{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1593-0AB00-7AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1593-0AB00-7AA0","canonicalUrl":"https://aoctrl.com/siemens/6AG1593-0AB00-7AA0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1593-0AB00-7AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIPLUS S7-1500 cooling fan, 210 mm, 24 VDC, -40 to 70°C, conformal coated,","salesMarkdown":"## Field-replaceable cooling fan for SIPLUS S7-1500 The Siemens 6AG1593-0AB00-7AA0 is a SIPLUS S7-1500 cooling fan, 210 mm wide, designed to bolt onto the CPU 1517H-3 (6AG1517-3HP00-4AB0) and CPU 1518HF (6AG1518-4JP00-4AB0). It is the field-replaceable fan unit—no need to swap the whole controller if the fan seizes. Red LED warning indicator switches on at standstill or low fan speed, so you catch a stall before the CPU cooks. If your panel lives in a harsh environment, this is the right fan. ## What you need to know for installation Powered from 24 VDC (19.2–27.7 V range), drawing 0.07 A max with a 0.17 A inrush. Push-in terminals with end sleeves; strip to 10 mm. Dimensions are 210 x 119 x 54 mm (WxDxH), IP20. Sits on the front of the CPU, so no extra DIN rail space needed. Conformal coating covers the PCB—handles the board with gloves if you're swapping in the field; no need to bag it from condensation. Power loss is typical 1.7 W. Not much heat to manage, but the fan itself moves air across the CPU heatsink. The digital output OK signal lets the controller know the fan is running—tie it into your diagnostics. Listed as current lifecycle stage—no end-of-life notice, no last-time-buy pressure. You can quote this into a BOM today and count on supply for the next few years. This is a genuine Siemens SIPLUS part, not a third-party substitute. It is rated for -40°C to 70°C.","metaTitle":"6AG1593-0AB00-7AA0 SIPLUS S7-1500 Fan, 70°C","metaDescription":"SIPLUS S7-1500 cooling fan, 24 VDC, -40 to 70°C, conformal coating. Red LED alarm. Active production. RFQ your line.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"Active","categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Max.":"70 °C","Min.":"-40 °C","Depth":"119 mm","Width":"210 mm","title":"6AG1593-0AB00-7AA0","Alarms":"Yes; red LED warning indicator switches on at standstill or low fan speed","Height":"54 mm","description":"SIPLUS S7-1500 cooling fan 210 mm with conformal coating 0...+70 °C suitable for the following CPUs: SIPLUS S7-1500 CPU 1517H-3 (6AG1517-3HP00-4AB0); SIPLUS S7-1500 CPU 1518HF (6AG1518-4JP00-4AB0)","For Uprating":"No","For Logic Links":"No","Weight, approx.":"235 g","lifecycle_stage":"current","Current-sourcing":"Yes","Power loss, typ.":"1.7 W","Rated value (DC)":"24 V","Unshielded, Max.":"3 m","Connection method":"Push-in terminal","Diagnostics function":"Yes; digital output OK","HW functional status":"01","Inrush current, max.":"0.17 A","IP degree of protection":"20","Tightening torque, max.":"0.3 N·m; screw interlock","Tightening torque, min.":"0.3 N·m; screw interlock","Current consumption, max.":"0.07 A","Controlling a digital input":"Yes; digital input according to IEC 61131, type 3","Reverse polarity protection":"Yes","Number of lines per connection":"1","For Redundant Control Of A Load":"No","Stripped length of cables, min.":"10 mm","Current consumption (rated value)":"0.05 A","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"27.7 V","Installation altitude above sea level, max.":"5 000 m","End sleeve acc. to DIN 46228 with plastic sleeve":"8 mm long","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","Connectable cable cross-sections for massive cables, min.":"16","Connectable cable cross-sections for flexible cables with end sleeve, max.":"16","Connectable cable cross-sections for flexible cables with end sleeve, min.":"24","Connectable cable cross-sections for flexible cables without end sleeve, max.":"16","Connectable cable cross-sections for flexible cables without end sleeve, min.":"24","Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04":"Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/9ab9d44602e39f4c988c31023afd2163.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=1646621&mlfb=6AG1593-0AB00-7AA0"},"ai":{"faq":[{"question":"What temperature range does this fan support?","answer":"Rated for -40°C to 70°C ambient, with the conformal coating handling condensation and corrosive gases within that range."},{"question":"What does the red LED alarm indicate?","answer":"The red LED switches on when the fan is at standstill or running at low speed, giving a visual warning that the fan needs attention."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1593-0AB00-7AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1593-0AB00-7AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-08-11T15:51:03.652Z","lastPublished":"2026-08-11T15:51:03.652Z","indexable":true}}