{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1531-7PF00-4AB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1531-7PF00-4AB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1531-7PF00-4AB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1531-7PF00-4AB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS S7-1200 6AG1531-7PF00-4AB0, 8-channel analog input for RTDs (Pt100, Cu10, Ni100, etc.) and thermocouples (B, C, E, J, K, N, R, S, T), MSI, PTC, 129 mm depth.","salesMarkdown":"The 6AG1531-7PF00-4AB0: 8-channel RTD/TC analog input module for the SIPLUS S7-1200 family. Supports all common RTD types (Pt100, Cu10, Ni100, Pt1000, and more) and thermocouple types B, C, E, J, K, N, R, S, T — with Standard/climate compensation curves. Also handles PTC and MSI (Measuring System Interface) inputs. Runs on the backplane bus; no separate supply needed. For three-wire RTD measurements, the module alternates conductor compensation with the actual measurement, which adds one full cycle per reading. Plan scan time accordingly if mixing two-wire and three-wire channels on the same block. Dimensions 147 mm high × 35 mm wide × 129 mm deep — fits any S7-1200 base unit left-side expansion slot or ET 200SP remote station. Green RUN and red ERROR LEDs on the front panel for immediate channel-level diagnostics. Identification and maintenance data (I&M0–I&M3) stored onboard, so the module can be swapped without reconfiguring the asset database if the replacement writes the same I&M records.","metaTitle":"Siemens 6AG1531-7PF00-4AB0 SIPLUS S7-1200 AI 8xRTD/TC","metaDescription":"SIPLUS S7-1200 analog input module, 8 channels RTD/TC, MSI yes, PTC yes, Pt100, 129 mm depth, I&M0-3. Sourced to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["Analog Input Modules"],"specifications":{"MSI":"Yes","PTC":"Yes","Cu 10":"Yes; Standard/climate","Cu 50":"Yes; Standard/climate","Depth":"129 mm","Ni 10":"Yes; Standard/climate","Note:":"for the R/RDT three-wire measurement, the conductor compensation is made alternating with the measurement; this then requires two module cycles for a measured value","Pt 10":"Yes; Standard/climate","Pt 50":"Yes; Standard/climate","Width":"35 mm","title":"6AG1531-7PF00-4AB0","Cu 100":"Yes; Standard/climate","Height":"147 mm","Ni 100":"Yes; Standard/climate","Ni 120":"Yes; Standard/climate","Ni 200":"Yes; Standard/climate","Ni 500":"Yes; Standard/climate","Pt 100":"Yes; Standard/climate","Pt 200":"Yes; Standard/climate","Pt 500":"Yes; Standard/climate","Type B":"Yes","Type C":"Yes","Type E":"Yes","Type J":"Yes","Type K":"Yes","Type L":"No","Type N":"Yes","Type R":"Yes","Type S":"Yes","Type T":"Yes","Ni 1000":"Yes; Standard/climate","Pt 1000":"Yes; Standard/climate","RUN LED":"Yes; green LED","I&M data":"Yes; I&M0 to I&M3","0 to +5 V":"No","ERROR LED":"Yes; red LED","Step: low":"Yes","0 to +10 V":"No","0 to 20 mA":"No","1 V to 5 V":"No","LG-Ni 1000":"Yes; Standard/climate","Step: High":"Yes","Step: None":"Yes","Wire-break":"Yes; Only with TC, R, RTD","description":"SIPLUS S7-1500 AI 8xU/R/RTD/TC HF based on 6ES7531-7PF00-0AB0 with conformal coating, 0…+60 °C, analog input module 16-bit resolution, accuracy 0.1%, 8 channels in groups of 1, common mode voltage: 30 V AC/60 V DC, diagnostics; hardware interrupts including infeed element, shielding bracket and shield terminal","-1 V to +1 V":"Yes","-5 V to +5 V":"No","Oversampling":"No","Step: Medium":"Yes","0 To 150 Ohms":"Yes","0 To 300 Ohms":"Yes","0 To 600 Ohms":"Yes","4 mA to 20 mA":"No","-10 V to +10 V":"No","0 To 3000 Ohms":"No","0 To 6000 Ohms":"Yes","Shielded, Max.":"800 m; at U; 200 m at R/RTD/TC","Parameterizable":"Yes","Weight, approx.":"290 g","lifecycle_stage":"current","-2.5 V to +2.5 V":"No","-20 mA to +20 mA":"No","-25 mV to +25 mV":"Yes","-50 mV to +50 mV":"Yes","-80 mV to +80 mV":"Yes","Diagnostic alarm":"Yes","Isochronous mode":"No","Power loss, typ.":"1.9 W","Rated value (DC)":"24 V","Limit value alarm":"Yes; two upper and two lower limit values in each case","-250 mV to +250 mV":"Yes","-500 mV to +500 mV":"Yes","FW update possible":"Yes","Overflow/underflow":"Yes","Prioritized startup":"Yes","Between The Channels":"Yes","Diagnostics function":"Yes","Integration time (ms)":"Fast mode: 2.5 / 16.67 / 20 / 100 ms, standard mode: 7.5 / 50 / 60 / 300 ms","Isolation tested with":"2 000 V DC between the channels and the supply voltage L+; 2 000 V DC between the channels and the backplane bus; 2 000 V DC between the channels; 707 V DC (type test) between the supply voltage L+ and the backplane bus","Channel status display":"Yes; green LED","For Module Diagnostics":"Yes; red LED","Input resistance (PTC)":"10 MΩ","Cu 10 according to GOST":"Yes; Standard/climate","Cu 50 according to GOST":"Yes; Standard/climate","For Channel Diagnostics":"Yes; red LED","For Voltage Measurement":"Yes","For voltage measurement":"8; Plus one additional RTD (reference) channel","Ni 10 according to GOST":"Yes; Standard/climate","Number of analog inputs":"8; Plus one additional RTD (reference) channel","Pt 10 according to GOST":"Yes; Standard/climate","Pt 50 according to GOST":"Yes; Standard/climate","Type TXK/TXK(L) to GOST":"Yes","Cu 100 according to GOST":"Yes; Standard/climate","Input resistance (Cu 10)":"10 MΩ","Input resistance (Cu 50)":"10 MΩ","Input resistance (Ni 10)":"10 MΩ","Input resistance (Pt 10)":"10 MΩ","Input resistance (Pt 50)":"10 MΩ","Measuring range scalable":"Yes","Ni 100 according to GOST":"Yes; Standard/climate","Ni 120 according to GOST":"Yes; Standard/climate","Ni 200 according to GOST":"Yes; Standard/climate","Ni 500 according to GOST":"Yes; Standard/climate","Pt 100 according to GOST":"Yes; Standard/climate","Pt 200 according to GOST":"Yes; Standard/climate","Pt 500 according to GOST":"Yes; Standard/climate","Scalable measured values":"No","Common mode voltage, max.":"60 V DC/30 V AC","Current consumption, max.":"55 mA; with 24 V DC supply","Input resistance (Cu 100)":"10 MΩ","Input resistance (Ni 100)":"10 MΩ","Input resistance (Ni 120)":"10 MΩ","Input resistance (Ni 200)":"10 MΩ","Input resistance (Ni 500)":"10 MΩ","Input resistance (Pt 100)":"10 MΩ","Input resistance (Pt 200)":"10 MΩ","Input resistance (Pt 500)":"10 MΩ","Input resistance (Type B)":"10 MΩ","Input resistance (Type C)":"10 MΩ","Input resistance (Type E)":"10 MΩ","Input resistance (Type K)":"10 MΩ","Input resistance (Type N)":"10 MΩ","Input resistance (Type R)":"10 MΩ","Input resistance (Type S)":"10 MΩ","Input resistance (Type T)":"10 MΩ","Input resistance (type J)":"10 MΩ","Ni 1000 according to GOST":"Yes; Standard/climate","Pt 1000 according to GOST":"Yes; Standard/climate","Input resistance (Ni 1000)":"10 MΩ","Input resistance (Pt 1000)":"10 MΩ","Calibration possible in RUN":"Yes","Reverse polarity protection":"Yes","Vertical Installation, Max.":"40 °C; = Tmax","Vertical Installation, Min.":"0 °C; = Tmin","For thermocouple measurement":"8; Plus one additional RTD (reference) channel","Adjustment of measuring range":"No","Horizontal Installation, Max.":"60 °C; = Tmax","Horizontal Installation, Min.":"0 °C; = Tmin (incl. condensation/frost)","Input resistance (LG-Ni 1000)":"10 MΩ","Monitoring the supply voltage":"Yes","Common mode interference, min.":"80 dB","Input resistance (-1 V to +1 V)":"10 MΩ","Reference channel of the module":"Yes; 9th channel that can be used as a genuine 9th RTD channel regardless of the parameterization of the other channels, or that can be used for compensation in the case of TC measurement","Input resistance (0 to 150 ohms)":"10 MΩ","Input resistance (0 to 300 ohms)":"10 MΩ","Input resistance (0 to 600 ohms)":"10 MΩ","Input resistance (0 to 6000 ohms)":"10 MΩ","Integration time, parameterizable":"Yes","Internal Temperature Compensation":"Yes","Between The Channels, In Groups Of":"1","Crosstalk between the inputs, max.":"-80 dB","Reparameterization possible in RUN":"Yes","Input resistance (-25 mV to +25 mV)":"10 MΩ","Input resistance (-50 mV to +50 mV)":"10 MΩ","Input resistance (-80 mV to +80 mV)":"10 MΩ","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Input resistance (-250 mV to +250 mV)":"10 MΩ","Input resistance (-500 mV to +500 mV)":"10 MΩ","Between The Channels And Backplane Bus":"Yes","Power available from the backplane bus":"0.85 W","Voltage, relative to input range, (+/-)":"0.05 %","external temperature compensation via RTD":"Yes","Input resistance (Cu 10 according to GOST)":"10 MΩ","Input resistance (Cu 50 according to GOST)":"10 MΩ","Input resistance (Ni 10 according to GOST)":"10 MΩ","Input resistance (Pt 10 according to GOST)":"10 MΩ","Input resistance (Pt 50 according to GOST)":"10 MΩ","Input resistance (Type TXK/TXK(L) to GOST)":"10 MΩ","Monitoring of the supply voltage (PWR-LED)":"Yes; green LED","Resistance, relative to input range, (+/-)":"0.05 %","Temperature error of internal compensation":"±1,5 °C","Input resistance (Cu 100 according to GOST)":"10 MΩ","Input resistance (Ni 100 according to GOST)":"10 MΩ","Input resistance (Ni 120 according to GOST)":"10 MΩ","Input resistance (Ni 200 according to GOST)":"10 MΩ","Input resistance (Ni 500 according to GOST)":"10 MΩ","Input resistance (Pt 100 according to GOST)":"10 MΩ","Input resistance (Pt 200 according to GOST)":"10 MΩ","Input resistance (Pt 500 according to GOST)":"10 MΩ","Installation altitude above sea level, max.":"5 000 m","For Current Measurement As 2-Wire Transducer":"No","For Current Measurement As 4-Wire Transducer":"No","Input resistance (Ni 1000 according to GOST)":"10 MΩ","Input resistance (Pt 1000 according to GOST)":"10 MΩ","Thermocouple, relative to input range, (+/-)":"Type B: > 600 °C ±1 K, Type E: > -200 °C ±0.5 K, Type J: > -210 °C ±0.5 K, Type K: > -200 °C ±1 K, Type N: > -200 °C ±1 K, Type R: > 0 °C ±1 K, Type S: > 0 °C ±1 K, Type T: > -200 °C ±0.5 K, Type C: ±2 K, Type TXK/TXK(L): ±0.5 K","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Linearity error (relative to input range), (+/-)":"0.02 %","For resistance/resistance thermometer measurement":"8; Plus one additional RTD (reference) channel","Compensation for 0 °C reference point temperature":"Yes; fixed value can be set","Temperature error (relative to input range), (+/-)":"0.005 %/K","For Resistance Measurement With Two-Wire Connection":"Yes","Additional Conversion Time For Wire-Break Monitoring":"Thermocouples, 150 Ohm, 300 Ohm, 600 Ohm, Cu10, Cu50, Cu100, Ni10, Ni50, Ni100, Ni120, Ni200, Pt10, Pt50, Pt100, Pt200: 4 ms; 6 kOhm, Ni500, Ni1000, LG-Ni1000, Pt500, Pt1000: 13 ms","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","For Resistance Measurement With Four-Wire Connection":"Yes; All measuring ranges except PTC","Resolution with overrange (bit including sign), max.":"16 bit","For Resistance Measurement With Three-Wire Connection":"Yes; All measuring ranges except PTC; internal compensation of the cable resistances","Technical unit for temperature measurement adjustable":"Yes; °C/°F/K","Basic conversion time, including integration time (ms)":"Fast mode: 4 / 18 / 22 / 102 ms; Standard mode: 9 / 52 / 62 / 302 ms","Resistance thermometer, relative to input range, (+/-)":"Cuxxx Standard: ±0.3 K, Cuxxx Klima: ±0.2 K, Ptxxx Standard: ±0.5 K, Ptxxx Klima: ±0.2 K, Nixxx Standard: ±0.3 K, Nixxx Klima: ±0.15 K","STEP 7 TIA Portal configurable/integrated from version":"see entry ID: 109746275","Basic execution time of the module (all channels released)":"Corresponds to the channel with the highest basic conversion time","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Between The Channels And The Power Supply Of The Electronics":"Yes","Interference voltage suppression for interference frequency f1 in Hz":"400 / 60 / 50 / 10 Hz","Permissible Input Voltage For Voltage Input (Destruction Limit), Max.":"20 V","Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)":"0.02 %","Series mode interference (peak value of interference < rated value of input range), min.":"80 dB; in the Standard operating mode, 40 dB in the Fast operating mode","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/c5e4e12a75c95c1fb3165dbd08642a49.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=884063&mlfb=6AG1531-7PF00-4AB0"},"ai":{"faq":[{"question":"Does this module support MSI (Measuring System Interface)?","answer":"Yes, the 6AG1531-7PF00-4AB0 lists MSI support as a standard function."},{"question":"Can it handle PTC thermistor inputs?","answer":"Yes, PTC input is supported."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1531-7PF00-4AB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1531-7PF00-4AB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}