{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AV6644-0AC01-2AX1","brand":"Siemens","brandSlug":"siemens","productSlug":"6AV6644-0AC01-2AX1","canonicalUrl":"https://aoctrl.com/siemens/6AV6644-0AC01-2AX1","factsUrl":"https://aoctrl.com/api/mcp/products/6AV6644-0AC01-2AX1","rawCanonicalId":null},"summary":{"shortDescription":"The new part, as of 01.01.2015, is blocked for delivery. Spare part can continue to be purchased as required, but price may deviate from new part. Further information under SIMATIC current entry ID: 109486162. For questions, the familiar contact persons are available to you. SIMATIC MP 377 19\" Touch Multi Panel, Windows CE 5.0 19\" color TFT display 12 MB configuration memory configurable from WinCC flexible 2007","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":"NRND","categoryPath":["HMI Operator Interfaces"],"specifications":{"S5":"Yes","CSV":"Yes","MPI":"Yes","Hide":"Yes","Max.":"60 °C","Min.":"-20 °C","Type":"Hardware clock, battery backup, synchronizable","Icons":"2 000","Lines":"1","cULus":"Yes","Change":"Yes","Cyclic":"Yes","MODBUS":"Yes","Return":"Yes","S7-200":"Yes","TCP/IP":"Yes","TI 505":"Yes","Animate":"Yes","CE mark":"Yes","CF card":"Yes","Methods":"Trend / profile","S7-1200":"Yes","S7-1500":"Yes","Ethernet":"Yes","PROFIBUS":"Yes","PROFINET":"Yes","Hard disk":"Yes","IP (rear)":"IP20","Libraries":"Yes","PROFIsafe":"No","Retentive":"Yes","Tolerance":"Yes","S7-300/400":"Yes","Simulation":"Yes","Structures":"Yes","USB memory":"Yes","ATEX Zone 2":"No; certificate no longer available as of 1 October 2020","EtherNet/IP":"Yes","Help system":"Yes","PPI network":"Yes","PROFIBUS DP":"Yes","Peripherals":"Printer, card reader, barcode reader","Sm@rtServer":"Yes","System keys":"No","UL approval":"Yes","ATEX Zone 22":"No; certificate no longer available as of 1 October 2020","Bit messages":"Yes","CF card slot":"1x CF card slot","Clean screen":"Yes","Color change":"Yes","Limit values":"Yes","Multiplexing":"Yes","NEMA (front)":"NEMA 4, NEMA 12 (when installed)","TAB sequence":"Yes","Task planner":"Yes","Text objects":"30 000 text elements","X/Y movement":"Yes","Color display":"Yes","Overall depth":"75 mm","Recipe memory":"128 KB integrated Flash, expandable","Delta transfer":"Yes","GE-Fanuc (SNP)":"Yes","Initial values":"2 048","Status/control":"With SIMATIC S7","Synchronizable":"Yes","Type of memory":"Flash / RAM","Analog messages":"Yes","Dynamic Objects":"Diagrams, bar graphs, sliders, analog display, invisible buttons","Graphics object":"Bit maps, icons, vector graphics","Memory location":"CF card, SD/MMC card, Ethernet, USB memory stick","Message archive":"Yes","Mitsubishi (FX)":"Yes","Operation, max.":"90 %","Screen diagonal":"19 in","Size of archive":"depending on free memory on ext. card/stick or on free hard disk space via network drive","lifecycle_stage":"mature","Control elements":"Touch screen","First/last value":"Yes","Mitsubishi (MP4)":"Yes","Modicon (Modbus)":"Yes","Number of colors":"65 536","Numeric keyboard":"Yes","Type Date & Time":"2 048","Archiving methods":"Sequential log, circular log, alarm log, process value archive","Design of display":"TFT","Device switchover":"Yes","IP (at the front)":"IP65","Limit value lines":"Yes","Message indicator":"Yes","Number of recipes":"500","Online evaluation":"via trends","Other Bus Systems":"Yes","Recipe management":"Yes","Touch calibration":"Yes","Configuration tool":"WinCC flexible Standard Version 2007 or higher (to be ordered separately)","Number of messages":"4 000","Recording/Printing":"Alarms, report (shift report), color print, hardcopy","Sequential archive":"Yes","Short-term archive":"Yes","Using Trend Curves":"Yes","Allen Bradley (DF1)":"Yes","Data storage format":"CSV file, readable, e.g. with MS Excel, MS Access","External Evaluation":"readable, e.g. with MS Excel, MS Access, etc.","Interfaces/bus type":"1x RS 422, 1x RS 485, 2x Ethernet (RJ45)","Number of variables":"2 000","System messages HMI":"Yes","System messages PLC":"Yes","Hexadecimal Keyboard":"Yes","PPI (point-to-point)":"Yes","Allen Bradley (DF485)":"Yes","Alphanumeric Keyboard":"Yes","Calculating functions":"Yes","FM Class I Division 2":"Yes","Languages per project":"32","Number of system keys":"0","Number of user groups":"50","Number of user rights":"32","Open Platform Program":"Yes","Process value archive":"Yes","Design as touch screen":"Yes; analog, resistive","Mounting cutout, width":"449 mm","Number of bit messages":"4 000","OMRON (LINK/Multilink)":"Yes","Password export/import":"Yes","Type of supply voltage":"DC","WinCC flexible Compact":"No","Backup/Restore manually":"Yes","Data records per recipe":"1 000","Entries per data record":"1 000","Height of housing front":"400 mm","Mounting cutout, height":"379 mm","Number of alarm classes":"32","Number of function keys":"0","WinCC flexible Advanced":"Yes","WinCC flexible Standard":"Yes","Active power input, typ.":"60 W","Connection to controller":"S5, S7-200, S7-300/400, TI 505, Win AC, PC (TCP/IP), SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus), further non-Siemens drivers, see chapter \"System interfaces\"","Number of USB interfaces":"2; Up to 1 GB respectively","Number of bars per chart":"20","Permanent window/default":"Yes","WinCC Basic (TIA Portal)":"No","With software interfaces":"No","Number of analog messages":"200","Number of password fields":"2 048","STEP 7 Basic (TIA Portal)":"No","Start screen configurable":"Yes","Transfer of configuration":"MPI/PROFIBUS DP, serial, USB, Ethernet, by means of external storage medium, automatic transfer recognition","Number of date/time fields":"400","Number of numerical fields":"2 048","Telemecanique (Uni-Telway)":"Yes","Weight (without packaging)":"7.7 kg","Width of the housing front":"483 mm","WinCC Comfort (TIA Portal)":"Yes","Number of RS 422 interfaces":"1","Number of RS 485 interfaces":"1","WinCC Advanced (TIA Portal)":"Yes","Multimedia card/SD card slot":"1x Multimedia Card slot, up to 128 MB","MTBF backlighting (at 25 °C)":"50 000 h","Number of archives per device":"50","Number of configurable images":"500","Number of entries per archive":"50 000","Number of objects per project":"2 000","Memory available for user data":"12 288 kbyte","Number of variables per device":"4 096; Configuration with WinCC flexible 2008 and higher","Number of variables per screen":"400","Pre-Installed Operating System":"Windows CE","Process value display (output)":"Yes","Number of alphanumerical fields":"300","Number of entries per text list":"256","WinCC Professional (TIA Portal)":"Yes","Number of characters per message":"80","Number of text lists per project":"500","STEP 7 Professional (TIA Portal)":"No","Current consumption (rated value)":"2.5 A","Number of function keys with LEDs":"0","Supports protocol for PROFINET IO":"Yes","Number of characters per info text":"70","Number of online/runtime languages":"16","Number of signal lamps per project":"400","Telegram message procedure Alarm S":"Yes","Number of entries per graphics list":"256","Number of graphics lists per project":"500","Number of process values per message":"8","Number of status switches per project":"400","Number of measuring points per project":"50","Number of visible switches per project":"400","Process value default (input) possible":"Yes","Additional software components loadable":"Yes","Number of selector switches per project":"400","Number of industrial Ethernet interfaces":"2","Limit class A, for use in industrial areas":"Yes","Monitoring function for battery and memory":"Yes","SIMATIC HMI MM memory card: Multi Media Card":"Yes","Alarm system (incl. buffer and acknowledgment)":"Yes","SIMATIC HMI SD memory card: Secure Digital memory card":"Yes","System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... )":"Yes","Maximum Permissible Angle Of Inclination Without External Ventilation":"35°"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$4,152.90 – $4,778.00","priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/2984d642392a02fd1938b9b6b58408e9.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=481524&mlfb=6AV6644-0AC01-2AX1","alternativesUrl":"https://aoctrl.com/api/mcp/products/6AV6644-0AC01-2AX1/alternatives.json"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AV6644-0AC01-2AX1","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AV6644-0AC01-2AX1 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-09-02T08:15:54.622Z","lastPublished":"2026-09-02T08:15:54.622Z","indexable":true}}