{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AV6641-0CA01-0AX1","brand":"Siemens","brandSlug":"siemens","productSlug":"6AV6641-0CA01-0AX1","canonicalUrl":"https://aoctrl.com/siemens/6AV6641-0CA01-0AX1","factsUrl":"https://aoctrl.com/api/mcp/products/6AV6641-0CA01-0AX1","rawCanonicalId":null},"summary":{"shortDescription":"*** spare part *** SIMATIC Operator Panel OP 77B LC display backlit, 4.5 display graphics-capable, MPI/PROFIBUS DP interface up to 12 MB, printer/USB interface, slot for MMC, configurable with WinCC flexible 2004 Compact","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["HMI Operator Interfaces"],"specifications":{"S5":"Yes","MPI":"Yes","Hide":"Yes","Max.":"60 °C","Min.":"-20 °C","Type":"Software clock, no battery backup","Icons":"1 000","cULus":"Yes","MODBUS":"Yes","Return":"Yes","S7-200":"Yes","Serial":"Yes","TCP/IP":"No","TI 505":"Yes","Animate":"Yes","CE mark":"Yes","Ethernet":"No","Info LED":"Yes","PROFIBUS":"Yes","PROFINET":"No","Error LED":"No","IP (rear)":"IP20","Libraries":"Yes","PROFIsafe":"No","Power LED":"No","Retentive":"No","Key repeat":"Yes","S7-300/400":"Yes","Simulation":"Yes","ATEX Zone 2":"No; certificate no longer available as of 1 October 2020","EtherNet/IP":"No","Help system":"Yes","PPI network":"Yes","PROFIBUS DP":"Yes","Peripherals":"Printer","System keys":"Yes","UL approval":"Yes","ATEX Zone 22":"No; certificate no longer available as of 1 October 2020","Bit messages":"Yes","Clean screen":"No","Color change":"Yes","Free Hotline":"Yes","Limit values":"Yes","Multiplexing":"Yes","NEMA (front)":"NEMA 4x, NEMA 12 (when installed)","TAB sequence":"Yes","Task planner":"Yes","Text objects":"2 500 text elements","X/Y movement":"No","Color display":"No","Function keys":"Yes","Overall depth":"38.5 mm","Recipe memory":"32 KB integrated Flash, expandable","Delta transfer":"Yes","GE-Fanuc (SNP)":"Yes","Processor type":"ARM","Synchronizable":"No","Type of memory":"Flash / RAM","Analog messages":"Yes","Dynamic Objects":"Bar graphs","Graphics object":"Bit maps, icons, icon (full-screen)","Mitsubishi (FX)":"Yes","Operation, max.":"90 %","Screen diagonal":"4.5 in","Unit switchover":"No","lifecycle_stage":"mature","Control elements":"Membrane keyboard","First/last value":"Yes","Menu tree editor":"Yes","Mitsubishi (MP4)":"Yes","Modicon (Modbus)":"Yes","Number of colors":"2; Black/white","Numeric keyboard":"Yes","Acoustic Feedback":"No","Angle of rotation":"No","Design of display":"STN","Device switchover":"Yes","IP (at the front)":"IP65","Limit value lines":"Yes","Message indicator":"No","Mounting position":"vertical","Number of recipes":"100","Other Bus Systems":"Yes","Recipe management":"Yes","Touch calibration":"No","Configuration tool":"WinCC flexible Compact Version 2004 or higher (to be ordered separately)","Icon (full screen)":"100","Number of messages":"1 000","Recording/Printing":"Alarms, report (shift report), hardcopy","Allen Bradley (DF1)":"Yes","Bureau Veritas (BV)":"Yes","Interfaces/bus type":"1x RS 232, 1x RS 422, 1x RS 485 (max. 12 Mbit/s)","Multi-key operation":"Yes","System messages HMI":"Yes","System messages PLC":"Yes","Hexadecimal Keyboard":"Yes","PPI (point-to-point)":"Yes","Acknowledgment groups":"Yes","Allen Bradley (DF485)":"Yes","Alphanumeric Keyboard":"Yes","Calculating functions":"Yes","EAC (formerly Gost-R)":"No","FM Class I Division 2":"Yes","Languages per project":"32","Number of system keys":"23","Number of user groups":"50","Number of user rights":"32","Open Platform Program":"No","Design as touch screen":"No; without","Mounting cutout, width":"135 mm","Number of bit messages":"1 000","OMRON (LINK/Multilink)":"Yes","Password export/import":"Yes","Telemecanique (ADJUST)":"No","Type of supply voltage":"DC","WinCC flexible Compact":"Yes","Backup/Restore manually":"Yes","Data records per recipe":"200","Entries per data record":"200","Germanischer Lloyd (GL)":"Yes","Height of housing front":"186 mm","Index of screen context":"No","Mounting cutout, height":"171 mm","Number of alarm classes":"32","Number of function keys":"8","WinCC flexible Advanced":"Yes","WinCC flexible Standard":"Yes","Connection to controller":"S5, S7-200, S7-300/400, TI 505, Win AC, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus), further non-Siemens drivers, see chapter \"System interfaces\"","Det Norske Veritas (DNV)":"Yes","Number of USB interfaces":"1","Number of bars per chart":"5","Permanent window/default":"Yes","WinCC Basic (TIA Portal)":"No","With software interfaces":"No","Number of analog messages":"1 000","Number of password fields":"0","STEP 7 Basic (TIA Portal)":"No","Start screen configurable":"Yes","Trace (operation archive)":"No","Transfer of configuration":"MPI/PROFIBUS DP, serial, USB, by means of external storage medium, automatic transfer recognition","Number of date/time fields":"0","Number of numerical fields":"1 000","Telemecanique (Uni-Telway)":"Yes; Only in combination with WinCC flexible","Weight (without packaging)":"0.5 kg","Width of the housing front":"150 mm","WinCC Comfort (TIA Portal)":"Yes","Number of RS 422 interfaces":"1","Number of RS 485 interfaces":"1","Starting current inrush I2t":"0.5 A²·s","WinCC Advanced (TIA Portal)":"Yes","Multimedia card/SD card slot":"combined","Polski Rejestr Statkow (PRS)":"No","MTBF backlighting (at 25 °C)":"100 000 h","Number of configurable images":"500","Suitable for safety functions":"No","Memory available for user data":"1 000 kbyte","Nippon Kaiji Kyokai (Class NK)":"Yes","Number of variables per device":"1 000","Number of variables per screen":"30","Pre-Installed Operating System":"Windows CE","Process value display (output)":"Yes","Customer-specific configuration":"No","Number of alphanumerical fields":"1 000","WinCC Professional (TIA Portal)":"Yes","Number of characters per message":"80","Number of text lists per project":"300","STEP 7 Professional (TIA Portal)":"No","American Bureau of Shipping (ABS)":"Yes","Current consumption (rated value)":"0.2 A","Lloyds Register of Shipping (LRS)":"Yes","Number of function keys with LEDs":"4","Supports protocol for PROFINET IO":"No","Number of characters per info text":"320","Number of online/runtime languages":"5","Telegram message procedure Alarm S":"Yes","User-Definable Label Membrane Keys":"Yes","Number of entries per graphics list":"0","Number of graphics lists per project":"0","Number of process values per message":"8","Process value default (input) possible":"Yes","Additional software components loadable":"Yes","Number of industrial Ethernet interfaces":"0","Monitoring function for battery and memory":"No","SIMATIC HMI MM memory card: Multi Media Card":"Yes","Alarm system (incl. buffer and acknowledgment)":"Yes","System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... )":"No","Maximum Permissible Angle Of Inclination Without External Ventilation":"80°"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$477.77","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d6f829390e446857010ef9310782176e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=68784&mlfb=6AV6641-0CA01-0AX1","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AV6641-0CA01-0AX1/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AV6641-0CA01-0AX1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AV6641-0CA01-0AX1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}