{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1513-1AL01-2AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1513-1AL01-2AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1513-1AL01-2AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1513-1AL01-2AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens S7-1500 SIPLUS CPU 6AG1513-1AL01-2AB0, -40 to 70°C, MRP redundancy manager, web server with HTTPS.","salesMarkdown":"## Field-fit for cold and hot environments That means it's the version you specify for freezer lines, desert switchgear, or anywhere the panel sees thermal extremes. Below 0 °C the display legibility drops, but the logic and I/O remain functional; plan remote monitoring if the panel is subzero during operation. Integrated MRP redundancy manager handles rings up to 50 devices without an extra module. Saves one slot and the associated wiring if you're building a redundant ring. Compatible with standard S7-1500 MRP clients. ## Built-in web server and communication stack HTTP and HTTPS web server with standard and user-defined pages — no additional license or HMI hardware for basic monitoring. HTTPS is factory-enabled, covering modern security policies. controller is integrated for valve applications, with auto-tuning available in STEP 7 V12 SP1 and later. Supports MODBUS TCP, TCP/IP, UDP, and SNMP. No DHCP on this unit — set a fixed IP or assign via the controller program. PROFINET IO with IRT is supported, and S7 routing allows cross-network programming. ## Sourcing reality: genuine part, different passport This order code is the extended-temperature variant, often stocked in European or APAC distribution. Same part, different passport — it's genuine Siemens, but may carry regional packaging and a local warranty that doesn't always transfer out of region. Let me be transparent: if your plant requires an official Siemens service contract, the standard-temperature sibling may be a cleaner path. But for cold-environment builds, this is the correct spec.","metaTitle":"Siemens 6AG1513-1AL01-2AB0 CPU, -40 to 70°C, MRP","metaDescription":"Siemens 6AG1513-1AL01-2AB0 S7-1500 CPU with extended temperature -40 to 70°C, MRP redundancy manager, web server, PID_3Step. Genuine cross-border stock sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"DCP":"Yes","FBD":"Yes","I2t":"0.34 A²·s","IRT":"Yes","LAD":"Yes","MRP":"Yes; as MRP redundancy manager and/or MRP client; max. number of devices in the ring: 50","SCL":"Yes","STL":"Yes","UDP":"Yes","DHCP":"No","HTTP":"Yes; Standard and user-defined pages","LLDP":"Yes","Max.":"70 °C","Min.":"-40 °C","SNMP":"Yes","Type":"Hardware clock","Depth":"129 mm","GRAPH":"Yes; As of STEP 7 V12 SP1","HTTPS":"Yes; Standard and user-defined pages","Note:":"At temperatures below 0 °C legibility may be restricted and representation of dynamic contents may be slower","Width":"35 mm","title":"6AG1513-1AL01-2AB0","Height":"147 mm","Inputs":"32 kbyte; All inputs are in the process image","MODBUS":"Yes; MODBUS TCP","Number":"Any (only limited by the main memory)","TCP/IP":"Yes","Via CM":"6; A maximum of 6 CMs (PROFINET + PROFIBUS) can be inserted in total","Outputs":"32 kbyte; All outputs are in the process image","Present":"Yes","100 Mbps":"Yes","ERROR LED":"Yes","MAINT LED":"Yes","PID_3Step":"Yes; PID controller with integrated optimization for valves","Supported":"Yes","Variables":"Inputs, outputs, memory bits, DB, times, counters","Adjustable":"Yes","Integrated":"1","S7 routing":"Yes","Size, max.":"16 kbyte","Web server":"Yes","Backup time":"6 wk; At 40 °C ambient temperature, typically","Lower Limit":"adjustable minimum cycle time","PID_Compact":"Yes; Universal PID controller with integrated optimization","PROFIenergy":"Yes","Single step":"No","Upper Limit":"adjustable maximum cycle time","description":"***spare part*** SIPLUS S7-1500 CPU 1513-1 PN -40...+60 °C start up -20 °C with conformal coating based on 6ES7513-1AL01-0AB0. central processing unit with work memory 300 KB for program and 1.5 MB for data, 1st interface: PROFINET IRT with 2-port switch, 40 ns bit performance, SIMATIC memory card required spare part display: 6AG1591-1AA01-2AA0","Autocrossing":"Yes","Equidistance":"Yes","Number, max.":"1 999; Number range: 1 to 65535","RUN/STOP LED":"Yes","Status block":"Yes; Up to 16 simultaneously","in AS, slave":"Yes","in AS, master":"Yes","Motion Control":"Yes","Number of keys":"6","Program alarms":"Yes","Updating times":"The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data","Autonegotiation":"Yes","Copy protection":"Yes","Inputs (volume)":"8 kbyte","Number of ports":"2","Weight, approx.":"430 g","lifecycle_stage":"current","Block protection":"Yes","Isochronous mode":"Yes","Maintenance-Free":"Yes","Media redundancy":"Yes","Outputs (volume)":"8 kbyte","Power loss, typ.":"5.7 W","RJ 45 (Ethernet)":"Yes","Data length, max.":"1 472 byte","Integrated Switch":"Yes","Number of PtP CMs":"the number of connectable PtP CMs is only limited by the number of available slots","Forcing, variables":"Inputs, outputs","High-speed counter":"Yes","PROFINET IO Device":"Yes","Per Priority Class":"24","Retentivity preset":"No","PG/OP communication":"Yes","Prioritized startup":"Yes; Max. 32 PROFINET devices","on Ethernet via NTP":"Yes","ISO-on-TCP (RFC1006)":"Yes","Inrush current, max.":"1.9 A; Rated value","Mode selector switch":"1","Number of IO modules":"2 048","Password for display":"Yes","Screen diagonal [cm]":"3.45 cm","Integrated (For Data)":"1.5 Mbyte","Number of lines, max.":"1","Number of startup OBs":"100","Open IE communication":"Yes","SIMATIC communication":"Yes","For Send Cycle Of 1 Ms":"1 ms to 512 ms","For Send Cycle Of 2 Ms":"2 ms to 512 ms","For Send Cycle Of 4 Ms":"4 ms to 512 ms","Modules per rack, max.":"32; CPU + 31 modules","Of Which In Line, Max.":"128","PROFINET IO Controller":"Yes","Retentivity adjustable":"Yes","Type of supply voltage":"24 V DC","Deviation per day, max.":"10 s; Typ.: 2 s","Status/control variable":"Yes","User data per job, max.":"BSEND/BRCV: 64 KB; PUT/GET: 960 bytes","For Bit Operations, Typ.":"40 ns","Integrated (For Program)":"300 kbyte","Number of DPV1 alarm OBs":"3","Number of blocks (total)":"2 000","Number of clock memories":"8; 8 clock memory bit, grouped into one clock memory byte","Number of free cycle OBs":"100","Number of time alarm OBs":"20","Of Which Powerfail-Proof":"250","Per Priority Class, Max.":"64 kbyte; max. 16 KB per block","For Send Cycle Of 250 μS":"250 µs to 128 ms","For Send Cycle Of 500 μS":"500 µs to 256 ms","For Word Operations, Typ.":"48 ns","Number of delay alarm OBs":"20","Number of variables, max.":"1 000","Number of connections, max.":"128","Number of process alarm OBs":"50","S7 communication, as client":"Yes","S7 communication, as server":"Yes","Vertical Installation, Max.":"40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off","Vertical Installation, Min.":"-40 °C; = Tmin; Startup @ -20 °C","SIMATIC memory card required":"Yes","Connection display LINK TX/RX":"Yes","Horizontal Installation, Max.":"60 °C; Display: 50 °C, at an operating temperature of typically 50 °C, the display is switched off","Horizontal Installation, Min.":"-40 °C; = Tmin; Startup @ -20 °C","Number of PROFINET interfaces":"1","Industrial Ethernet status LED":"Yes","Number of cyclic interrupt OBs":"20","Number of diagnostic alarm OBs":"1","Number of isochronous mode OBs":"1","Number of synchronous error OBs":"2","Of Which Status Variables, Max.":"200","For Fixed Point Arithmetic, Typ.":"64 ns","Number of asynchronous error OBs":"4","Number of distributed IO systems":"7","Number of positioning axes, max.":"6; Up to 6 axes in total (speed-controlled, positioning axis, external encoders) are supported","Of Which Control Variables, Max.":"200","Current consumption (rated value)":"0.7 A","Infeed power to the backplane bus":"10 W","Number of external encoders, max.":"6; Up to 6 axes in total (speed-controlled, positioning axis, external encoders) are supported","Number of subprocess images, max.":"32","Of which IO devices with IRT, max.":"64","Protection level: Write protection":"Yes","For Floating Point Arithmetic, Typ.":"256 ns","Number of IO Devices per tool, max.":"8","Plug-in (SIMATIC Memory Card), max.":"2 Gbyte","Switchover time on line break, typ.":"200 ms","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Number of stations in the ring, max.":"50","Number of speed-controlled axes, max.":"6; Up to 6 axes in total (speed-controlled, positioning axis, external encoders) are supported","Protection level: Complete protection":"Yes","Number of connectable IO Devices, max.":"128; In total, up to 256 distributed I/O devices can be connected via CPs/CMs via PROFIBUS or PROFINET.","Protection level: Read/write protection":"Yes","Number of technology synchronous alarm OBs":"2","Installation altitude above sea level, max.":"5 000 m","User program protection/password protection":"Yes","Number of configurable program messages, max.":"5 000","Number of connectable IO Devices for RT, max.":"128","Number of connections reserved for ES/HMI/web":"10","Number of simultaneously active program alarms":"500","Number of connections via integrated interfaces":"88","With IRT and parameterization of \"odd\" send cycles":"Update time = set \"odd\" send clock (any multiple of 125 µs: 375 µs, 625 µs ... 3 875 µs)","Power consumption from the backplane bus (balanced)":"5.5 W","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Number of login stations for message functions, max.":"32","Retentive data area (incl. timers, counters, flags), max.":"128 kbyte; Available retentive memory for bit memories, timers, counters, DBs, and technology data (axes): 88 KB","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Number of IO Devices that can be simultaneously activated/deactivated, max.":"8","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2ed26864a4538689e263fb80d426fcbf.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=689862&mlfb=6AG1513-1AL01-2AB0"},"ai":{"faq":[{"question":"Does the 6AG1513-1AL01-2AB0 support DCP?","answer":"Yes, DCP (Discovery and Configuration Protocol) is supported, allowing integration into PROFINET networks using Siemens configuration tools."},{"question":"Does it support FBD (Function Block Diagram) programming?","answer":"Yes, FBD is supported, along with LAD, STL, SCL, and GRAPH (as of STEP 7 V12 SP1)."},{"question":"What is the operating temperature range?","answer":"The CPU is rated from -40 °C to 70 °C. Note that below 0 °C the display legibility may be reduced, but the device remains operational."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1513-1AL01-2AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1513-1AL01-2AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}