{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1521-1BH00-7AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1521-1BH00-7AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1521-1BH00-7AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1521-1BH00-7AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens S7-1200 digital input module, 6AG1521-1BH00-7AB0, 16 inputs at 24 V DC, 35 mm width, active production.","salesMarkdown":"Siemens S7-1200 digital input module, 6AG1521-1BH00-7AB0, 16 inputs at 24 V DC, 35 mm width, active production.","metaTitle":"Siemens 6AG1521-1BH00-7AB0 S7-1200 16DI 24 VDC","metaDescription":"Active production Siemens 6AG1521-1BH00-7AB0 digital input module, 16 channels at 24 V DC, 35 mm width, 500 ms fast startup, diagnostics and isochronous mode.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Digital Input Modules"],"specifications":{"Depth":"129 mm","Width":"35 mm","title":"6AG1521-1BH00-7AB0","Height":"147 mm","RUN LED":"Yes; green LED","I&M data":"Yes; I&M0 to I&M3","ERROR LED":"Yes; red LED","Fuse blown":"No","Wire-break":"Yes; to I < 350 µA","description":"SIPLUS S7-1500 DI 16x24VDC HF based on 6ES7521-1BH00-0AB0 with conformal coating, -40…+70 °C, digital input module, 16 channels in groups of 16; input delay 0.05..20 ms input type 3 (IEC 61131); diagnostics; hardware interrupts","Fast startup":"Yes; 500 ms","2-Wire Sensor":"Yes","Short-circuit":"No","For Signal \"0\"":"-30 to +5 V","For Signal \"1\"":"+11 to +30V","Shielded, Max.":"1 000 m","Parameterizable":"Yes","Weight, approx.":"240 g","lifecycle_stage":"current","Diagnostic alarm":"Yes","Firmware version":"V1.0.0","Isochronous mode":"Yes","Power loss, typ.":"2.6 W","Rated value (DC)":"24 V","Unshielded, Max.":"600 m","Source/sink input":"P-reading","Hardware interrupt":"Yes","At \"0\" To \"1\", Max.":"20 ms","At \"0\" To \"1\", Min.":"0.05 ms","At \"1\" To \"0\", Max.":"20 ms","At \"1\" To \"0\", Min.":"0.05 ms","Between The Channels":"No","Diagnostics function":"Yes","For Signal \"1\", Typ.":"2.5 mA","HW functional status":"E01","Isolation tested with":"707 V DC (type test)","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; red LED","For Channel Diagnostics":"Yes; red LED","Number of digital inputs":"16","Current consumption, max.":"20 mA; with 24 V DC supply","Between Different Circuits":"75 V DC/60 V AC (base isolation)","Bus cycle time (TDP), min.":"250 µs","Reverse polarity protection":"Yes","Vertical Installation, Max.":"40 °C; = Tmax","Vertical Installation, Min.":"-40 °C; = Tmin","Horizontal Installation, Max.":"70 °C; = Tmax","Horizontal Installation, Min.":"-40 °C; = Tmin (incl. condensation/frost)","Monitoring the supply voltage":"Yes","Suitable for safety functions":"No","Between The Channels, In Groups Of":"16","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Between The Channels And Backplane Bus":"Yes","Power available from the backplane bus":"1.1 W","Filtering and processing time (TCI), min.":"80 µs; At 50 μs filter time","Monitoring of the supply voltage (PWR-LED)":"Yes; green LED","Installation altitude above sea level, max.":"5 000 m","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Permissible Quiescent Current (2-Wire Sensor), Max.":"1.5 mA","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","STEP 7 TIA Portal configurable/integrated from version":"V12 / V12","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Between The Channels And The Power Supply Of The Electronics":"No","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$251.46","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/f3a8ed982d443beab44494c5d6c7ebff.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=376118&mlfb=6AG1521-1BH00-7AB0"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1521-1BH00-7AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1521-1BH00-7AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}