{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1647-0AA11-2AX0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1647-0AA11-2AX0","canonicalUrl":"https://aoctrl.com/siemens/6AG1647-0AA11-2AX0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1647-0AA11-2AX0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC HMI, 6AG1647-0AA11-2AX0, PROFINET interface, DCP, DHCP, SNMP, MODBUS TCP/IP, EtherNet/IP, IP20, plastic housing, -20 to 60 °C.","salesMarkdown":"## PROFINET HMI with multi-protocol Ethernet The Siemens 6AG1647-0AA11-2AX0 is a SIMATIC HMI panel with a native PROFINET interface and support for DCP (Discovery and Configuration Protocol), DHCP, LLDP, and SNMP for network integration. It also runs MODBUS TCP/IP and EtherNet/IP stacks, so it can talk to a Rockwell PLC or a Modicon controller on the same wire without a gateway. ## Protocol support and integration notes This HMI does not have a USB host port, so firmware updates or recipe transfers must go over Ethernet. It also lacks MPI and PROFIBUS — if your existing network is DP-based, you'll need a gateway or a different panel. S7-300/400 controllers are supported natively over PROFINET; S7-200 requires a CP module. The unit includes onboard flash memory for project storage and a task planner for scheduled screen changes or data logging. Simulation mode is available for offline testing of HMI logic before deployment. For the controls integrator: this panel can serve as a multi-vendor HMI on a mixed network. The Ethernet port handles PROFINET IO, MODBUS TCP, and EtherNet/IP concurrently — no protocol switching required. Just assign the IP via DCP or DHCP and point it at the controller tag table.","metaTitle":"Siemens 6AG1647-0AA11-2AX0 HMI, PROFINET, DCP, -20 to 60 °C","metaDescription":"Siemens 6AG1647-0AA11-2AX0 HMI panel with PROFINET, DCP, DHCP, SNMP, MODBUS TCP/IP, EtherNet/IP. IP20. Sourced to order against RFQ. -20 to 60 °C operating range.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["HMI Operator Interfaces"],"specifications":{"DCP":"Yes","MPI":"No","RAM":"Yes","USB":"No","DHCP":"Yes","LLDP":"Yes","Max.":"60 °C","Min.":"-20 °C","SNMP":"Yes","Flash":"Yes","MODBUS":"Yes; Modicon (MODBUS TCP/IP)","S7-200":"Yes; Via CP","TCP/IP":"Yes","Plastic":"Yes","Printer":"No","Aluminum":"No","Ethernet":"Yes","PROFIBUS":"No","PROFINET":"Yes","SIMOTION":"No","Acoustics":"Sound signal","IP (rear)":"IP20","Libraries":"Yes","SINUMERIK":"No","S7-300/400":"Yes","Simulation":"Yes","Structures":"No","US English":"Yes","USB memory":"No","EtherNet/IP":"Yes","Help system":"Yes","System keys":"No","Web browser":"No","Bit messages":"Yes","Limit values":"Yes","Multiplexing":"Yes","Task planner":"Yes","Display width":"76.8 mm","Keys with LED":"No","Overall depth":"40 mm","Rack mounting":"No","Display height":"57.6 mm","Keyboard fonts":"US American (English)","Message buffer":"Ring buffer (n x 256 entries), non-retentive","Processor type":"RISC 32 bit","Software clock":"Yes","Status/control":"No","Analog messages":"Yes","MPI/PROFIBUS DP":"No","Mitsubishi (FX)":"No","Screen diagonal":"3.8 in","lifecycle_stage":"current","Modicon (Modbus)":"No","Numeric keyboard":"Yes; Onscreen keyboard","Design of display":"STN","Device switchover":"Yes","IP (at the front)":"IP65","Message indicator":"Yes","Mounting position":"vertical","Number of entries":"256","Number of recipes":"5","Recipe management":"Yes","Circulating buffer":"Yes","Allen Bradley (DF1)":"No","System messages HMI":"Yes","Alphanumeric Keyboard":"Yes; Onscreen keyboard","Languages per project":"32","Number of user groups":"50","Number of user rights":"32","Suited for indoor use":"Yes","Design as touch screen":"Yes","Mounting cutout, width":"123 mm","Number of bit messages":"200","OMRON (LINK/Multilink)":"No","Password export/import":"No","Suited for outdoor use":"No","Type of supply voltage":"DC","Backup/Restore manually":"Yes","Data records per recipe":"20","Entries per data record":"20","Height of housing front":"116 mm","Mounting cutout, height":"99 mm","Number of alarm classes":"32","Number of function keys":"4","Weight (with packaging)":"0.53 kg","Number of USB interfaces":"0","Permanent window/default":"Yes; No permanent window can be configured","Recipe memory expandable":"No","With software interfaces":"No","Number of analog messages":"15","SIMATIC WinCC Sm@rtServer":"No","Number of other interfaces":"0","Weight (without packaging)":"0.32 kg","Width of the housing front":"140 mm","At maximum tilt angle, max.":"40 °C","At maximum tilt angle, min.":"-10 °C","Number of RS 232 interfaces":"0","Number of RS 422 interfaces":"0","Number of RS 485 interfaces":"0","Starting current inrush I2t":"0.5 A²·s","MTBF backlighting (at 25 °C)":"30 000 h","Number of configurable images":"50","Number of parallel interfaces":"0","Using External Storage Medium":"No","Wall mounting/direct mounting":"No","Industrial Ethernet status LED":"2","Memory available for user data":"512 kbyte","Number of variables per device":"128","Number of variables per screen":"30","Process value display (output)":"Yes","Size of internal recipe memory":"40 kbyte","For vertical installation, max.":"60 °C","For vertical installation, min.":"-10 °C","Number of 20 mA interfaces (TTY)":"0","Number of characters per message":"80","Number of text lists per project":"150","Number of function keys with LEDs":"0","Supports protocol for PROFINET IO":"No","Number of characters per info text":"320","Number of online/runtime languages":"5","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Number of graphics lists per project":"100","Number of process values per message":"8","Process value default (input) possible":"Yes","Number of industrial Ethernet interfaces":"1","Installation altitude above sea level, max.":"5 000 m","SIMATIC HMI MM memory card: Multi Media Card":"No","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Alarm system (incl. buffer and acknowledgment)":"Yes","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","SIMATIC HMI SD memory card: Secure Digital memory card":"No","System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... )":"No","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Maximum Permissible Angle Of Inclination Without External Ventilation":"35°","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$756.92","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=149300&mlfb=6AG1647-0AA11-2AX0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AG1647-0AA11-2AX0/alternatives.json"},"ai":{"faq":[{"question":"What protocols does 6AG1647-0AA11-2AX0 support?","answer":"It supports PROFINET, MODBUS TCP/IP, EtherNet/IP, DCP, DHCP, LLDP, and SNMP. It does not support MPI, PROFIBUS, or USB host."},{"question":"What is the operating temperature range for this HMI?","answer":"The operating temperature range is -20 to 60 °C. The rear enclosure is IP20, so it must be installed inside a control cabinet."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1647-0AA11-2AX0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1647-0AA11-2AX0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}