Portal configurable/integrated as of version":"V13 Update 3","Retentive data area (incl. timers, counters, flags), max.":"128 kbyte; In total; available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB","Isochronous operation (application synchronized up to terminal)":"Yes","Number of IO Devices that can be simultaneously activated/deactivated, max.":"8"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2ed26864a4538689e263fb80d426fcbf.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=130264&mlfb=6AG1513-1AL00-7AB0"},"ai":{"faq":[{"question":"What is the difference between 6AG1513-1AL00-7AB0 and 6AG1513-1AL01-7AB0?","answer":"The 6AG1513-1AL01-7AB0 is a later firmware revision. Both share identical core specifications: PROFINET IRT, MRP, web server, 32 kbyte I/O process image, and same programming languages. The AL01 can be used as a direct functional substitute; the AL00 remains available via RFQ."},{"question":"Does this CPU support DCP and FBD?","answer":"Yes. DCP (Discovery and Configuration Protocol) is supported for PROFINET device naming. FBD (Function Block Diagram) is one of the available programming languages."},{"question":"What is the I²t rating for the 6AG1513-1AL00-7AB0?","answer":"The onboard power supply has a rated I²t of 0.02 A²·s."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1513-1AL00-7AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1513-1AL00-7AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}