{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1522-5HF00-2AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1522-5HF00-2AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1522-5HF00-2AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1522-5HF00-2AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS S7-1500 digital output module, 6AG1522-5HF00-2AB0, 8 relay outputs, 24 VDC, 5 A per channel, MSO Yes, depth 129 mm.","salesMarkdown":"The Siemens 6AG1522-5HF00-2AB0 is a SIPLUS S7-1500 digital output module with 8 relay outputs, each rated for a signal '1' of 5 A at 24 VDC. Rated supply voltage 24 VDC, typical power loss 3 W. MSO support is enabled (Yes) for time-synchronous line applications – the module can participate in clocked I/O updates alongside other MSO-capable S7-1500 modules. Depth of 129 mm matches the standard S7-1500 mounting depth, so it fits existing panel layouts without clearance changes. ## Compared to the standard S7-1500 variant 6ES7522-5HF00-0AB0 The SIPLUS variant 6AG1522-5HF00-2AB0 shares the same electrical specification and pinout as the standard 6ES7522-5HF00-0AB0 – same 8 relay outputs, same 5 A rating, same 24 V supply, same MSO capability, same depth and width. The difference lies in environmental resilience: SIPLUS modules are built for extended temperature ranges, humidity, and corrosive atmospheres, typically with conformal coating. For a panel builder or MRO planner, this means the SIPLUS version is a drop-in replacement for the standard module when the ambient conditions exceed the standard range; there is no wiring or addressing change. If the environment is already controlled (e.g. IP54 cabinet with HVAC), the standard module may suffice. For new designs in harsh plants, specify the SIPLUS variant at the start. Mounting: 35 mm wide, snap-on DIN rail; depth 129 mm. Channel isolation tested at 2 500 V DC; no internal short-circuit protection (fuse each group per manual; max 8 A per group, 64 A per module). Diagnostic alarm and module diagnostics supported; wire-break diagnostics not available.","metaTitle":"Siemens SIPLUS 6AG1522-5HF00-2AB0 Digital Output, 8 Relay, 2","metaDescription":"SIPLUS S7-1500 digital output module – 8 relay channels, 5 A per channel, 24 VDC, MSO Yes, depth 129 mm. Current production; sourced to order. RFQ for stock.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Digital Output Modules"],"specifications":{"MSO":"Yes","Depth":"129 mm","Width":"35 mm","title":"6AG1522-5HF00-2AB0","Height":"147 mm","RUN LED":"Yes; green LED","I&M data":"Yes; I&M0 to I&M3","ERROR LED":"Yes; red LED","Wire-break":"No","description":"SIPLUS S7-1500 DQ 8x230V AC/5A based on 6ES7522-5HF00-0AB0 with conformal coating, -25…+60 °C, digital output module, 8 channels in groups of 1; 5 A per group; diagnostics; substitute value","Fast startup":"Yes; 500 ms","For Uprating":"No","Short-circuit":"No","Shielded, Max.":"1 000 m","For Logic Links":"Yes","Weight, approx.":"200 g","lifecycle_stage":"current","Diagnostic alarm":"Yes","Isochronous mode":"No","Power loss, typ.":"3 W","Rated value (DC)":"24 V","Unshielded, Max.":"600 m","On Lamp Load, Max.":"2 Hz","Between The Channels":"Yes; Switching of different phases permitted","Diagnostics function":"Yes","Isolation tested with":"Between the channels: 2 500 V DC; between the channels and backplane bus: 2 500 V DC; between L+ backplane bus 707 V DC (type test)","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; red LED","Type of digital output":"Relays","Current per group, max.":"8 A; note derating data in the manual","For Channel Diagnostics":"No","Number of relay outputs":"8","Current per module, max.":"64 A; note derating data in the manual","Short-circuit protection":"No","Current consumption, max.":"80 mA","Current per channel, max.":"8 A; note derating data in the manual","Number of digital outputs":"8","With Inductive Load, Max.":"see additional description in the manual","With Resistive Load, Max.":"see additional description in the manual","Between Different Circuits":"75 V DC/60 V AC (base isolation) between backplane bus and the supply voltage L+; 250 V AC between the channels and the supply voltage L+; 250 V AC between the channels and the backplane bus; 500 V AC between the channels","For Signal \"1\" Rated Value":"5 A","Controlling a digital input":"possible","Vertical Installation, Max.":"40 °C; = Tmax","Vertical Installation, Min.":"-25 °C; = Tmin","Contact connection (internal)":"No","Horizontal Installation, Max.":"60 °C; = Tmax","Horizontal Installation, Min.":"-25 °C; = Tmin (incl. condensation/frost)","Monitoring the supply voltage":"Yes","Relay approved acc. to UL 508":"Yes; 250 V AC/5 A g.p.; 120 V AC TV-4 tungsten; A300, R300","Substitute values connectable":"Yes","Suitable for safety functions":"No","For Redundant Control Of A Load":"Yes","Digital outputs, parameterizable":"Yes","Fluorescent tubes, uncompensated":"10x 58 W (25 000 operating cycles)","Number of operating cycles, max.":"4 000 000; see additional description in the manual","Between The Channels, In Groups Of":"1","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","External Protection For Relay Outputs":"With miniature circuit breaker with characteristic B for: cos φ 1.0: 600 A cos φ 0.5 ... 0.7: 900 A with 8 A Diazed fuse: 1 000 A","For Signal \"0\" Residual Current, Max.":"0 A","Between The Channels And Backplane Bus":"Yes","For Signal \"1\" Permissible Range, Max.":"8 A; thermal continuous current","For Signal \"1\" Permissible Range, Min.":"5 mA; 10 V","Power available from the backplane bus":"0.8 W","Between the channels and load voltage L+":"Yes","Monitoring of the supply voltage (PWR-LED)":"Yes; green LED","Rated supply voltage of relay coil L+ (DC)":"24 V","Installation altitude above sea level, max.":"2 000 m","Fluorescent tubes, conventionally compensated":"1x 58 W (25 000 operating cycles)","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Size of motor starters according to NEMA, max.":"5","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m)","Low energy/fluorescent lamps with electronic control gear":"10x 58 W (25 000 operating cycles)","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Current consumption of relays (coil current of all relays), max.":"80 mA","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2f71d94b2617ca09e00273b1b7ec284f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=157496&mlfb=6AG1522-5HF00-2AB0"},"ai":{"faq":[{"question":"What is the closest functional alternate — 6ES7522-5HF00-0AB0?","answer":"The standard S7-1500 module 6ES7522-5HF00-0AB0 is the form-fit-function equivalent. Both share the same electrical ratings, MSO support, dimensions, and pinout. The SIPLUS variant adds environmental hardening (extended temperature, coating) for harsh conditions. Either can be specified in a panel designed for the other without rewiring."},{"question":"What is the listed depth of 6AG1522-5HF00-2AB0?","answer":"Depth is 129 mm, matching the standard S7-1500 module depth. It fits into the same cabinet space as other S7-1500 I/O modules."},{"question":"Will 6AG1522-5HF00-2AB0 drop into a panel specified for 6ES7522-5HF00-0AB0?","answer":"Yes, the two modules are dimensionally identical and pin-compatible. No change to backplane addressing, wiring, or configuration is required. The SIPLUS variant is a direct, ruggedized substitute."},{"question":"What does MSO = Yes mean for this module?","answer":"MSO (Mixed Signal Operation) support allows the module to participate in time-synchronous (clocked) communication with other MSO-capable S7-1500 modules on the same backplane. This is relevant for applications requiring deterministic I/O updates, such as high-speed motion coordination."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1522-5HF00-2AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1522-5HF00-2AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}