{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1647-0AG11-4AX0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1647-0AG11-4AX0","canonicalUrl":"https://aoctrl.com/siemens/6AG1647-0AG11-4AX0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1647-0AG11-4AX0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC HMI, 6AG1647-0AG11-4AX0, 304.1 mm display width, 60 mm depth, IP20 rear, PROFINET, EtherNet/IP, MODBUS TCP, DCP support.","salesMarkdown":"## What this HMI panel brings to the panel door The Siemens 6AG1647-0AG11-4AX0 is a SIMATIC HMI panel with a 304.1 mm display width and 60 mm overall depth — sized for a cutout that fits standard enclosure doors without eating into wiring space behind the gland plate. Rear protection is IP20, so it belongs in a sealed cabinet, not on a washdown station. Onboard Ethernet carries PROFINET, EtherNet/IP, and MODBUS TCP natively — no separate comm module needed for multi-vendor lines. DCP (Discovery and Configuration Protocol) is supported, so the panel picks up its IP address automatically on a PROFINET network, saving a step during commissioning. It integrates directly with S7-300/400 controllers over the backplane or via the Ethernet link. For S7-200 plants, it connects through a CP (communications processor) — not direct, but workable with the right adapter. ## Network and protocol fit — no extra cards DHCP and LLDP are both enabled, meaning the panel can auto-negotiate its address and topology discovery on managed switches. SNMP support lets the plant network team poll it for status without walking to the cabinet. No PROFIBUS or MPI onboard — if the existing line uses those fieldbuses, this panel needs a gateway or a different HMI variant. The Ethernet-only interface keeps the BOM clean for new installs but rules out legacy Profibus drops.","metaTitle":"Siemens 6AG1647-0AG11-4AX0 HMI Panel, 304.1 mm Display, IP20","metaDescription":"Siemens 6AG1647-0AG11-4AX0 HMI panel with 304.1 mm display, IP20 rear, DCP support. Sourced to order against RFQ. Available through independent distribution.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["HMI Operator Interfaces"],"specifications":{"DCP":"Yes","MPI":"No","RAM":"Yes","USB":"No","DHCP":"Yes","LLDP":"Yes","SNMP":"Yes","Flash":"Yes","WinAC":"No","MODBUS":"Yes","S7-200":"Yes; Via CP","TCP/IP":"Yes","Plastic":"Yes","Printer":"No","Aluminum":"No","Ethernet":"Yes","PROFIBUS":"No","PROFINET":"Yes","SIMOTION":"No","Acoustics":"Sound signal","IP (rear)":"IP20","Libraries":"Yes","SINUMERIK":"No","S7-300/400":"Yes","Simulation":"Yes","Structures":"No","US English":"Yes","USB memory":"No","EtherNet/IP":"Yes","Help system":"Yes","System keys":"No","Web browser":"No","Bit messages":"Yes","Limit values":"Yes","Multiplexing":"Yes","Task planner":"Yes","Display width":"304.1 mm","Keys with LED":"No","Overall depth":"60 mm","Rack mounting":"No","Display height":"228.1 mm","Keyboard fonts":"US American (English)","Message buffer":"Ring buffer (n x 256 entries), retentive, maintenance-free","Processor type":"RISC 32 bit","Software clock":"Yes","Status/control":"No","Analog messages":"Yes","MPI/PROFIBUS DP":"No","Mitsubishi (FX)":"No","Screen diagonal":"15 in","lifecycle_stage":"current","Modicon (Modbus)":"Yes; MODBUS TCP/IP protocol","Number of colors":"256","Numeric keyboard":"Yes; Onscreen keyboard","Design of display":"TFT","Device switchover":"Yes","IP (at the front)":"IP65","Message indicator":"Yes","Mounting position":"vertical","Number of entries":"256","Number of recipes":"5","Recipe management":"Yes","Circulating buffer":"Yes","Allen Bradley (DF1)":"No","System messages HMI":"Yes","Alphanumeric Keyboard":"Yes; Onscreen keyboard","Languages per project":"32","Number of user groups":"50","Number of user rights":"32","Suited for indoor use":"Yes","Design as touch screen":"Yes","Mounting cutout, width":"367 mm","Number of bit messages":"200","OMRON (LINK/Multilink)":"No","Password export/import":"No","Suited for outdoor use":"No","Type of supply voltage":"DC","Backup/Restore manually":"Yes","Data records per recipe":"20","Entries per data record":"20","Height of housing front":"310 mm","Mounting cutout, height":"289 mm","Number of alarm classes":"32","Number of function keys":"0","Weight (with packaging)":"4.68 kg","Number of USB interfaces":"0","Permanent window/default":"Yes; No permanent window can be configured","Recipe memory expandable":"No","With software interfaces":"No","Number of analog messages":"15","SIMATIC WinCC Sm@rtServer":"No","Number of other interfaces":"0","Weight (without packaging)":"4.2 kg","Width of the housing front":"400 mm","At maximum tilt angle, max.":"40 °C; = Tmax","At maximum tilt angle, min.":"0 °C; = Tmin","Number of RS 232 interfaces":"0","Number of RS 422 interfaces":"0","Number of RS 485 interfaces":"0","Starting current inrush I2t":"0.2 A²·s","MTBF backlighting (at 25 °C)":"50 000 h","Number of configurable images":"50","Number of parallel interfaces":"0","Using External Storage Medium":"No","Wall mounting/direct mounting":"No","Industrial Ethernet status LED":"2","Memory available for user data":"1 024 kbyte","Number of variables per device":"500","Number of variables per screen":"30","Process value display (output)":"Yes","Size of internal recipe memory":"40 kbyte","For vertical installation, max.":"50 °C; = Tmax","For vertical installation, min.":"0 °C; = Tmin","Number of 20 mA interfaces (TTY)":"0","Number of characters per message":"80","Number of text lists per project":"150","Number of function keys with LEDs":"0","Supports protocol for PROFINET IO":"No","Number of characters per info text":"320","Number of online/runtime languages":"5","permissible range, lower limit (DC)":"19.2 V","permissible range, upper limit (DC)":"28.8 V","Number of graphics lists per project":"100","Number of process values per message":"8","Process value default (input) possible":"Yes","Number of industrial Ethernet interfaces":"1","Installation altitude above sea level, max.":"5 000 m","SIMATIC HMI MM memory card: Multi Media Card":"No","Protection against fouling acc. to EN 60664-3":"Yes; Type 1 protection","Alarm system (incl. buffer and acknowledgment)":"Yes","Ambient air temperature-barometric pressure-altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)","SIMATIC HMI SD memory card: Secure Digital memory card":"No","System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... )":"No","Resistant to commercially available coolants and lubricants":"Yes; Incl. diesel and oil droplets in the air","Maximum Permissible Angle Of Inclination Without External Ventilation":"35°","Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A":"Yes; Conformal coating, Class A"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=71363&mlfb=6AG1647-0AG11-4AX0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AG1647-0AG11-4AX0/alternatives.json"},"ai":{"faq":[{"question":"What protocols does 6AG1647-0AG11-4AX0 support?","answer":"It supports PROFINET, EtherNet/IP, and MODBUS TCP natively, plus DCP, DHCP, LLDP, and SNMP for network management. No PROFIBUS or MPI onboard."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1647-0AG11-4AX0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1647-0AG11-4AX0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}