{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1642-0DC01-4AX1","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1642-0DC01-4AX1","canonicalUrl":"https://aoctrl.com/siemens/6AG1642-0DC01-4AX1","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1642-0DC01-4AX1","rawCanonicalId":null},"summary":{"shortDescription":"Siemens 6AG1642-0DC01-4AX1 HMI operator panel, S5 PROFIBUS DP, MPI, Sm@rtServer, hardware clock, -20 to 60 °C, IP20 rear.","salesMarkdown":"## Fieldbus and controller compatibility The 6AG1642-0DC01-4AX1: This HMI communicates exclusively over PROFIBUS DP (S5 protocol) and MPI — no Ethernet or PROFINET port on board. It connects directly to S7-200 and S7-300/400 CPUs over the MPI network, or to S5 controllers via the PROFIBUS DP interface. The absence of a serial port means legacy point-to-point links (PPI, TI 505) are not supported. ## Environmental and clock specs Rated for -20 to 60 °C ambient — the wide span suits unheated plant floors or cabinet interiors near process heat. The hardware clock is synchronizable over the network but carries no battery backup; time is lost on power-down unless the PLC master re-syncs at each startup. Rear protection is IP20, so the unit is intended for enclosure mounting with the front panel exposed. ## Software and remote access Sm@rtServer is enabled, allowing remote HMI access via a web browser — useful for diagnostics or monitoring without a local programming cable. The unit supports 500 icons, trend display, bit messages, limit-value monitoring, and a help system. Animation, color change, and a clean-screen function are present. Simulation mode is available for offline testing of HMI logic without a connected controller.","metaTitle":"Siemens 6AG1642-0DC01-4AX1 HMI, PROFIBUS DP, -20 to 60 °C","metaDescription":"Siemens 6AG1642-0DC01-4AX1 HMI with S5 PROFIBUS DP, MPI, Sm@rtServer. Operating range -20 to 60 °C. Quoted to order against RFQ.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"S5":"Yes; only PROFIBUS DP","MPI":"Yes","Hide":"Yes","Max.":"60 °C","Min.":"-20 °C","Type":"Hardware clock, synchronizable, no battery backup","Icons":"500","Lines":"1","cULus":"No","Return":"Yes","S7-200":"Yes","Serial":"No","TI 505":"No","Animate":"Yes","CF card":"No","Methods":"Trend","PC card":"No","Ethernet":"No","PROFINET":"No","IP (rear)":"IP20","Libraries":"Yes","Retentive":"No","Key repeat":"No","S7-300/400":"Yes","Simulation":"Yes","Structures":"No","ATEX Zone 2":"No","Help system":"Yes","PPI network":"No","PROFIBUS DP":"Yes","Peripherals":"Printer","Sm@rtServer":"Yes","System keys":"Yes","ATEX Zone 22":"No","Bit messages":"Yes","CF card slot":"No","Clean screen":"Yes","Color change":"Yes","Free Hotline":"Yes","Limit values":"Yes","Multiplexing":"Yes","PC card slot":"No","TAB sequence":"Yes","Task planner":"Yes","Text objects":"2 500 text elements","X/Y movement":"Yes","Color display":"No","Overall depth":"45 mm","Recipe memory":"32 KB integrated Flash, expandable","Delta transfer":"Yes","Initial values":"1 000","Processor type":"ARM, 200 MHz","Status/control":"With SIMATIC S7","Synchronizable":"Yes","Type of memory":"Flash / RAM","Analog messages":"Yes","Dynamic Objects":"Diagrams, bar graphs, sliders, analog display, invisible buttons","Graphics object":"Bit maps, icons, icon (full-screen), vector graphics","Mitsubishi (FX)":"Yes","Operation, max.":"100 %; RH incl. condensation/frost permitted (no commissioning in bedewed state)","Screen diagonal":"5.7 in","Unit switchover":"No","lifecycle_stage":"current","Control elements":"Touch screen and membrane keyboard","First/last value":"Yes","Menu tree editor":"Yes","Modicon (Modbus)":"Yes","Number of colors":"4; Blue levels","Numeric keyboard":"Yes","Type Date & Time":"1 000","Acoustic Feedback":"No","Angle of rotation":"No","Design of display":"STN","Device switchover":"Yes","IP (at the front)":"IP65","Limit value lines":"Yes","Message indicator":"Yes","Mounting position":"vertical","Number of recipes":"100","Recipe management":"Yes","Touch calibration":"Yes","Configuration tool":"WinCC flexible Compact Version 2005 or higher (to be ordered separately)","Icon (full screen)":"50","Number of messages":"2 000","Recording/Printing":"Alarms, report (shift report), hardcopy","Allen Bradley (DF1)":"Yes","Bureau Veritas (BV)":"No","Interfaces/bus type":"RS 232 optional, 1x RS 422, 1x RS 485 (max. 12 Mbit/s)","Multi-key operation":"Yes","Number of variables":"1 000","System messages HMI":"Yes","System messages PLC":"Yes","Hexadecimal Keyboard":"Yes","PPI (point-to-point)":"Yes","Allen Bradley (DF485)":"No","Alphanumeric Keyboard":"Yes","Calculating functions":"Yes","EAC (formerly Gost-R)":"No","FM Class I Division 2":"No","Languages per project":"32","Number of user groups":"50","Number of user rights":"32","Open Platform Program":"Yes","Design as touch screen":"Yes; analog, resistive","Number of bit messages":"2 000","OMRON (LINK/Multilink)":"No","Password export/import":"Yes","Telemecanique (ADJUST)":"Yes","Type of supply voltage":"DC","Backup/Restore manually":"Yes","Data records per recipe":"200","Entries per data record":"200","Germanischer Lloyd (GL)":"No","Height of housing front":"212 mm","Index of screen context":"No","Number of alarm classes":"32","Number of function keys":"32","Connection to controller":"S5, S7-200, S7- 300/400, Win AC, SINUMERIK, SIMOTION, Allen Bradley (DF1), Mitsubishi (FX), Telemecanique (ADJUST), Modicon (Modbus), for further non-Siemens drivers, see section on \"System interfaces\"","Det Norske Veritas (DNV)":"No","Number of USB interfaces":"1","Number of bars per chart":"5","Permanent window/default":"Yes","Number of analog messages":"50","Number of password fields":"1 000","Start screen configurable":"Yes","Trace (operation archive)":"No","Transfer of configuration":"MPI/PROFIBUS DP, serial, USB, by means of external storage medium, automatic transfer recognition","Number of date/time fields":"30","Number of numerical fields":"1 000","Weight (without packaging)":"1 kg","Width of the housing front":"243 mm","Number of RS 422 interfaces":"1","Number of RS 485 interfaces":"1","Starting current inrush I2t":"0.5 A²·s","Multimedia card/SD card slot":"combined","Polski Rejestr Statkow (PRS)":"No","MTBF backlighting (at 25 °C)":"50 000 h","Number of configurable images":"500","Number of objects per project":"500","Suitable for safety functions":"No","Memory available for user data":"2 048 kbyte","Number of variables per device":"1 000","Number of variables per screen":"50","Pre-Installed Operating System":"Windows CE","Process value display (output)":"Yes","Customer-specific configuration":"Yes","Number of alphanumerical fields":"1 000","Number of entries per text list":"30","Number of acknowledgement groups":"99","Number of characters per message":"80","Number of text lists per project":"300","American Bureau of Shipping (ABS)":"No","Current consumption (rated value)":"0.24 A","Lloyds Register of Shipping (LRS)":"No","Number of function keys with LEDs":"26","Number of characters per info text":"70","Number of configurable system keys":"32","Number of online/runtime languages":"5","Number of signal lamps per project":"1 000","Telegram message procedure Alarm S":"No","User-Definable Label Membrane Keys":"Yes","Number of entries per graphics list":"30","Number of graphics lists per project":"100","Number of process values per message":"8","Number of decade switches per project":"0","Number of status switches per project":"1 000","Number of visible switches per project":"1 000","Process value default (input) possible":"Yes","Additional software components loadable":"Yes","Number of selector switches per project":"1 000","Number of industrial Ethernet interfaces":"0","Monitoring function for battery and memory":"No","SIMATIC HMI MM memory card: Multi Media Card":"Yes","Alarm system (incl. buffer and acknowledgment)":"Yes","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 080 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... )":"No","Maximum Permissible Angle Of Inclination Without External Ventilation":"35°"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=142213&mlfb=6AG1642-0DC01-4AX1","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AG1642-0DC01-4AX1/alternatives.json"},"ai":{"faq":[{"question":"What controllers can the 6AG1642-0DC01-4AX1 connect to?","answer":"It connects to Siemens S7-200 and S7-300/400 CPUs via MPI, and to S5 controllers over PROFIBUS DP. No Ethernet or PROFINET connectivity is available."},{"question":"Does the 6AG1642-0DC01-4AX1 have a battery-backed clock?","answer":"No. The hardware clock is synchronizable over the network but has no battery backup. Time is lost on power-down unless re-synchronized by the PLC master."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1642-0DC01-4AX1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1642-0DC01-4AX1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}