{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AG1800-4BA00-7AA0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AG1800-4BA00-7AA0","canonicalUrl":"https://aoctrl.com/siemens/6AG1800-4BA00-7AA0","factsUrl":"https://aoctrl.com/api/mcp/products/6AG1800-4BA00-7AA0","rawCanonicalId":null},"summary":{"shortDescription":"Siemens SINAUT TIM, S7-300 double-width module, 20.4–28.8 V DC, for ST1/ST7 telecontrol protocols, IP20, active production.","salesMarkdown":"The Siemens 6AG1800-4BA00-7AA0 is a SINAUT TIM module occupying double-width in an S7-300 rack. It handles ST1 and ST7 protocols over Industrial Ethernet and serial interfaces, with a C-PLUG slot. Supply is 20.4–28.8 V DC, pulling 4.6 W.","metaTitle":"Siemens 6AG1800-4BA00-7AA0 SINAUT TIM, Active Component","metaDescription":"Siemens 6AG1800-4BA00-7AA0 SINAUT TIM communication module for S7-300. 20.4–28.8 V DC, double-width, supports ST1/ST7 protocols, C-PLUG. Active lifecycle, quoted to order.","metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["PLCs (Programmable Logic Controllers)"],"specifications":{"Note":"TD7onCPU: at least 20 KB, actual requirement determined by data volume and functional scope TD7onTIM: 0 bytes in most favorable case","Depth":"120 mm","Width":"80 mm","C-PLUG":"Yes","Height":"125 mm","Maximum":"64","Typical":"100 µA","Required":"SINAUT ST7 ES","Substation":"Yes","Node Station":"Yes","Module Format":"Compact module S7-300 double width","During Storage":"-40 ... +70 °C","Supply Voltage":"20.4 ... 28.8 V","power loss [W]":"4.6 W","Type Of Battery":"Lithium AA / 3.6 V / 2.3 Ah","lifecycle_stage":"current","During Operation":"-25 ... +70 °C","During Transport":"-40 ... +70 °C","For Power Supply":"2-pole plugable terminal block","TIM control center":"Yes","PG/OP communication":"Yes","SINAUT ST1 protocol":"Yes","SINAUT ST7 protocol":"Yes","according to RS 232":"50 ... 38400 bit/s","protection class IP":"IP20","Security Information":"Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. Siemens products and solutions undergo continuous development with this factor in mind. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable protective measures (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Third-party products that may be in use should also be considered. You can find more information on Industrial Security at http://www.siemens.com/industrialsecurity. In order to keep yourself informed about product updates, we recommend subscribing to our product-specific newsletter. You can find more information on this at http://support.automation.siemens.com. Version 3.4 � 14.11.2013- Siemens AG, I IA L CG, Nuremberg","for Industrial Ethernet":"10 ... 100 Mbit/s","for SINAUT ST1 protocol":"4","for SINAUT ST7 protocol":"4","with OP connections / maximum":"62","with PG connections / maximum":"2","SINAUT ST7 via S7 communication":"Yes","with RS 232 interface / maximum":"6 m","with RS 485 interface / maximum":"30 m","of Industrial Ethernet interface":"RJ45 port","conformity according to EN 60721-3-3":"Yes; Class 3S4 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation.","conformity according to EN 60721-3-6":"Yes; Class 6S3 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation.","Type Of Voltage / Of The Supply Voltage":"DC","Product Component / Hardware Real Time Clock":"Yes","storage location / of TIM configuration data":"on internal TIM flash memory, or on TIM in optional C‑PLUG, or on MMC of the S7-300 CPU if TIM installed in S7-300 controller","Product Extension / Optional / Backup Battery":"Yes","for SINAUT ST1 protocol with polling / 11 bit":"Yes","from backplane bus / at DC / at 24 V / maximum":"0.2 A","operating mode / Virtual Private Network (VPN)":"Yes","At Interface 1 / For External Data Transmission":"9 pin Sub-D-connector, RS232 switchable to RS485","At Interface 2 / For External Data Transmission":"9-pole D-sub connector, RS232 can be switched to RS485","Product Feature / Buffered Message Frame Memory":"Yes","supply voltage / external / at DC / rated value":"20.4 ... 28.8 V","with Virtual Private Network MSC / is supported":"TCP/IP","with dial-up network / with SINAUT ST1 protocol":"spontaneous","with dial-up network / with SINAUT ST7 protocol":"spontaneous","for external data transmission / according to RS 232":"2","Number Of Active Connections / With Multi-Protocol Mode":"128","number of interfaces / according to Industrial Ethernet":"2","for SINAUT ST7 protocol with multi-master polling / 10-bit":"Yes","Product Feature / Hardware Real Time Clock W. Battery Backup":"Yes","Chemical Resistance / To Commercially Available Cooling Lubricants":"Yes; incl. airborne diesel and oil droplets","Ambient Condition / Relating To Ambient Temperature - Air Pressure - Installation Altitude":"Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) // Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500 m) // Tmin ... (Tmax - 20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5 000 m)"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":null,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/a1b88c56f3e76c79f43814434a699eec.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=38463&mlfb=6AG1800-4BA00-7AA0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AG1800-4BA00-7AA0/alternatives.json"},"ai":{"faq":[{"question":"What are the key memory requirements for the TD7 application on the CPU?","answer":"The TD7onCPU requires at least 20 KB; actual need depends on data volume and functional scope. On the TIM itself, the requirement can be 0 bytes in the most favorable case."},{"question":"What is the physical size of this module?","answer":"The module has dimensions of 125 mm height, 80 mm width, and 120 mm depth. It occupies two slots in an S7-300 rack."}],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AG1800-4BA00-7AA0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AG1800-4BA00-7AA0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}