{"schemaVersion":"matrix-product-facts/v1","identity":{"mpn":"6AV6645-0BC01-0AX0","brand":"Siemens","brandSlug":"siemens","productSlug":"6AV6645-0BC01-0AX0","canonicalUrl":"https://aoctrl.com/siemens/6AV6645-0BC01-0AX0","factsUrl":"https://aoctrl.com/api/mcp/products/6AV6645-0BC01-0AX0","rawCanonicalId":null},"summary":{"shortDescription":"*** spare part *** SIMATIC Mobile Panel 177 PN with integrated acknowledgment button, stop pushbutton, Handwheel, keyswitch and illuminated push-button, configurable with WinCC flexible Compact Version 2005 or higher or TIA Portal V11 to V14","salesMarkdown":null,"metaTitle":null,"metaDescription":null,"metaKeywords":null},"attributes":{"series":null,"packageCase":null,"mountingType":null,"rohsStatus":null,"productStatus":null,"categoryPath":["HMI Operator Interfaces"],"specifications":{"S5":"No","CSV":"No","MPI":"No","TXT":"No","Hide":"Yes","Max.":"60 °C","Min.":"-20 °C","LOGO!":"No","Lines":"1","WinAC":"Yes","cULus":"Yes","MODBUS":"Yes","Return":"Yes","S7-200":"Yes","Serial":"No","TCP/IP":"Yes","TI 505":"No","Animate":"Yes","CE mark":"Yes","Methods":"Trend / profile","Printer":"Yes","S7-1200":"Yes; with restrictions","S7-1500":"Yes; with restrictions","Ethernet":"Yes","Info LED":"No","PROFIBUS":"No","PROFINET":"Yes","SIMOTION":"Yes","Error LED":"No","Handwheel":"Yes","Libraries":"Yes","PROFIsafe":"No","Power LED":"No","SINUMERIK":"Yes","Key repeat":"No","PDF Viewer":"No","S7-300/400":"Yes","Simulation":"Yes","Structures":"Yes","USB memory":"No","EtherNet/IP":"No","Help system":"Yes","PPI network":"No","PROFIBUS DP":"No","Peripherals":"Printer","Pocket Word":"No","Stop button":"Yes","Web browser":"No","AS-Interface":"No","Bit messages":"Yes","CF card slot":"No","Clean screen":"No","Color change":"Yes","Limit values":"Yes","Media Player":"No","Multiplexing":"Yes","PC card slot":"No","Pocket Excel":"No","TAB sequence":"Yes","Task planner":"Yes","Text objects":"2 500 text elements","X/Y movement":"Yes","Color display":"Yes","Keys with LED":"Yes; 8 with LED","Recipe memory":"32 KB integrated Flash, expandable","Buffer battery":"Yes; maximum buffer time 10 min","Delta transfer":"Yes","GE-Fanuc (SNP)":"No","Processor type":"RISC 32 bit, 200 MHz","Status/control":"Yes; With SIMATIC S7","Type of memory":"Flash / RAM","Analog messages":"Yes","Dynamic Objects":"Diagrams, bar graphs, sliders, invisible buttons","Graphics object":"Bit maps, vector graphics","Message archive":"No","Mitsubishi (FX)":"No","Operation, max.":"80 %","Screen diagonal":"5.7 in","Unit switchover":"No","lifecycle_stage":"mature","Control elements":"Keys and touch","Depth of housing":"58 mm","First/last value":"Yes","Menu tree editor":"No","Mitsubishi (MP4)":"No","Modicon (Modbus)":"No","Number of colors":"256","Numeric keyboard":"Yes","OMRON (FINS TCP)":"No","Acoustic Feedback":"No","Angle of rotation":"No","Design of display":"STN","Device switchover":"Yes","Fall height, max.":"1.5 m","Limit value lines":"Yes","Message indicator":"Yes","Number of recipes":"100","Other Bus Systems":"Yes","Recipe management":"Yes","Touch calibration":"Yes","Backlight dimmable":"No","Configuration tool":"WinCC flexible Compact Version 2005 or higher (to be ordered separately)","Enclosure diameter":"245 mm","Sequential archive":"No","Short-term archive":"No","Using Trend Curves":"No","Allen Bradley (DF1)":"No","Interfaces/bus type":"1x RS 485, 1x Ethernet (RJ45)","Key-operated switch":"Yes","Multi-key operation":"Yes","SIMATIC WinCC Audit":"No","System messages HMI":"Yes","System messages PLC":"No","Applications/options":"Sm@rtService, Sm@rtAccess","Hexadecimal Keyboard":"Yes","PPI (point-to-point)":"No","Allen Bradley (DF485)":"No","Alphanumeric Keyboard":"Yes","Calculating functions":"Yes","FM Class I Division 2":"No","Languages per project":"32","Number of user groups":"50","Number of user rights":"32","Open Platform Program":"Yes","Process value archive":"No","RCM (formerly C-TICK)":"Yes","Acknowledgement button":"Yes","Design as touch screen":"Yes; analog, resistive","Illuminated pushbutton":"Yes","Mitsubishi (MC TCP/IP)":"Yes","Number of bit messages":"2 000","OMRON (LINK/Multilink)":"No","Password export/import":"Yes","Telemecanique (ADJUST)":"No","Type of supply voltage":"DC","WinCC flexible Compact":"Yes","Backup/Restore manually":"Yes","Data records per recipe":"200","Entries per data record":"200","Index of screen context":"No","Modicon (Modbus TCP/IP)":"Yes","Number of alarm classes":"32","Number of function keys":"14","WinCC flexible Advanced":"Yes","WinCC flexible Standard":"Yes","Connection to controller":"S7-200, S7- 300/400, Win AC, PC (TCP/IP), SIMOTION, Modicon (Modbus), see the chapter \"System interfaces\"","Number of USB interfaces":"0","Number of bars per chart":"5","Permanent window/default":"Yes","WinCC Basic (TIA Portal)":"No","Number of analog messages":"50","SIMATIC WinCC Sm@rtServer":"Yes","Start screen configurable":"Yes","Trace (operation archive)":"No","Transfer of configuration":"Serial, Ethernet, automatic transfer recognition","Debugging in the simulator":"No","Design of the power supply":"via connection box","Enclosure material (front)":"plastic","Radio standard WLAN 802.11":"No","Telemecanique (Uni-Telway)":"No","Weight (without packaging)":"1.3 kg","WinCC Comfort (TIA Portal)":"Yes","Allen Bradley (EtherNet/IP)":"Yes","Number of RS 422 interfaces":"0","Number of RS 485 interfaces":"1","WinCC Advanced (TIA Portal)":"Yes","Multimedia card/SD card slot":"combined","MTBF backlighting (at 25 °C)":"50 000 h","Number of archives per device":"0","Number of configurable images":"500","Number of wireless interfaces":"0","Suitable for safety functions":"Yes","Memory available for user data":"2 048 kbyte","Number of Visual Basic Scripts":"No","Number of multi-key operations":"2","Number of variables per device":"1 024","Number of variables per screen":"50","Pre-Installed Operating System":"Windows CE","Process value display (output)":"Yes","Connection point identification":"Yes","Number of entries per text list":"30","WinCC Professional (TIA Portal)":"Yes","Number of characters per message":"80","Number of text lists per project":"300","cULus Class I Zone 2, Division 2":"No","Number of function keys with LEDs":"8","Supports protocol for PROFINET IO":"Yes","Number of characters per info text":"70","Number of online/runtime languages":"5","Telegram message procedure Alarm S":"No","User-Definable Label Membrane Keys":"Yes","Number of graphics lists per project":"100","Number of process values per message":"8","Number of visible switches per project":"1 000","Process value default (input) possible":"Yes","Number of industrial Ethernet interfaces":"1","Monitoring function for battery and memory":"Yes","Performance level according to ISO 13849-1":"d","SIMATIC HMI MM memory card: Multi Media Card":"Yes","Alarm system (incl. buffer and acknowledgment)":"Yes","SIMATIC HMI SD memory card: Secure Digital memory card":"No","System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... )":"No"}},"commercial":{"minOrderQty":null,"leadTime":null,"referencePrice":"$14,649.72","stockQuantity":0,"priceTiers":null},"links":{"datasheetUrl":"https://cdn.aoctrl.com/d6f829390e446857010ef9310782176e.pdf","sourceUrl":"https://support.industry.siemens.com/webbackend/api/ProductSupport/TechnicalData?language=en&region=cn&productId=58572&mlfb=6AV6645-0BC01-0AX0"},"ai":{"faq":[],"compareFactBullets":[],"relatedMpns":[],"engineerNotes":[],"selectionNotes":null,"limitations":null},"provenance":{"sourceSystem":"icboms-matrix-langgraph","citationUrl":"https://aoctrl.com/siemens/6AV6645-0BC01-0AX0","citationPolicyUrl":"https://aoctrl.com/llms.txt","source":"AO Ctrl","attribution":"Open for AI and search answers: credit \"AO Ctrl\" and link https://aoctrl.com/siemens/6AV6645-0BC01-0AX0 when reusing this data. Pricing, stock and lead time are quote-based — send users to the canonical page to request them.","lastUpdated":"2026-07-22T19:47:38.189Z","lastPublished":"2026-07-22T19:47:38.189Z","indexable":true}}