{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1677-1DD00-4BB0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1677-1DD00-4BB0","canonicalUrl":"https://aoctrl.com/siemens/6AG1677-1DD00-4BB0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1677-1DD00-4BB0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SIMATIC WinAC RTX 2009 software controller, Type SFB, 1 GB RAM, 2 GB flash, 8,000 I/O, -40 to 70 °C, CFC/FBD/LAD/SCL/STL/GRAPH.","salesMarkdown":"## Software PLC with full IEC language suite The 6AG1677-1DD00-4BB0: Onboard memory: 1 GB main RAM plus a 2 GB flash disk for program and data storage. Temperature range -40 to 70 °C means it survives unheated cabinets and hot panel environments. The two USB 2.0 high-speed ports let you plug in a memory stick or keyboard for local service. IRT (isochronous real-time) is listed as supported—this matters if you're syncing drives or fast I/O. Send cycles are adjustable down to 250 µs, giving deterministic update rates for motion coordination.","metaTitle":"6AG1677-1DD00-4BB0 Siemens WinAC RTX 2009 Soft-PLC, 1GB RAM","metaDescription":"SIMATIC WinAC RTX 2009 software-based controller with 2 GB flash, 8,000 I/O, IEC languages (CFC, FBD, LAD, SCL). CE marked. Sourced to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"CFC":"Yes","FBD":"Yes","IRT":"Yes","LAD":"Yes","MPI":"No","SCL":"Yes","STL":"Yes","UDP":"Yes; Via integrated PROFINET interface (X1) and loadable FBs","Max.":"70 °C","Min.":"-40 °C","Type":"SFB","Depth":"115 mm","GRAPH":"Yes","Width":"160 mm","cULus":"No","Height":"125 mm","Inputs":"8 000","Number":"2 048","Preset":"8","STEP 7":"Yes","TCP/IP":"Yes; Via integrated PROFINET interface (X1) and loadable FBs","CE mark":"Yes","Control":"SIMATIC WinAC RTX 2009","Forcing":"No","Outputs":"8 000","Overall":"64","Present":"Yes","USB port":"2 x USB 2.0 high speed/high current","As Client":"Yes","As Server":"Yes","HiGraph®":"Yes","Supported":"Yes","Adjustable":"Yes","Flash Disk":"2 GB","S7 routing":"Yes","Size, max.":"64 kbyte","FM approval":"No","Lower Limit":"10 ms","Main memory":"1 GB RAM","Send cycles":"Adjustable: 250 µs, 500 µs and 1 ms","Upper Limit":"9 990 s","Autocrossing":"No","CSA approval":"No","Inputs, max.":"16 kbyte","Number, max.":"16 kbyte","PROFINET CBA":"No","Communication":"Yes","Outputs, max.":"16 kbyte","Interface type":"Integrated Ethernet interface","Processor type":"Intel Core Duo 1.2 GHz","Type of memory":"512 KB non-volatile memory for retentive data","Updating times":"250 µs - 128 ms (with signal cycle 250 µs); 500 µs - 256 ms (with signal cycle 500 µs); 1 ms - 512 ms (with signal cycle 1 ms)","Autonegotiation":"Yes","Inputs, default":"512 byte","Number of ports":"2","lifecycle_stage":"current","to PC-CP, slave":"Yes","Firmware version":"V1.3","Isochronous mode":"No","Outputs, default":"512 byte","Power loss, typ.":"34 W","RJ 45 (Ethernet)":"Yes","Rated value (DC)":"24 V","S7 communication":"Yes","Data length, max.":"1 472 byte","PROFIBUS DP slave":"No","Inputs, adjustable":"16 kbyte","PROFIBUS DP master":"No","PROFINET IO Device":"No","Per Priority Class":"24","Reference platform":"SIMATIC S7 modular embedded controller","Retentivity preset":"MB 0 to MB 15","Cyclic Transmission":"Yes","Outputs, adjustable":"16 kbyte","PG/OP communication":"Yes","Prioritized startup":"Yes","Acyclic Transmission":"Yes","HW functional status":"04","ISO-on-TCP (RFC1006)":"No","Number of startup OBs":"2; OB 100, 102","Open IE communication":"Yes","RCM (formerly C-TICK)":"No","PROFINET IO Controller":"No","Rated value at 24 V DC":"800 mA; without backplane bus and USB power supply","Integrated power supply":"Yes","Status/control variable":"Yes","For Bit Operations, Typ.":"0.004 µs; Typical","Number of clock memories":"8","Number of free cycle OBs":"1; OB 1","Number of time alarm OBs":"1; OB 10","Number of delay alarm OBs":"1; OB 20","Point-to-point connection":"No","Hardware clock (real-time)":"Yes; Resolution: 1 s","Number of connections, max.":"32","Number of process alarm OBs":"1; OB 40","Process diagnostic messages":"Yes; Alarm_S","User data consistency, max.":"256 byte","additional within an error OB":"24","reserved for OP communication":"1","reserved for PG communication":"1","Number of connection resources":"32","Number of cyclic interrupt OBs":"9; OB 30-38","Pre-Installed Operating System":"Windows XP embedded SP2 FP2007","Number of synchronous error OBs":"2; OB 121, 122","Topology recognition, supported":"Yes; LLDP, LLDP MIB, SNMP","For Fixed Point Arithmetic, Typ.":"0.003 µs; Typical","Number of asynchronous error OBs":"7; OB 80, 82-85, 86, 88","User data per address area, max.":"2 kbyte","Number of subprocess images, max.":"15","Of Which Retentive Without Battery":"MB 0 to MB 16383","tested according to IEC 60068-2-27":"Yes","tested according to IEC 60068-2-29":"Yes","For Floating Point Arithmetic, Typ.":"0.004 µs; Typical","Number of IO Devices per tool, max.":"8","permissible range, lower limit (DC)":"20.4 V","permissible range, upper limit (DC)":"28.8 V","Activation/deactivation of IO Devices":"Yes","Degree of protection acc. to EN 60529":"IP20","Number of connectable IO Devices, max.":"256","Assignment of the IP address, supported":"Yes; DCP","Transport, tested acc. to IEC 60068-2-6":"Yes","Assignment of the device name, supported":"Yes; DCP","Automatic Detection Of Transmission Rate":"Yes","Detection of accessible nodes, supported":"Yes; DCP","Mains/voltage failure stored energy time":"5 ms","Local port numbers used at the system end":"0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535","Limit class A, for use in industrial areas":"Yes","Operation, tested according to IEC 60068-2-6":"Yes","Number of IO devices with prioritized startup, max.":"32","Number of login stations for message functions, max.":"62; The alarm functions cannot currently be used for central bus modules","Retentive data area (incl. timers, counters, flags), max.":"512 kbyte","extended network diagnostics with Standard MIB II, supported":"Yes; Standard MIB II, SNMP","IO Devices changing during operation (partner ports), supported":"Yes","Number of IO Devices with IRT and the option \"high flexibility\"":"64","Number of IO Devices that can be simultaneously activated/deactivated, max.":"8"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/5b1aee31713b404eecf2f85e783c1d8f.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=271350&mlfb=6AG1677-1DD00-4BB0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AG1677-1DD00-4BB0/alternatives.json"},"ai":{"faq":[{"question":"Does the 6AG1677-1DD00-4BB0 support CFC and FBD programming?","answer":"Yes, both CFC and FBD are listed as supported languages."},{"question":"What is the operating temperature range?","answer":"Rated for -40 °C minimum to 70 °C maximum ambient."},{"question":"Is CE marking present?","answer":"Yes, the CE mark is listed as present. No RoHS or REACH documentation is specified in the record."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1677-1DD00-4BB0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1677-1DD00-4BB0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}