{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AV6542-0DA10-0AX0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AV6542-0DA10-0AX0","canonicalUrl":"https://aoctrl.com/siemens/6AV6542-0DA10-0AX0","factsUrl":"https://aoctrl.com/api/mcp/products/6AV6542-0DA10-0AX0","rawCanonicalId":null},"summary":{"shortDescription":"***Spare part*** SIMATIC Multi Panel MP 370 12\" color TFT display, Keys Windows CE 3.0 configurable with ProTool From Version V5.2+SP3","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["HMI Operator Interfaces"],"specifications":{"S5":"Yes","CSV":"Yes","MPI":"Yes","TXT":"No","Hide":"Yes","Max.":"60 °C","Min.":"-20 °C","Type":"Hardware clock, battery backup, synchronizable","Icons":"2 000","Lines":"1","CD-ROM":"No","Change":"Yes","Cyclic":"Yes","Return":"Yes","S7-200":"Yes","Serial":"Yes","TI 505":"Yes","Animate":"Yes","CF card":"Yes","Methods":"Trend / profile","PC card":"Yes","Ethernet":"Yes","Info LED":"Yes","PROFINET":"Yes","USB port":"Yes; 1x USB","Error LED":"Yes","Hard disk":"No","IP (rear)":"IP20","Libraries":"Yes","Power LED":"No","Retentive":"Yes; yes, via optional battery","Tolerance":"Yes","Key repeat":"Yes","S7-300/400":"Yes","Simulation":"Yes","Structures":"Yes","USB memory":"No","Help system":"Yes","PPI network":"Yes","PROFIBUS DP":"Yes","Peripherals":"Printer, barcode reader","Bit messages":"Yes","CF card slot":"1x CF card slot","Clean screen":"No","Color change":"Yes","Free Hotline":"Yes","Limit values":"Yes","Multiplexing":"Yes","PC card slot":"1x PC card slot","TAB sequence":"Yes","Task planner":"Yes","Text objects":"30 000 text elements","X/Y movement":"Yes","Overall depth":"59 mm","Recipe memory":"128 KB integrated Flash, expandable","Delta transfer":"Yes","Diskette drive":"No","GE-Fanuc (SNP)":"Yes","Initial values":"2 048","Processor type":"MIPS","Status/control":"With SIMATIC S7","Synchronizable":"Yes","Type of memory":"Flash / RAM","Analog messages":"Yes","Dynamic Objects":"Diagrams, bar graphs, sliders, analog display, invisible buttons","Graphics object":"Bit maps, icons, vector graphics","Memory location":"PC card, CF card, Ethernet","Message archive":"Yes","Mitsubishi (FX)":"Yes","Operation, max.":"85 %","Screen diagonal":"12.1 in","Size of archive":"depending on free memory on ext. card/stick or on free hard disk space via network drive","Unit switchover":"No","lifecycle_stage":"mature","Control elements":"Membrane keyboard","First/last value":"Yes","Menu tree editor":"No","Mitsubishi (MP4)":"Yes","Modicon (Modbus)":"Yes","Numeric keyboard":"Yes","Type Date & Time":"2 048","Acoustic Feedback":"No","Angle of rotation":"No","Archiving methods":"Sequential log, circular log, alarm log, process value archive","Backup time, min.":"3 y","Design of display":"TFT, 256 colors","Device switchover":"Yes","IP (at the front)":"IP65","Limit value lines":"Yes","Membrane keyboard":"Yes","Message indicator":"Yes","Mounting position":"vertical","Number of recipes":"500","Online evaluation":"via trends","Touch calibration":"No","Configuration tool":"ProTool Version 5.2 SP 3 or higher, or WinCC flexible Standard Version 2004 or higher (to be ordered separately)","Icon (full screen)":"0","Number of messages":"4 000","Number of tooltips":"0","Recording/Printing":"Alarms, report (shift report), color print, hardcopy","Sequential archive":"Yes","Short-term archive":"Yes","Using Trend Curves":"Yes","Allen Bradley (DF1)":"Yes","Data storage format":"CSV file, readable, e.g. with MS Excel, MS Access","External Evaluation":"readable, e.g. with MS Excel, MS Access, etc.","Interfaces/bus type":"1x TTY, 2x RS 232, 1x RS 422, 1x RS 485, 1x Ethernet (RJ45) (max. 12 Mbit/s)","Multi-key operation":"Yes","Number of variables":"2 000","System messages HMI":"Yes","System messages PLC":"Yes","Hexadecimal Keyboard":"Yes","PPI (point-to-point)":"Yes","Acknowledgment groups":"Yes","Allen Bradley (DF485)":"Yes","Alphanumeric Keyboard":"Yes","Calculating functions":"Yes","Languages per project":"32","Number of system keys":"38","Number of user groups":"50","Number of user rights":"32","Open Platform Program":"Yes","Process value archive":"Yes","Design as touch screen":"No","Illuminated pushbutton":"Yes","Number of bit messages":"4 000","OMRON (LINK/Multilink)":"Yes","Password export/import":"Yes","Telemecanique (ADJUST)":"Yes","Type of supply voltage":"DC","Backup/Restore manually":"Yes","Data records per recipe":"1 000","Entries per data record":"1 000","Height of housing front":"310 mm","Index of screen context":"No","Number of alarm classes":"32","Number of function keys":"36","Active power input, typ.":"28 W","Connection to controller":"S5, S7-200, S7- 300/400, TI 505, Win AC, PC (TCP/IP), SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), Telemecanique (ADJUST), OMRON (LINK/Multilink), Modicon (Modbus), for further non-Siemens drivers, see section on \"System interfaces\"","Number of bars per chart":"20","Permanent window/default":"Yes","UPS connectable (serial)":"Yes","Backup battery (optional)":"Yes; optional 3.6 V","Number of analog messages":"4 000","Number of password fields":"2 048","Start screen configurable":"Yes","Trace (operation archive)":"No","Transfer of configuration":"MPI/PROFIBUS DP, serial, USB, Ethernet, by means of external storage medium, automatic transfer recognition","Debugging in the simulator":"No","Number of date/time fields":"400","Number of numerical fields":"2 048","Telemecanique (Uni-Telway)":"Yes","Weight (without packaging)":"5.1 kg","Width of the housing front":"483 mm","Starting current inrush I2t":"0.5 A²·s","MTBF backlighting (at 25 °C)":"50 000 h","Number of archives per device":"50","Number of configurable images":"500","Number of entries per archive":"50 000","Number of objects per project":"2 000","Memory available for user data":"7 168 kbyte","Number of multi-key operations":"36","Number of variables per device":"2 048","Number of variables per screen":"400","Pre-Installed Operating System":"Windows CE","Customer-specific configuration":"No","Number of alphanumerical fields":"300","Number of entries per text list":"256","Number of characters per message":"80","Number of text lists per project":"500","Current consumption (rated value)":"1.15 A","Number of function keys with LEDs":"36","Number of characters per info text":"70","Number of online/runtime languages":"5","Number of signal lamps per project":"400","Telegram message procedure Alarm S":"Yes","User-Definable Label Membrane Keys":"Yes","Number of entries per graphics list":"256","Number of graphics lists per project":"500","Number of process values per message":"8","Number of decade switches per project":"400","Number of status switches per project":"400","Number of measuring points per project":"50","Number of visible switches per project":"400","Number of selector switches per project":"400","Monitoring function for battery and memory":"Yes","SIMATIC HMI MM memory card: Multi Media Card":"No","SIMATIC HMI SD memory card: Secure Digital memory card":"No","System messages, other (SIMATIC S7, Sinumerik, Simotion, etc.)":"Yes","Maximum Permissible Angle Of Inclination Without External Ventilation":"35°"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$899.99","priceTiers":null},"links":{"datasheetUrl":null,"sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=291394&mlfb=6AV6542-0DA10-0AX0","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AV6542-0DA10-0AX0/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AV6542-0DA10-0AX0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AV6542-0DA10-0AX0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}