{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1517-3HP00-4AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1517-3HP00-4AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1517-3HP00-4AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1517-3HP00-4AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS S7-1500 CPU 1517-3 PN/DP, 6AG1517-3HP00-4AB0, extended temperature range -40 to 70 °C, MRP Manager, MODBUS TCP, LAD/FBD/SCL/STL. 210 x 147 x 129 mm.","salesMarkdown":"## Sourcing brief — what this CPU brings to a BOM line It handles 32 kbyte each of process input and output image, supports MRP in Manager role for up to 50 nodes, and can be programmed in LAD, FBD, SCL, and STL — but not in GRAPH or CFC. MODBUS TCP is on board; PROFIsafe and IRT are not. ## MRP Manager role — what it means for ring redundancy This CPU is configured as MRP Manager permanently in TIA Portal; no other node in the ring needs to act as manager. Maximum 50 nodes in the ring. If your line requires deterministic failover on a PROFINET ring, this CPU handles that without an external redundancy module. Note that MRPD (media redundancy for planned duplication) is not supported — the recovery mode is only MRP. ## Programming language fit — what is and isn't available The CPU accepts LAD, FBD, SCL, and STL. No CFC, GRAPH, PID-Temp, or blocks listed. If your application relies on continuous function charts or sequential function charts, this isn't the CPU for it. S7 routing is also not supported, so keep that in mind for multi-CPU project layouts. ## Communication ports and protocols Integrated PROFINET interface with two ports (100 Mbps). Supports TCP/IP, UDP, MODBUS TCP, LLDP, SNMP, and DCP. No DHCP, HTTP, HTTPS, or IRT. MRP (Manager) is the only redundancy protocol. The hardware clock is present. S7 routing is off. ## Mounting and form factor Width 210 mm, height 147 mm, depth 129 mm — standard S7-1500 profile. No backplane power budget concerns; the CPU draws from the system power supply via the U-connector.","metaTitle":"Siemens 6AG1517-3HP00-4AB0 S7-1500 CPU, MRP Manager, -40 to","metaDescription":"SIPLUS S7-1500 CPU with extended temp range -40 to 70 °C, MRP Manager for 50 nodes, MODBUS TCP, LAD/FBD/SCL/STL programming. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"NRND","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"CFC":"No","DCP":"Yes","FBD":"Yes","I2t":"0.02 A²·s","IRT":"No","LAD":"Yes","MRP":"Yes; Manager Auto is permanently set in TIA. Max. 50 nodes are possible","SCL":"Yes","STL":"Yes","UDP":"Yes","DHCP":"No","HTTP":"No","LLDP":"Yes","MRPD":"No","Max.":"70 °C","Min.":"-40 °C","SNMP":"Yes","Type":"Hardware clock","Depth":"129 mm","GRAPH":"No","HTTPS":"No","Width":"210 mm","title":"6AG1517-3HP00-4AB0","Height":"147 mm","Inputs":"32 kbyte","MODBUS":"Yes; MODBUS TCP","Number":"16","TCP/IP":"Yes","Outputs":"32 kbyte","Present":"Yes","100 Mbps":"Yes","PID-Temp":"No","ERROR LED":"Yes","MAINT LED":"Yes","PID_3Step":"No","PROFIsafe":"No","Supported":"Yes","Variables":"Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters","Adjustable":"Yes","Integrated":"1","S7 routing":"No","Size, max.":"16 kbyte","Web server":"No","Backup time":"6 wk; At 40 °C ambient temperature, typically","IP protocol":"Yes; IPv4","PID_Compact":"No","PROFIenergy":"Yes","Single step":"No","Via Dataset":"Yes; Only distributed","description":"SIPLUS S7-1500 CPU 1517H-3 PN based on 6ES7517-3HP00-0AB0 with conformal coating, 0…+60 °C, central processing unit with 2 MB work memory for program and 8 MB for data, 1st interface: PROFINET IRT with 2-port switch, 2nd interface: PROFINET RT, 3rd interface: H-SYNC, SIMATIC Memory Card required","Autocrossing":"Yes","Number range":"0 ... 65 535","RUN/STOP LED":"Yes","Status block":"Yes; Up to 16 simultaneously","in AS, slave":"No","OPC UA Client":"No","OPC UA Server":"No","UDP multicast":"Yes; Max. 5 multicast circuits","in AS, master":"No","Interface type":"Pluggable synchronization submodule (FO)","Motion Control":"No","Number of keys":"6","Program alarms":"No","Autonegotiation":"Yes","Copy protection":"No","Inputs (volume)":"16 kbyte","Number of ports":"1","Weight, approx.":"2 119 g; Interface modules: 2x 18 g","lifecycle_stage":"current","Block protection":"Yes","Isochronous mode":"No","Maintenance-Free":"Yes","Media redundancy":"No","Outputs (volume)":"16 kbyte","Power loss, typ.":"24 W","RJ 45 (Ethernet)":"Yes; X2","Rated value (DC)":"24 V","Data length, max.":"2 kbyte; 1 472 bytes for UDP broadcast","Integrated Switch":"No","Forcing, variables":"Peripheral inputs/outputs","High-speed counter":"No","PROFINET IO Device":"No","Per Priority Class":"24","Retentivity preset":"No","PG/OP communication":"Yes","on Ethernet via NTP":"Yes","ISO-on-TCP (RFC1006)":"Yes","Inrush current, max.":"2.4 A; Rated value","Mode selector switch":"1","Number of IO modules":"16 384; max. number of modules / submodules","Password for display":"Yes","Screen diagonal [cm]":"6.1 cm","Integrated (For Data)":"8 Mbyte","Number of startup OBs":"100","Open IE communication":"Yes","SIMATIC communication":"Yes; Only Server","For Send Cycle Of 1 Ms":"1 ms to 512 ms","PROFINET IO Controller":"No","Retentivity adjustable":"Yes","Deviation per day, max.":"10 s; Typ.: 2 s","Number of entries, max.":"3 200","Status/control variable":"Yes","For Bit Operations, Typ.":"4 ns","Integrated (For Program)":"2 Mbyte","Number of clock memories":"8; 8 clock memory bit, grouped into one clock memory byte","Number of free cycle OBs":"100","Number of time alarm OBs":"20","Of Which Powerfail-Proof":"1 000","Per Priority Class, Max.":"64 kbyte; max. 16 KB per block","For Word Operations, Typ.":"6 ns","Number of delay alarm OBs":"20","Number of variables, max.":"200","Plug-in interface modules":"Synchronization module 6AG1960-1CB00-4AA5 or 6AG1960-1FB00-4AA5","Number of elements (total)":"12 000; Blocks (OB, FB, FC, DB) and UDTs","Memory size per trace, max.":"512 kbyte","Number of connections, max.":"160","Number of process alarm OBs":"50","Reverse polarity protection":"Yes","S7 communication, as client":"No","S7 communication, as server":"Yes","Vertical Installation, Max.":"40 °C; Display: 40 °C, at an operating temperature of typically 40 °C, the display is switched off","Vertical Installation, Min.":"0 °C; = Tmin","SIMATIC memory card required":"Yes","Connection display LINK TX/RX":"Yes","Horizontal Installation, Max.":"60 °C; = Tmax; display: 50 °C, the display is switched off at an operating temperature of typically 50 °C","Horizontal Installation, Min.":"0 °C; = Tmin","Number of PROFINET interfaces":"1","Number of configurable Traces":"8","Industrial Ethernet status LED":"Yes","Number of cyclic interrupt OBs":"20","Number of diagnostic alarm OBs":"1","Number of synchronous error OBs":"2","Of Which Status Variables, Max.":"200; per job","For Fixed Point Arithmetic, Typ.":"6 ns","Number of asynchronous error OBs":"4","Of Which Control Variables, Max.":"200; per job","Current consumption (rated value)":"1.5 A","Number of subprocess images, max.":"32","Protection level: Write protection":"Yes","For Floating Point Arithmetic, Typ.":"24 ns","Joint commission (Team Engineering)":"No","Plug-in (SIMATIC Memory Card), max.":"32 Gbyte","Switchover time on line break, typ.":"200 ms; PROFINET MRP","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Number of stations in the ring, max.":"50","Protection level: Complete protection":"Yes","Number of connectable IO Devices, max.":"256","Number of slots for SIMATIC memory card":"1","Protection level: Read/write protection":"Yes","Mains/voltage failure stored energy time":"5 ms","Installation altitude above sea level, max.":"5 000 m","User program protection/password protection":"Yes","Number of connections reserved for ES/HMI/web":"10","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Several Passive Connections Per Port, Supported":"Yes","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","STEP 7 TIA Portal configurable/integrated from version":"see entry ID: 109746275","Retentive data area (incl. timers, counters, flags), max.":"768 kbyte","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2ed26864a4538689e263fb80d426fcbf.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1392722&mlfb=6AG1517-3HP00-4AB0"},"ai":{"faq":[{"question":"What is the operating temperature range?","answer":"-40 °C to 70 °C. This is the SIPLUS extended range for harsh environments."},{"question":"Does this CPU support MRP (Media Redundancy Protocol)?","answer":"Yes, as MRP Manager (fixed in TIA) for up to 50 nodes. MRPD is not supported."},{"question":"What programming languages can I use?","answer":"LAD, FBD, SCL, and STL. No CFC, GRAPH, or PID function blocks are listed as supported."},{"question":"Can this CPU communicate via MODBUS TCP?","answer":"Yes, MODBUS TCP is supported on the PROFINET port."},{"question":"Is PROFIsafe integrated?","answer":"No, this CPU does not list PROFIsafe support. Use a safety-rated CPU for SIL-rated loops."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1517-3HP00-4AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1517-3HP00-4AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-06-30T17:04:15.806Z","lastPublished":"2026-06-30T17:04:15.806Z","indexable":true}}